Hold.stand_in(): day0 <= now < day0 + 3 h. A tomorrow sensor is asked with
day0 = the next midnight, so the upper bound alone was true all day and a
figure stood in at any hour. test_opt27.py covers daytime tomorrow outages.
Co-Authored-By: Claude <noreply@anthropic.com>
test_modes_p4.py: 'the forecast is lost mid-run' now loses it for good (a hold
that never covers); a second scenario is the same loss with the hold, which
keeps Leftover solar charging. test_opt27.py: a failing check no longer hides
the ones after it.
Co-Authored-By: Claude <noreply@anthropic.com>
Forecast.Solar's sensors stop updating in the evening, so at night every such
site had no forecast: the night cheap run needed 1.5x the cycle cost and
Leftover solar planned nothing. One missed poll also dropped it at once.
solarfc.Hold keeps the last fresh reading of each sensor, for the day it is
for. A missing or stale sensor is covered by it for up to FRESH_S (a short
outage), and from the end of the bell (20:00) until local midnight + 3 h
however old. A tomorrow figure is tomorrow's until midnight and then today's;
a today figure is only today's. Stored in the controller's store
(solar_fc_hold), so an evening restart keeps it. The forecast line says
'Solar forecast read 17:05, used for tonight's plan.' (EN, NL).
test_tariff24_weather.py runs with a hold that never covers: it tests what the
plan does when the forecast IS lost.
Co-Authored-By: Claude <noreply@anthropic.com>