Prepares the split of app/main.py's Controller into files by job, with no app
change. tools/main_files.py gives a test the text and the AST of main.py plus
the files split from it, and `live`, which sets a global in every file whose
functions read it (and raises when none does). Tests that read main.py's
source, and tests and replay tools that patch a main global (datetime,
compute, resolve, _mono, WRITE_BUDGET_S, ...), go through it, so they pass on
this layout and on the split one. test_split_patches.py fails when a test or
tool patches an app.main attribute that main.py no longer reads, or that
another file also reads. tools/maint21_same_ast.py proves every function,
method and module-level assignment of main.py at the base is found unchanged
in its new file.
Co-Authored-By: Claude <noreply@anthropic.com>
The 0 W of shutdown and of the Stop button now waits (bounded, 2 s) for a
write already on its way to the same unit, for every driver, GoodWe included.
Once shutdown has begun, cycle, heartbeat and safety-stop writes are dropped
right before the write is created. One shared wait (_await_inflight) serves
the 0 W and SMA-10's _release_last.
Co-Authored-By: Claude <noreply@anthropic.com>
The NL default for a hand-back driver without words (handback._BACK_NL) was
changed to "de eigen sturing" in round 2 at the PR #239 review's request
(comment 2495: the article as in the generic clause). The brief does not name
it, so DECISIONS now says where it came from and a test checks the exact Dutch
sentence. No app code change.
Co-Authored-By: Claude <noreply@anthropic.com>
When control takes the unit again, release_fails, release_retry_at and
release_zero_sent are reset, so the next Stop is a new streak with its own one
0 W, error line and event. Tests: a streak that Start interrupts without a
recovery; a driver that overrides release_fallback(). _BACK_NL "de eigen
sturing" (round 2) is kept.
Co-Authored-By: Claude <noreply@anthropic.com>
When release() fails (False, raises or hangs past RELEASE_BUDGET_S) the unit
gets one bounded write(0) through the new Driver.release_fallback() hook
(default write(0)), then nothing more, so the inverter's own fallback timer is
not reset. The release is retried once per heartbeat, not on every idle
write. One error line and one action-log event per failure streak, one line on
recovery. Dutch default "terug naar de eigen sturing". DECISIONS says what a
unit is left at.
test_messages.py: the RELEASE_BUDGET_S data entry is gone again (the line
that needed it is gone).
Co-Authored-By: Claude <noreply@anthropic.com>
A driver now says whether its release() hands the inverter back
(Driver.hands_back; GoodWe is False, so release() stays write(0) and the
Controller never calls it). command_site_release() sits next to
command_site_zero(): the Stop button and shutdown() (so SIGTERM, restart,
control task death and a late config refusal) hand a hand-back unit back,
once, and zero every other unit as before. Safety stops and refusals still
hold 0 W for every unit. Shadow mode releases a hand-back unit. After a
release nothing is written to the unit (heartbeat and cycle included) until
control starts again. release() is bounded by RELEASE_BUDGET_S (= the write
budget), runs concurrently per unit, and a raising or hanging release on one
unit does not stop the others.
The "set to 0 W" sentences for Stop, restart, shadow mode and the stopped
banner are built from the roster (app/handback.py, EN and NL, words from the
driver); a GoodWe-only roster keeps every old literal. A handed-back unit
shows "Back under <its control>" on Home.
Existing test edited: test_messages.py (two classification entries for the
CRITICAL line that moved into a roster builder, and the new release bound).
Co-Authored-By: Claude <noreply@anthropic.com>