glenn schrooyenandClaude 06339a2446 OPT-20: a refusal probe asks only PROBE_W, not the whole trade
checks / unit (pull_request) Failing after 40m47s
infra-pin / fresh (pull_request) Successful in 1s
The probe's trade was sized at the probing battery's rating. Its SAFETY-73
pin held 200 W of that, and the allocator put the rest on a battery with no
mode range (one in a maintenance phase): TEST-23 OPT-15 g7, -2300 W on A in
its maintenance charge for 34 s, grid 3100 W.

modetrade.decide() now asks PROBE_W for the probing battery plus what the
other chargers would have had without the probe; size() adds the probe on top
of their share, or files PROBE_W exactly, or nothing. _mode_trade() carries
the pin only on the ticks it is filed, so the window's first and last cycle
do not move another battery's share either. Modes off and modes on with no
probe are unchanged (bf9019e digests). Tests: test_opt20.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-15 13:08:59 +02:00
glenn schrooyenandClaude 065792aad3 Merge release/1.0 (e3e4ba6) into opt15-price-run-fixes
infra-pin / fresh (pull_request) Successful in 3s
checks / unit (pull_request) Successful in 39m30s
Conflicts (5 files, 9 hunks) resolved keeping both sides:
- p1.py: held_t (OPT-15) beside held_since (SAFETY-90).
- modetrade.py: chargers() takes targets (P4) and probe (OPT-15); decide()
  clears the chargers, a probing refuser included, while a battery drains
  (SAFETY-78); the docstring lists both rules.
- main.py: the roll goes into the SAFETY-90/91 projection chain
  (`_peak_proj`); the SAFETY-95 drain-tail grid_w keeps the run-edge hold on
  its other branch; the P4 forecast state and the hold state both stay.
- DOCS.md, DECISIONS: both lines kept, OPT-15 item refreshed.

Adaptations the merge needs:
- SAFETY-81 x F1: a rolled projection is not graded by the saturation alarm
  until the quarter's first sample, as the old edge tick was not, so a
  standing overload is still notified once per quarter.
- test_safety81, test_modes_p4: modes-on pins re-pinned (with a note), modes
  off pinned to e3e4ba6; test_price_run_fixes: identity pins on e3e4ba6,
  F1 reproduced at one inverter (SAFETY-91 already holds two), tests for the
  drain and the day plan against the probe.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-13 12:15:44 +02:00
glenn schrooyenandClaude Opus 5.5 b171ada894 Merge release/1.0 (SAFETY-78, #154) into opt11-p4-solar-forecast
checks / unit (pull_request) Successful in 23m54s
infra-pin / fresh (pull_request) Successful in 1s
Conflicts: modetrade.decide() takes both the day plan (targets) and
SAFETY-78's draining flag; the Why line keeps SAFETY-78's other_cycle
ahead of the plan's word (test added).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:37:09 +02:00
glenn schrooyenandClaude Opus 5.5 fbd884797d OPT-11 P4 review: Cheap hours ignores the plan; midnight-stale forecast; stricter ids
- Cheap hours only fills to the ceiling with or without a forecast, as the
  design (section 1) says. Skipping the sun's share cost 0.31 EUR on real
  2026 prices (29.72 against P3's 29.41) and saved nothing on the P3 set.
- A forecast reading from before local midnight is stale: until the
  integration refreshes, "left today" is still yesterday's 0 and
  "tomorrow" is really today.
- Forecast entity ids must be sensor.[a-z0-9_]+ (they go into the
  /api/states/<id> path).
- House profile: a stored day that is not a date, or is after today, is
  dropped instead of kept forever.
- Text: the forecast line says "for the rest of today"; the learning line
  no longer promises "tomorrow" (a plan needs one full day).
- Tests for four surviving review mutants (hour sample floor, the dear run
  after the cheap run, share by room, daytime use) and the fixes above.
- Replay tool: `--fc zero` (a forecast of no sun).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:08:47 +02:00
adminandClaude Opus 5.5 fae6681e19 OPT-15: price-run fixes (quarter edge, charge-end overshoot, refusal probe)
checks / unit (pull_request) Successful in 18m49s
infra-pin / fresh (pull_request) Successful in 1s
F1: with battery modes on, the peak guard projects the quarter `now` is in
even before its first P1 sample (PeakTracker.project(roll=True)), and only
a measured stop latches the period. The edge tick no longer reads "no
seconds left", so a charge is not stopped and latched at a quarter edge.

