Before the bell ends it replaced today's Home line and the event log with
the kept-for-tonight wording. stand_in() docstring covers the tomorrow case.
Co-Authored-By: Claude <noreply@anthropic.com>
One stale Forecast.Solar tomorrow sensor dropped the whole OPT-17 sum from
17:54 to 20:00. Today readings and the OPT-34 morning rules are unchanged.
Co-Authored-By: Claude <noreply@anthropic.com>
With the forecast sensors silent from 17:05 the kept evening figure ended at
midnight + 3 h, in the middle of the night grid charge, and Leftover solar's
planned level went with it (rig: A 49.8 % against 79.9 %).
- A night grid charge that has started keeps its planned level when the forecast
goes (Controller._latch_charge, store key night_charge_latch), and the narrow
price gap with it (weather_held). A fresh figure still moves the level.
- The evening's tomorrow figure is today's until the bell starts (06:00 local),
up to 15 h old but only if it was usable at midnight (solarfc.Hold.stand_in).
- Screen: "No solar forecast now. The charge under way goes on to its planned
level." (EN/NL) while a latched battery is below its level.
- test_opt34.py (whole nights through the real control cycle, mutants), test_opt27
and test_modes_p4 adjusted to the new window and the kept level.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
F1: the evening rule has an age limit (KEPT_MAX_AGE_S).
F2: the evening bound is the next local midnight (_bounds), right on 25 h and 23 h days.
F5: test that old days are dropped from the stored hold.
Co-Authored-By: Claude <noreply@anthropic.com>
With battery modes off the forecast is still read and shown (Settings,
Simple, and the Forecast tab), but no plan uses it, so "used for tonight's
plan" was not true there (UX-53). "Kept for tonight" is true in every
shape. NL "vanavond" read wrong after midnight; "vannacht" covers the
whole night. DECISIONS' "modes off: nothing reads the sensors" corrected.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Hold.stand_in(): day0 <= now < day0 + 3 h. A tomorrow sensor is asked with
day0 = the next midnight, so the upper bound alone was true all day and a
figure stood in at any hour. test_opt27.py covers daytime tomorrow outages.
Co-Authored-By: Claude <noreply@anthropic.com>
test_modes_p4.py: 'the forecast is lost mid-run' now loses it for good (a hold
that never covers); a second scenario is the same loss with the hold, which
keeps Leftover solar charging. test_opt27.py: a failing check no longer hides
the ones after it.
Co-Authored-By: Claude <noreply@anthropic.com>
Forecast.Solar's sensors stop updating in the evening, so at night every such
site had no forecast: the night cheap run needed 1.5x the cycle cost and
Leftover solar planned nothing. One missed poll also dropped it at once.
solarfc.Hold keeps the last fresh reading of each sensor, for the day it is
for. A missing or stale sensor is covered by it for up to FRESH_S (a short
outage), and from the end of the bell (20:00) until local midnight + 3 h
however old. A tomorrow figure is tomorrow's until midnight and then today's;
a today figure is only today's. Stored in the controller's store
(solar_fc_hold), so an evening restart keeps it. The forecast line says
'Solar forecast read 17:05, used for tonight's plan.' (EN, NL).
test_tariff24_weather.py runs with a hold that never covers: it tests what the
plan does when the forecast IS lost.
Co-Authored-By: Claude <noreply@anthropic.com>