glenn schrooyenandClaude 85542e443b SAFETY-119 round 2: test_safety119 reads through named_absence
checks / unit (pull_request) Successful in 42m22s
infra-pin / fresh (pull_request) Successful in 1s
test_named_absence flagged two unguarded reads (next() without a default,
a list indexed in a check name). Use first(), nth() and present().

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-20 01:38:24 +02:00
glenn schrooyenandClaude e76c70ecb0 SAFETY-119 round 2: one settle window per run of hand-backs
checks / unit (pull_request) Failing after 42m32s
infra-pin / fresh (pull_request) Successful in 2s
A hand-back used to restart the window, so a guard and a charge taking
turns hid the loop's integrator bound for good (0 warnings in 2 h; 28
before the fix). A run of hand-backs (the wire away less than a settle
between them) now hides the bound for at most 11 bound cycles and 22 s in
all, then it counts. The quarter-edge kick stays hidden. No command or text
changes. Tests for the two reviewer mutants that only unit checks caught
(a restart counted as a hand-back; span only), DECISIONS gives the delay at
2 s, 5 s and 60 s. test_safety87.py:543 shortened.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-20 00:52:24 +02:00
glenn schrooyenandClaude b0c2e5977d SAFETY-119: re-pin test_safety84/87 digests (log only); prove it
checks / unit (pull_request) Successful in 41m47s
infra-pin / fresh (pull_request) Successful in 1s
The re-pinned digests differ only in OUTPUT_CLAMP log rows; every command
and claim is the same as without the fix (test_safety119.py part 5).
DECISIONS: the delay at a 5 s meter and the open swap case.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-19 15:30:18 +02:00
glenn schrooyenandClaude c4e15ec4cd SAFETY-119: no "not keeping up" when the loop takes the wire back
When the peak guard or a maintenance charge hands the wire back, the loop's
integrator is re-seeded from that owner's command and kicked by a meter that
does not show it yet. It crossed its rail for a cycle or two and raised
goodwe_integrator_bound while the battery gave what it was told.

The loop's integrator bound is not counted until the plant's settle
(SHORT_CYCLES, SHORT_SPAN_S) has passed since the hand-back. An over-rating
always counts; a bound that lasts warns after the settle. No command
changes and no text changes. test_safety119.py; DECISIONS entry.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-19 14:14:08 +02:00