F2: after a run edge the loop is held at E until the meter shows the step
(EDGE_HOLD_S, longer while the battery still moves). The replay gained a
lag model (dead time, reading age, P1 debounce, 1 s cycles) that shows
TEST-23's overshoot without the hold.

F3: a charge refuser's SAFETY-73 probe inside a cheap run is a charger
pinned at PROBE_W, the others rest, so the probe actually runs.

Modes off stays byte-identical to 5a4cdc2 (new late-P1 identity scenarios).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 20:22:32 +02:00
Claude 5d27f8496f SAFETY-78: maintenance drain at N=2 no longer stalls
checks / unit (pull_request) Failing after 17m13s
infra-pin / fresh (pull_request) Successful in 2s
At two inverters the drain pins its pack and the site target is split
around the pin. Below the pin the other pack had to charge, the allocator
refused the opposite directions, and the site sat at 0 W with an ARBITER
line every cycle (house below or above the drain rate, or a grid charge).

main.py now files a site limit `drain` (lo = what the pin places, at
P_MAINTENANCE) at N>=2 while a pack drains, so the other pack only adds
power in the same direction. A drain that cannot give power waits with
one log line. With battery modes on, no grid charge while a pack drains,
and the other battery's card says why. N=1 is byte-identical.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 19:52:51 +02:00
Claude eb10537aee OPT-11 P4: solar forecast and day plan
A Home Assistant solar forecast (Forecast.Solar, Solcast or Open-Meteo
shapes) and the add-on's own hourly house use decide, before each cheap
run, whether the sun will fill each battery before the expensive hours.
Leftover solar then buys from the grid only the shortfall; Cheap hours only
skips the part the sun covers; Solar first never grid-charges. No, stale or
failed forecast: P3 option A exactly (12 digests pinned from 5a4cdc2).

Replay (16 recorded days, forecast errors from Elia's day-ahead BE solar):
year-earlier prices P4 19.15 vs P2 19.33 / option A 19.44 / old trade 18.14;
real 2026 prices P4 29.19 vs 32.26 / 32.01 / 31.40 EUR net.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 19:29:32 +02:00
Claude dev agent 6dab4ec16b OPT-11 P3, owner option A: selling off, Leftover solar takes solar only
checks / unit (pull_request) Successful in 15m12s
infra-pin / fresh (pull_request) Successful in 1s
Owner decision 2026-09-29. Selling is off until it can be judged on the price
the grid pays: packmode.SELLING_ENABLED = False makes read() answer
sell=False whatever the store holds, pack_sell is refused ("Selling is off
for now."), and the page has no selling switch; the sell code stays. Until
the P4 forecast, only Cheap hours only charges from the grid
(packmode.GRID_CHARGE_MODES); Leftover solar holds and gives in the
expensive runs. Help, Today and plan lines, DOCS and DECISIONS follow.
Replay, 16 days: Solar first + Leftover solar 19.44 EUR net (P2 19.33).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 10:42:58 +02:00
Claude dev agent 902524ae5e OPT-11 P3: price runs per battery
checks / unit (pull_request) Successful in 13m45s
infra-pin / fresh (pull_request) Successful in 1s
Cheap and expensive hours as runs of consecutive firm price slots
(priceruns.py); each battery's role per tick from its mode (modetrade.py):
grid charging for Leftover solar / Cheap hours only, never Solar first;
holding for the expensive runs; selling per battery (pack_sell) above the
spread and the floor. The site trade is sized inside the modes (loop bound)
and the peak guard's headroom; a run edge reseeds the loop. Cheap hours only
and selling are enabled on the Batteries screen and in the HA select
(appended). The site Why row no longer says "held back" when the peak limit
pushes power up (F2). Modes off: byte-identical to 7a00f12 on the trade path.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 02:37:44 +02:00