After its own phase select (taken, or with a late read-back), Solar ends the
sequence with the lower of the currents for the new phases and the phases the
charger reports, and keeps the plan on them; the old phases' current comes
back only when no select went out (EV-28's cap). Rows: T19/T33 settle write
refused or ignored once and select confirmed late; an exit after a given-up
write; shutdown in Off with the 0 A owed; Stop with a refused 0 A and another
writer. NoCharger.write_current takes took_s; ev_mode_start text names C1;
NL solar_hold wording.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
C1: an own 0 A not yet read back is kept with the mode; a start in Off with
it writes the 0 A (retried), without it nothing; a start that will not write
warns once when the charger still has the add-on's current. C6: Solar's 30 s
gate also counts from Manual's latest write. C9: an exit also owes its 0 A
when the read-back shows Solar's own value. Rows for C5 and C8 too.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
T4: battery A's power missing, NaN or unavailable, for one cycle (no
write) and for 400 s (no spare, the current held, 0 A at 300 s).
T21 (a): car_cycle on the same projection, guard and reading gives the
same car figure, explains and over in Solar and Manual.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
Solar as a second writer next to Manual (carmode.SolarPlan, SolarWriter on
ManualWriter's one write site, safe phase sequence and other-writer watch):
signed spare, Batteries first on the batteries' ratings, the margin, whole
amps rounded down, the 30 s / 1 A rule, start and pause dwells, auto phases,
a one-phase car. Every way out ends at 0 A, retried by EV-04's rule; at
shutdown before the inverters, three tries inside 15 s (D3); start-up and a
returning charger or HA write 0 A first (D2); never over another writer's
hold. The peak guard treats a Solar car as a Manual car (D1 wording). Solar
kWh sensor and card line; select.goodwe_car_sun_first; ev_margin_w,
ev_start_min, ev_pause_min with config, validator, translations, DOCS,
DECISIONS and CHANGELOG.
Checks: test_ev20.py, test_ev20_exits.py, test_ev20_writers.py,
test_ev20_guard.py, test_ev20_long.py, test_ev20_long_car.py,
test_ev20_fuzz.py (harness tools/ev20_sun.py, ev20_kit.py, ev20_day.py);
test_ev03/test_ev04 no longer use Solar as the refused example.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w