Commit Graph
6 Commits
Author SHA1 Message Date
ev03-devandClaude af7e96e5e5 EV-03 round 4: a power entity that cannot be believed is unreachable
checks / unit (pull_request) Successful in 27m11s
infra-pin / fresh (pull_request) Successful in 2s
- every HA power unit is accepted and converted (mW, W, kW, MW), in the probe
  and in the reading
- a power entity that answers in another unit, with no unit, or not as a
  number makes the reading unavailable: after 30 s it is "Charger not
  reachable" (amber row, WARNING, notification after 5 min), with a Why that
  names the cause (EN and NL)

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 15:06:24 +01:00
ev03-devandClaude 918d44ab33 EV-03 round 3: the power entity is required and reads in W or kW
checks / unit (pull_request) Successful in 27m42s
infra-pin / fresh (pull_request) Successful in 1s
A charger with no usable power entity is refused as "not set up", like a
missing setpoint, read-back or state entity, so House and the house profile
behave as with no charger. An entity that is merely unavailable at probe time
is still the unreachable path. NL: help text "met rust", chip "Laadpaalstoring".

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 13:35:09 +01:00
ev03-devandClaude 89a2eb0b74 EV-03: car charger seam, Alfen HA driver, read-only Car card
checks / unit (pull_request) Failing after 37m42s
infra-pin / fresh (pull_request) Successful in 2s
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 09:52:15 +01:00
goodwe-agent c50e2279dd SAFETY-136: a gentler loop on a slow meter until the last move shows
checks / unit (pull_request) Successful in 26m18s
infra-pin / fresh (pull_request) Successful in 2s
On a meter whose readings come 4 s or more apart, the loop runs at half its
gain after a move of 150 W or more, until the meter has fallen by half of the
move or 2 cycles have passed. With readings 10 s late on a 5 s meter the export
falls 44 % over oven, kettle and hob, owner shape, steps; 1-2 s meters are
untouched.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 14:49:26 +01:00
glenn schrooyenandClaude 902da3f723 MAINT-21: comments only - trim restated notes, add DECISIONS pointers
checks / unit (pull_request) Successful in 25m17s
infra-pin / fresh (pull_request) Successful in 1s
No code change: tools/maint21_same_ast.py and tools/maint20_same_code.py HEAD~
both print OK, and the -OO code objects are the same.

- Trims 56 comment and docstring lines (2088 -> 2032) in app/main.py and the
  new files that only restated their MAIN-orchestration.md bullet, each cut to
  its first sentence and a pointer. What the cut comments said and the bullet
  did not is now in the bullet: why a SAFETY-02 latch is restored, why the
  SAFETY-30 site check is not armed at one inverter, the SAFETY-18 re-derive,
  the MAINT-05 one-config rule, the OPT-09 sizing rules, the "no plan" row,
  the 5 400 s age bound, and the guard being the only latch repair.
- Adds the missing DECISIONS pointers on the SMA-10, SAFETY-137 and SMA-2
  comments (FALLBACK_BUDGET_S, write_setpoint, _await_inflight,
  _release_last, the retry wait, the failed-release branch, release_zero_sent,
  the in-flight write, the stop_event hand-back, the SMA-2 read and driver).
- DECISIONS/SAFETY-32: the stale `main.py:932-936` now names
  Controller.pack_floor_soc.
- main.py's docstring and import block say where the Controller's parts are.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 00:41:34 +01:00
glenn schrooyenandClaude fb0730fe6f MAINT-21: app/ctl_inputs.py - Controller methods that read the inputs
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. InputsMixin: read_inputs, _read_unit, live_units and the other readers of the meter, packs, PV and forecast. tools/maint21_same_ast.py: OK.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-09 00:29:40 +01:00