car_sun_own now sets spare_w / target_w to None while the step's own meter age
says silent, so no plan start or raise comes from a snapshot value over
meter_max_age_s old; the start comes from a fresh reading after the meter
returns, with its dwell. T44 sweeps a start due just after the silence (red on
68856bc, green now). T24 is labelled N5 and also runs at SoC 50 so the
batteries' setpoints in the silence are compared.
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
The writer step took the meter age from the snapshot of the previous cycle
(silent / unknown_s / hold), so in production order the silent-meter pause
came one cycle late (C21) and a start or raise could still be written at an own
age of 31-39 s (C22, N8). The step now judges its own age: the pause timing and
held_pause, the non-zero write block (nz_block), and the late-readings hold with
its stale rule. Meter values stay from the snapshot; car.held / car.reading and
the arrival sources' spare-unknown check are unchanged.
Also: one DEBUG line per Solar writer step (time, meter age, decision, write);
tools/ev20_sun.drive takes cyc / phase / jitter / cset (default unchanged);
test_ev51.py (T1-T43, N1-N12); DECISIONS states the rule once.
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w