Claude 82dc77df62 EV-20 SPIKE-06 round: arm the stuck check on the pre-send reading; Solar restarts after its own 0 A under a stuck verdict
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Failing after 1h12m28s
SPIKE-06 option 2 (PM decision). The stuck check's baseline is the reading
before the send, for accepted and refused writes; it clears on any change
from it (3a17012's power rules removed), so the race cannot arm it (C10,
C11, C13). Frozen power under an accepted write is left to the energy meter
and the read-back cap (EV-13 T14/T17/T18 changed). Once Solar's own 0 A
stands, a stuck verdict no longer blocks the start rule (C12), at most
MAX_TRIES starts per verdict, then CHARGER_REFUSED until Solar is pressed.
Rows in test_ev20_rig.py section 6.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-23 17:03:18 +01:00
Claude 3a170127a3 EV-20 rig round 1: stuck check clears on the car's answer or a paused car; EV-36 first-sample rule
checks / unit (pull_request) Successful in 46m35s
infra-pin / fresh (pull_request) Successful in 2s
An accepted write keeps the car's power from the reading before the send
(begin_write); a later reading whose power differs from it, or that shows a
paused car (not charging, under PAUSED_W), clears the armed check. A refused
write's first sample after the send is not life by itself (EV-36). EV-13 T7/T8
and the refusal-window row get two-change variants so mutant M3 stays killed.
DECISIONS records the arming rule.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-23 15:16:41 +01:00
Claude 711c5f3627 EV-20 rig round 1: stuck check armed on the reading before the send; no amp ping-pong; ha_signed meter age
infra-pin / fresh (pull_request) Successful in 4s
checks / unit (pull_request) Failing after 1h11m9s
The stuck check's baseline is the signature of the latest reading taken
before the send (kept at begin_write), never one that arrived while the write
waited; a refused write's first post-send sample is its baseline (EV-36).
After a step down, a step back up needs UP_HYST_W past the boundary. Solar's
15 s meter-age gate applies only where the age measures arrival; on
ha_signed it is the source's meter_max_age_s. Rows in test_ev20_rig.py;
harness modes for the rig's interleave and an on-change meter.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-23 14:28:21 +01:00
Claude 9c82bc816a EV-20 review round 1: no 1-phase current on 3 phases after a select; rows for mE, mF, mC
checks / unit (pull_request) Successful in 32m26s
infra-pin / fresh (pull_request) Successful in 2s
After its own phase select (taken, or with a late read-back), Solar ends the
sequence with the lower of the currents for the new phases and the phases the
charger reports, and keeps the plan on them; the old phases' current comes
back only when no select went out (EV-28's cap). Rows: T19/T33 settle write
refused or ignored once and select confirmed late; an exit after a given-up
write; shutdown in Off with the 0 A owed; Stop with a refused 0 A and another
writer. NoCharger.write_current takes took_s; ev_mode_start text names C1;
NL solar_hold wording.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-23 00:34:24 +01:00
Claude 226e5a1e8b EV-20: Car Solar mode, spare sun to the car (charging only)
checks / unit (pull_request) Successful in 57m6s
infra-pin / fresh (pull_request) Successful in 3s
Solar as a second writer next to Manual (carmode.SolarPlan, SolarWriter on
ManualWriter's one write site, safe phase sequence and other-writer watch):
signed spare, Batteries first on the batteries' ratings, the margin, whole
amps rounded down, the 30 s / 1 A rule, start and pause dwells, auto phases,
a one-phase car. Every way out ends at 0 A, retried by EV-04's rule; at
shutdown before the inverters, three tries inside 15 s (D3); start-up and a
returning charger or HA write 0 A first (D2); never over another writer's
hold. The peak guard treats a Solar car as a Manual car (D1 wording). Solar
kWh sensor and card line; select.goodwe_car_sun_first; ev_margin_w,
ev_start_min, ev_pause_min with config, validator, translations, DOCS,
DECISIONS and CHANGELOG.

