Commit Graph
7 Commits
Author SHA1 Message Date
glenn schrooyenandClaude 50b567d6d1 OPT-27: the night plan keeps the last fresh solar forecast
Forecast.Solar's sensors stop updating in the evening, so at night every such
site had no forecast: the night cheap run needed 1.5x the cycle cost and
Leftover solar planned nothing. One missed poll also dropped it at once.

solarfc.Hold keeps the last fresh reading of each sensor, for the day it is
for. A missing or stale sensor is covered by it for up to FRESH_S (a short
outage), and from the end of the bell (20:00) until local midnight + 3 h
however old. A tomorrow figure is tomorrow's until midnight and then today's;
a today figure is only today's. Stored in the controller's store
(solar_fc_hold), so an evening restart keeps it. The forecast line says
'Solar forecast read 17:05, used for tonight's plan.' (EN, NL).

test_tariff24_weather.py runs with a hold that never covers: it tests what the
plan does when the forecast IS lost.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-30 18:54:41 +01:00
glenn schrooyenandClaude 1c9fefd9dd Sync 0.19: the Forecast tab extends a cheap run with control's gap (TARIFF-24)
UX-54's Forecast tab (release/1.0) re-plans tomorrow's cheap run as control
will, with the gap `required`. It still added the "no weather" x1.5 always,
while control (TARIFF-24, from master) drops it when a forecast is read. In
the UX-54 scenarios the tab asked 0.225 where control needs 0.15. It now asks
`arbitrage.weather_uncertainty(True, c.solar_fc)`, so the two agree again, as
they did on release/1.0 alone. Display only; no control change. The tab's
blocks in every UX-54 scenario, every 2 h, are identical to release/1.0.

test_ux54.py pins it (the old line fails it). The TARIFF-24 DECISIONS note
names the tab as the fourth place that reads the rule.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-30 08:11:42 +01:00
glenn schrooyenandClaude 995028bc5d OPT-23, OPT-28: the day plan counts the sun right, and the night charge covers the expensive-hour shortfall
checks / unit (pull_request) Successful in 55m9s
infra-pin / fresh (pull_request) Successful in 1s
OPT-23: a state-only forecast is read from now for every span
(Forecast.between since=), so the plan's per-hour sun adds up to the day's
figure, today and tomorrow. Hourly splits are unchanged. The Forecast tab
reads spans the same way.

OPT-28: a Leftover solar battery buys, from the floor, the sum over the
expensive hours of max(0, house - trust x sun), / EFF. Several Leftover
solar batteries hold it together by capacity, the ceiling passes the rest
on, and what none can hold is said (Plan.uncovered_kwh). Home's grid block,
the Batteries line and the mode help (EN + NL) say the level, what it
covers, and that Leftover solar buys only what the sun will not give.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-29 21:02:18 +01:00
glenn schrooyenandClaude 4256bd3eda UX-54 round 4: modes off reads tomorrow at Home's count, no relabel in the walk
checks / unit (pull_request) Successful in 48m51s
infra-pin / fresh (pull_request) Successful in 2s
Modes off has no curve (no forecast is read, no house profile kept), so
dayview._levels() never ran there and tomorrow's legs were drawn from the
bound. homeview.trade_runs(ahead=f) now reads each leg at f(name, kind,
start), as mode_runs() does: no give while the emptiest battery is at the
floor, each share sized from that level. dayview._counted() gives a give
the level by Home's own count (the level now, plus what the blocks before
it put in, less what they take out); a charge is read from the floor,
because a full battery covers the house before the cheap hour.

The battery line says a give is planned when one is and the battery has
no give block, also with modes off.

test_ux54.py: the modes-on walk no longer relabels a GIVE role at the
floor; it asks control's own discharge envelope (packshare.envelope())
with each pack's cut-out at the floor. The peak-guard 20 % case asserts
the curve is at the floor at the 17:00 give start. A modes-off walk on a
cloudy day (arbitrage.decide() with the cycle's inputs, the packs moved by
what control does and by the house), cases A-D: control charges and gives
in exactly the quarters the tab has a block. trade_runs(ahead=f) unit
check. _stops() ends a give block where the level the tab shows is at the
floor (LEVEL_DP).

