Commit Graph
2 Commits
Author SHA1 Message Date
ev03-devandClaude 678ea13895 EV-03 round 2: a missing car power is unknown, and mode3 E/F has a state
checks / unit (pull_request) Successful in 26m50s
infra-pin / fresh (pull_request) Successful in 2s
- CarTracker.car_w returns None when the current reading carries no power
  (power entity unavailable or in a non-power unit); it can no longer raise
  into the control cycle, /status or the MQTT values.
- mode3 E and F are the card state "fault" (EN and NL).
- chargersim gains fault().

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 12:02:17 +01:00
ev03-devandClaude 89a2eb0b74 EV-03: car charger seam, Alfen HA driver, read-only Car card
checks / unit (pull_request) Failing after 37m42s
infra-pin / fresh (pull_request) Successful in 2s
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 09:52:15 +01:00