Checks: test_ev20.py, test_ev20_exits.py, test_ev20_writers.py,
test_ev20_guard.py, test_ev20_long.py, test_ev20_long_car.py,
test_ev20_fuzz.py (harness tools/ev20_sun.py, ev20_kit.py, ev20_day.py);
test_ev03/test_ev04 no longer use Solar as the refused example.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 20:31:26 +01:00
Claude 5ebd830966 EV-13 review: compare phase currents per phase; test a late read-back
checks / unit (pull_request) Successful in 26m23s
infra-pin / fresh (pull_request) Successful in 1s
A phase that drops out or comes back shifted the compressed current_a tuple and
read as life, so a frozen charger never armed. ChargerReading.phase_a keeps
L1/L2/L3 with None for a missing phase and the life test uses it.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 05:44:31 +01:00
Claude 1b39f1698a EV-13 router round 1: lapse a refusal's window on unavailable readings; T27, T28 and the N-ids
checks / unit (pull_request) Successful in 31m40s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 03:56:53 +01:00
Claude c25877fea4 EV-13: a refused current write arms the stuck check only when the charger shows no life
A refused write on a live charger no longer reads as a stuck reading 60 s
later, so a refused write shows one amber row (charger_refused). A frozen
charger still arms and is still caught.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 01:50:44 +01:00
ems-agentandClaude 93c6628eca EV-18 review round 2: the contradiction latch touches only the alarm; an unknown energy reading is not a contradiction
checks / unit (pull_request) Successful in 27m50s
infra-pin / fresh (pull_request) Successful in 2s
- [Critical] The latch set `w = None` before `_car_quarter`, so with cover
  off the guard's input (`car_exclude`) counted the car as house and the
  batteries discharged. The latch now changes only the figure graded for the
  alarm; the car's energy count, the guard's input and the car-over row keep
  the unlatched `car_alarm_w()`. Cover-off N4 twins (energy gap, T9(c) liar,
  SoC 60 % and at the reserve) give the same commands as without the latch.
- [Major] `corroborated()` is False for an unknown energy reading, so one
  missing reading latched a correct figure for the quarter. New
  `CarTracker.contradicted()`: only a meter that answered over a whole window
  and fell short. R1 (energy entity unknown 1 s at E+200, T2 and T3 shapes):
  red for that cycle only, explained from the next.
- Minors: unit checks that a contradiction in our own pause latches nothing
  (MF) and that the latch ends with the quarter (MG).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-19 12:18:06 +01:00
glenn schrooyenandClaude 2cfbc4aec8 EV-15: the add-on's own phase change at the peak reserve raises no false alarm
While the add-on holds the car at 0 A for its own phase change, the car's
figure had no corroboration (not charging), so nothing was explained and the
peak-floor alarm fired once. For grading only, the car's fresh, not stuck
figure now stands in for that sequence (bounded: its own waits plus one
corroboration window), ending at once on Off, Stop, shadow, unplug, another
writer or a refused write. car_exclude, the claim, floor and writes unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 13:26:56 +01:00
Claude 8efc385956 EV-10, EV-11, EV-12: car-alone peak alarm, steady car-over row, own write not another writer
checks / unit (pull_request) Failing after 2m13s
infra-pin / fresh (pull_request) Successful in 2s
EV-10: the car is the cause when the period without it (projected minus the car's
fresh, corroborated average) is at or under the aim, also with the projection
still under it. EV-11: car_over stays on until the test has been false for 180 s.
EV-12: the tracker's own-write mute opens before the write and runs 15 s from its
return.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 15:27:46 +01:00
glenn schrooyenandClaude f31dcb62b6 EV-04 round 3: undo restores the current in shadow mode too, energy rule catches a frozen 6 A figure, settle after a refused select
checks / unit (pull_request) Failing after 21m10s
infra-pin / fresh (pull_request) Successful in 1s
N1 the undo gives the old current back (clamped) in shadow mode; DECISIONS records it as the one write shadow mode allows.
