- The peak limit's Why and plan block need a real power request (floor above
0 W), not a blind or floor-limited guard. An Off battery gets the peak
block only while it gives power. Why no longer says every battery gives.
- test_batteries_screen pins the fixture clock: unpinned it failed every
morning. New checks cover the trade and cycle filters, the blind guard and
an Off battery that A covers alone.
- Settings keeps only a picked view; a link to Installer is not remembered.
- Browser check: badges, unsaved change across views, locked value.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Batteries: one card per battery with On/Off, the mode list (cheap hours
and selling greyed out until OPT-11 P3), level, and Now / Today / Why
lines built in homeview.py. Replaces the OPT-11 P1 minimal cards and uses
the existing pack_use / pack_mode actions and store keys.
- An Off battery the peak limit still needs says so with its figure; no line
shows 0 W beside moving power (OPT-11 P1 test F2). Today says "Not planned
yet" until OPT-11 P3/P4.
- Home's plan leaves Off batteries out, except for the peak limit.
- Settings opens on Simple: the layout's simple fields with an applies chip
and a note, plus the battery switches and modes. Installer is one tap.
- English and Dutch words in app/ui_text; test_batteries_screen.py; browser
check tools/ux13_browser_check.py (CHECK=1 ux13_screenshots.sh); new and
changed screenshots only.
No control, allocator, arbiter or command module changed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
A battery's mode is a soft unit limit (source `mode`, P_MODE 35) kept
apart from the hard limits in pre_resolve(). The allocator applies it
only while the site target is decided at or below 35 (new
Resolution.deciding_priority), so the peak floor releases it and a mode
`hi` never meets the site `lo`. At N=1 resolve() applies the same rule
to the site target after stage 2. A mode range without 0 W is dropped
as a software fault, so REFUSE_SIGN stays unreachable from a mode.
compute() gets the loop bound (sum over live units of hard limits with
modes applied), so the loop never asks for watts no battery may give
and the saturation freeze never parks on them. While charging, Leftover
solar weighs 0 so Solar first fills first. Store keys pack_use and
pack_mode per battery, set by two new /action values; Off stops and
skips maintenance with a log line. Minimal Batteries cards (EN/NL).
Off by default (battery_modes_enabled); off, commands are byte-identical
to a5dddad at N=1 and N=2 (test_modes.py part 1).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- app/ui_text/nl.json and app/uitext.py: every page word in Dutch, English
fallback per key; the page picks by browser language. Home's sentences
move into ui_text `home_words`, so /status?lang=nl builds them in Dutch.
- test_ui_text.py: EN/NL key and placeholder parity, STYLE limits, jargon
lists for both languages, no inline details, untranslated Dutch caught.
Shared rules moved unchanged to tools/style_rules.py.
- tools/ux13_screenshots.sh/.py: DOCS screenshots from the demo fixtures in
headless Chromium; docs/img/ux13/. Battery modes (P3): no screenshot.
- "Other time windows": a list editor (ui.periods) that builds
static_profile and names bad times, empty prices, overlaps and gaps.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A new install names no inverter. When that is the startup gate's only
refusal, the add-on now serves the setup wizard in setup-only mode instead
of exiting 78. It builds no controller, MQTT client or meter task, its
HomeAssistant is read-only (every service call refuses before sending),
Controller refuses a read-only HomeAssistant, and /action answers 409.
Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md.
Wizard fixes from the UX-13 P4 test:
- F1: /config/validate converts what it can, so a conversion error blocks
its own step and the live checks still run; save 422 carries steps.
- F2: saves send the model the page opened (base); only keys this page
changed are written onto the blob stored now.
- A meter entity missing from Home Assistant is red on the last step.
- Step 1 says the reading went down after a skip that followed a fall.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
R1: first_start also needs a Store created at this boot (Store.fresh), so
old never-started sites (both TEST-23 add-ons, one in shadow) stay on Home.
R2: a kettle skip after a fall says on the last step that the reading went down.
R3: the shadow switch goes only on the model the wizard posts, never into V.
R4: Home Assistant not answering is red on the last step.
R5: meter + solar + battery below -300 W flags a reversed battery sensor.
R6: the live checks say what to change and where.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The Setup tab draws the Installer view's page model one step at a time,
from each field's `wizard` step in app/uilayout.py: meter (with the kettle
test), inverters and batteries, solar (optional), prices, peak limit
(battery modes: "comes in a later update", OPT-11), check and start.
It reuses P2's controls and saves through /config/validate and
/config/save. No route was added.
- First run: /config/model says `setup_needed` when the stored options name
no power request entity, or on a new install (no `setup_done` and no
`auto` in the Store, control not started). The page opens #setup only
when opened with no route. The wizard's save writes `setup_done`.
- Kettle test: GET ha/entities?entity= reads one entity now, in W. The
change decides: up keeps meter_invert off, down turns it on; a net or
import/export meter that goes down blocks the step with what to check.
- Last step: validate.setup_checks() beside the refusals: the meter reads,
each power request entity exists in HA (bad if not, SAFETY-77), battery
levels and power with direction, solar sign, prices. Saves with
shadow_mode on by default, then a confirmed restart naming the 0 W.