No decision, command, timing or option key changes.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-27 03:06:12 +01:00
glenn schrooyenandClaude 5ab8622265 UX-54 round 3: tomorrow's blocks last as long as control acts, give blocks checked at run start
checks / unit (pull_request) Successful in 48m22s
infra-pin / fresh (pull_request) Successful in 1s
- Tomorrow's grid block is drawn to where control stops charging. A cheap run
  is sized for all batteries together; a slower one is still below
  `charge_to()` when it ends and control plans the next cheap slots. The tab
  asks `modetrade.energy()` and `priceruns.plan()` with the packs at the
  curve's level and extends the run, so the curve charges as long.
- Each battery's block ends where it is at its own level (grid) or at the
  floor (give). The curve puts a point where a battery reaches its charge
  level inside a step.
- `homeview.mode_runs(ahead=f, rp=...)` reads each block at the level the
  curve has when it starts, with Home's own filter and MIN_KWH: no give block
  at the floor, no grid block at the planned level. Home never passes either.
- `no_tomorrow` names the hour from `solarfc.BELL_FROM_H`, where the curve
  stops.
- test_ux54.py part 7 compares control (`_mode_roles()` every 15 minutes) with
  the tab with no tolerance, and adds the cloudy / floor case.

No decision, command, timing or option key changes.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-27 00:53:58 +01:00
glenn schrooyenandClaude 75195f7073 UX-54 round 2: tomorrow's blocks where control will act, trust as the plan counts it, strings
checks / unit (pull_request) Successful in 48m25s
infra-pin / fresh (pull_request) Successful in 1s
F1: tomorrow's blocks no longer depend on the battery's level now. Home sizes
a block from the level now (`room()`, `plan_need()` in mode_runs, the leg
sizing in trade_runs) and draws none when there is no room or energy. For a
day that has not started the builders take `ahead=True` (Home never passes
it): a charge is read from the floor, a give from the ceiling. A grid block is
then kept only where `modetrade.chargers()` would charge at the curve's level
when the run starts. The UX-53 gate is unchanged. Today still equals Home; a
give run in the plan with no block (empty battery) has its own sentence
instead of "No charge or give blocks planned".

F2: test_ux54.py part 7 walks the real `_mode_roles()` every 15 minutes
through tomorrow and compares the roles with the tab's blocks (modes on, the
peak gate, part-full batteries), and the control cycle's verdict at 07:00
(modes off).

F3: the curve counts spare solar as trust x max(0, sun - house), stored at
EFF, as `dayplan.plan()` does (10 kWh sun, 2 kWh house, 70 %: 5.32 kWh).

Strings: cycle, no_tomorrow, ahead, no_level, measured; new give_later.

No decision, command, timing or option key changes.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-26 22:48:48 +01:00
glenn schrooyenandClaude b6b2d1b184 UX-54: a Forecast tab with the sun, the house and each battery's level, per hour
checks / unit (pull_request) Successful in 48m29s
infra-pin / fresh (pull_request) Successful in 1s
A new tab beside Home and Batteries for today and tomorrow: the solar
forecast, the solar measured so far, the house's expected use and each
battery's expected level, with the plan's own charge and give blocks under it.

- Blocks are Home's: today's are the plan's `runs`, tomorrow's come from the
  same builders (`homeview.runs_for()`), in the plan lines' words.
- The sun is what solarfc reads; a daily total is spread over the bell and the
  tab says so. The house is HouseProfile.estimator(), as the plan reads it.
- The level is new: `daycurve.curve()` gives each battery the role
  `modetrade.decide()` gives it and moves it hour by hour inside the plan's
  floor and ceiling. It is an estimate and counts on `solar_trust_pct`.
- Built on request (`GET forecast`), no Home Assistant call. Measured solar is
  kept per hour in memory from the reading control already takes.
- A part not known yet is a note: modes off, no forecast, learning, no
  forecast for tomorrow, a monthly cycle, no level, stopped, shadow.

No decision, command, timing or option key changes. Found, not changed:
`dayplan.plan()` over-counts a state-only forecast (DECISIONS/UX-54).

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-26 19:38:59 +01:00