N2 the corroboration looks back to a stretch with at least 40 Wh expected (60 s at 2.4 kW and up, 104 s at 1.38 kW).
L4 the current comes back 10 s after the phase select returned, also when it was refused.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 07:59:15 +01:00
glenn schrooyenandClaude 661a3b009a EV-04 round 2: race-free another-writer check, refused phase select, undo before the select, clamped restore, energy-corroborated car figure
checks / unit (pull_request) Successful in 21m14s
infra-pin / fresh (pull_request) Successful in 1s
M1 the writer ignores a reading taken before its latest confirmed write.
M2 a refused phase select gives the current back and stops after 3 tries (amber row).
M3 Off, shadow mode or a control/safety stop before the select undoes the change.
M4 the restore on shutdown (and the undo) is clamped.
M5 the car's power reaches the alarm path only while the charger's energy meter agrees with it.
L1 fuzz other-writer branch reachable and shown to run. L2 one wording. L3 Batteries-help-off text.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 06:51:15 +01:00
glenn schrooyenandClaude 0c92239a63 EV-04: car Manual mode, never throttled for the peak, no false guard alarms
checks / unit (pull_request) Successful in 21m48s
infra-pin / fresh (pull_request) Successful in 2s
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 05:24:36 +01:00
glenn schrooyenandClaude Opus 5.5 d7b4298092 EV-03 review: one power-unit table for the probe and the reading
checks / unit (pull_request) Successful in 27m3s
infra-pin / fresh (pull_request) Successful in 1s
POWER_UNITS is now derived from _W_PER, so the start-up probe and the
reading cannot drift apart. No behaviour change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-15 16:05:19 +01:00
ev03-devandClaude af7e96e5e5 EV-03 round 4: a power entity that cannot be believed is unreachable
checks / unit (pull_request) Successful in 27m11s
infra-pin / fresh (pull_request) Successful in 2s
- every HA power unit is accepted and converted (mW, W, kW, MW), in the probe
  and in the reading
- a power entity that answers in another unit, with no unit, or not as a
  number makes the reading unavailable: after 30 s it is "Charger not
  reachable" (amber row, WARNING, notification after 5 min), with a Why that
  names the cause (EN and NL)

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 15:06:24 +01:00
ev03-devandClaude 918d44ab33 EV-03 round 3: the power entity is required and reads in W or kW
checks / unit (pull_request) Successful in 27m42s
infra-pin / fresh (pull_request) Successful in 1s
A charger with no usable power entity is refused as "not set up", like a
missing setpoint, read-back or state entity, so House and the house profile
behave as with no charger. An entity that is merely unavailable at probe time
is still the unreachable path. NL: help text "met rust", chip "Laadpaalstoring".

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 13:35:09 +01:00
ev03-devandClaude 678ea13895 EV-03 round 2: a missing car power is unknown, and mode3 E/F has a state
checks / unit (pull_request) Successful in 26m50s
infra-pin / fresh (pull_request) Successful in 2s
- CarTracker.car_w returns None when the current reading carries no power
  (power entity unavailable or in a non-power unit); it can no longer raise
  into the control cycle, /status or the MQTT values.
- mode3 E and F are the card state "fault" (EN and NL).
- chargersim gains fault().

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 12:02:17 +01:00
ev03-devandClaude 984f4335a0 EV-03: the charger reader keeps its own power-unit rule
checks / unit (pull_request) Successful in 27m39s
infra-pin / fresh (pull_request) Successful in 1s
test_pv.py part 6 says only the PV reader's named modules may mention its
material, so chargers.py no longer imports pv.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 10:19:14 +01:00
ev03-devandClaude 89a2eb0b74 EV-03: car charger seam, Alfen HA driver, read-only Car card
checks / unit (pull_request) Failing after 37m42s
infra-pin / fresh (pull_request) Successful in 2s
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 09:52:15 +01:00