- P2 test finding (a): a stale save lists only the keys the other surface
moved (the blob handed out on open, by fingerprint, against stored now).
- test_setup.py; tools/ux13_wizard_blobs.py makes the 88 blobs the wizard
can save; all accepted by Supervisor 2026.08.0 AppOptions (offline).
- DECISIONS/UX-13-setup-wizard.md; DOCS "Setup, for a new install".
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
- Settings tab: the Installer view (app/static/settings.js), drawn from
app/uilayout.py through the new app/uipage.py: search, six collapsible
groups with "n to fix / n to check / n changed" badges and an "applies
after a restart" chip, radio cards, segmented choices, sliders with units
(the peak limit in kW), entity pickers with search and the live reading,
inverter cards, solar rows, locked measured values behind "Change", and
the add-on's refusals, warnings and info beside the field they name.
- Save path: the page posts its model to the existing config/validate and
config/save; uimodel turns it into options before the shipped validator,
so nothing it refuses is saved. No route added. A value equal to the
stored one is written as stored, so a save that changed nothing writes an
identical blob. Save bar, then the restart dialog that names 0 W.
- The region choice shows its preset year; Wallonia and Brussels are listed
as having no preset yet (TARIFF-22). "Classic settings" keeps /config.
- P1 test findings: (a) "Going to 0 W" until the last accepted power request
is 0 W; (b) the trade blocks and the price line name the feed's own points
("Lowest published price"), the hour bars say "hour average"; (c) the entity
list's WARNING gives a reason on a timeout.
- test_settings.py; test_home, test_haentities, test_uilayout extended.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
- Trade blocks: none on a battery with no room, no sale at a negative price
or while the emptiest battery is at arbitrage's floor, nothing when a
level is unknown. A give after a charge may use what the charge put in.
- The refusal line names the real reason: prices not published vs gap.
- The plan's peak line uses the guard's ceiling (this month's peak once
above the cap), as the peak card does.
- House below zero: 0 W inside the idle band, no figure beyond it.
- Price bars are "Low price" / "High price": the add-on trades in one hour.
- Control toggle: one request in flight at a time.
- test_home: the new cases; the house-sign mutation now goes red.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- app/static/{index.html,app.css,app.js}: tabs (Home, Batteries, Settings,
Setup), hash routes, phone bottom tabs, light/dark. Served inlined at "/";
the route list is unchanged, and every URL is relative.
- app/homeview.py: /status gains state, now, batteries, plan, attention,
month_peak and control beside the old fields. The plan is what the add-on
does today: the arbitrage verdict (the same plan.arbitrage() call as the
cycle), the monthly cycle, the peak limit, "follows the house".
- The Home plan chart has hover, tap and keyboard-focus tooltips: price bar =
hour and price; block = what, when, why, kWh and EUR.
- Region preset and year: in config/model (for P2) and on the Home price line.
- test_home.py; test_messages part 8 scans every Home sentence; STYLE plan line.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
- uimodel: editing a listed inverter keeps the stored flat keys, and a
region of "own" keeps a stored price_taxes_profile (both were dropped).
- haentities: a failed read also waits CACHE_S, so polls while Home
Assistant is down do not queue one 10 s read each.
- ui_text: the Flanders preset names its DSO, and the help says
Wallonia and Brussels have no figures yet. REGION_PRESETS cites the card.
- tests: decode of a reversed solar row, both kept keys, the backoff.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The foundation for the new settings page. No visible UI change.
- app/uilayout.py: screen -> group -> part -> field for every option in
config.yaml (67 fields, 11 derived, 0 hidden), with control, unit, display
scale, step, entity kind, show conditions, Simple/wizard placement and
"applies after a restart". Ranges stay in the schema, words in
translations and the new app/ui_text/en.json.
- app/uimodel.py: options_to_ui()/ui_to_options() for the derived keys (one
inverter vs the list, solar rows, static_profile from simple prices, a
year-stamped region preset for the levies figure, and an OPT-11 hook for
arbitrage_enabled that changes nothing yet). Unchanged derivations write
the stored values back, so the round trip is exact.
- validate.py: validate.Note, a warn/info tier. Each logged warning is also
a note when a list is passed; config_notes() adds checks that need live
data (missing entity, a kW sensor read as W, a limit below this month's
peak). /config/validate returns them as "notes". No refusal changed: 261
recorded validator calls, 0 differ (tools/ux13_validator_calls.py).
- GET ha/entities: Home Assistant's entity list for the picker, read through
hass.states(), cached 30 s, 10 s timeout. When HA is down it answers 200
with the old list marked old, or an empty list that says why.
- DECISIONS/UX-13-one-layout-table.md amends UX-02's "no option key in UI
code": keys may appear in uilayout.py and uimodel.py only, both tested.
- Tests: test_uilayout, test_uimodel (round trip over the recorded calls,
the TEST-23 option files and config.yaml defaults), test_haentities, a
warning-tier part in test_validate; test_messages scans notes and
ui_text; test_pv and test_selfconfig part 7 widened on purpose.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p