Commit Graph
14 Commits
Author SHA1 Message Date
ems-agentandClaude 69f58181bc EV-05 round 5: headroom counts only the batteries that can give
checks / unit (pull_request) Successful in 24m24s
infra-pin / fresh (pull_request) Successful in 2s
Review of 8818768: the headroom test compared the output with the site
rating, which still counted a battery refusing to give (SAFETY-73) or under
a safety stop, so the 15 s wait ran at the real maximum (N4). Now only the
units that can give (above their cut-out, not refusing, not stopped,
switched on) count, in what they give and in their ratings.

Tests: R5a (A refuses, B at full rating, against a car-Off twin: the cut at
910, period 3361 W), R5b (headroom and a slow battery: the cut at exactly
15 s), R5c (floor-limited alone decides: cut at once). DOCS wrapped to 79.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 17:27:17 +01:00
ems-agentandClaude 8818768dab EV-05 round 4: the cut waits only while the batteries have headroom
checks / unit (pull_request) Successful in 23m43s
infra-pin / fresh (pull_request) Successful in 1s
Review of d2504ef, brief v5 Expected 8 (owner 2026-11-18): the 15 s wait
needs batteries that can still raise their output: above the cut-out, the
guard neither saturated nor floor-limited, and their output more than 100 W
under what they can give. Otherwise the car is cut at once.

Tests: R4/N4 rows against a car-Off twin (house to 25900 and 25950 W, aim
3400 W) land under the aim; T21/T22 cut at once beyond the batteries; the
T21b catch rows and T44 (0 cut pauses) stay green.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 16:02:01 +01:00
ems-agentandClaude 17a7b299d2 EV-05 round 2: the peak cut waits 15 s while a battery can give
checks / unit (pull_request) Successful in 23m32s
infra-pin / fresh (pull_request) Successful in 1s
Owner 2026-11-18 (dev finding 1, brief v4 Expected 8): while a battery is
above its cut-out, the car's peak cut waits until the guard has wanted power
for 15 s in a row (CUT_WAIT_S), so a cloud edge the batteries catch does not
pause the car. It cuts at once with no battery able, or with 120 s or less of
the 15-minute period left (CUT_NEAR_END_S: waiting 15 s then costs at most
8/7 of the cut, taken off the car at once).

Tests: T21/T22 cut at 15 s and not sooner, the period lands under the aim;
T21b a house step and a cloud edge the batteries catch: no cut, no pause;
T24 (c) late in the period: the cut at once, under the aim; T12's cut row
with the batteries at their cut-out. The harness's battery level model was
1000x too fast (round 1); fixed. The 10-hour day: 0 cut pauses in both
priorities.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 10:13:02 +01:00
ems-agentandClaude 29480fda47 EV-05: car Solar mode (spare sun to the car, Batteries or Car first, cut first for the peak)
checks / unit (pull_request) Failing after 24m58s
infra-pin / fresh (pull_request) Successful in 1s
Solar charges the car from the signed spare sun (car + battery charge - grid
import), less the batteries' room (Batteries first) and the sun kept back,
whole amps rounded down, at most one change per 30 s and only on 1 A. It
starts after ev_start_min of enough sun, holds 6 A for ev_pause_min, then 0 A.
Auto phases through EV-04's safe sequence (4.5 kW / 3 min up, 4.0 kW / 5 min
down, one switch per 10 min). What the peak guard would ask the batteries for
is taken off the car first, at once. Every way out of Solar ends at 0 A,
written once; at shutdown before the inverters go to 0 W.

- app/carmode.py: SolarPlan (pure) and SolarWriter (ManualWriter's one write
  site, its sequence and watch); spare_w, car_target_w, amps_for.
- app/ctl_car.py: Solar inputs, the cut, the solar kWh, EV-15's grace for
  Solar's own 0 A, no "set by the car" for Solar; main.py: shutdown order.
- Home card, HA select.goodwe_car_sun_first, sensor car_today_solar_kwh,
  three options with defaults, strings EN/NL, DOCS, DECISIONS, CHANGELOG.
- test_ev05.py, test_ev05_long.py, tools/ev05_sun.py; test_ev03/ev04 checks
  that pinned "Solar is refused" / "three entities" updated.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 23:54:06 +01:00
glenn schrooyenandClaude Opus 5.5 7788543e09 EV-15 review: reflow the _car_own_pause docstring (one 123-char line)
checks / unit (pull_request) Successful in 22m10s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-17 16:51:41 +01:00
glenn schrooyenandClaude 6d7046fc45 EV-15 round 2: the grace opens when the 0 A write is sent
checks / unit (pull_request) Successful in 20m56s
infra-pin / fresh (pull_request) Successful in 1s
The writer runs beside the cycle and the car can stop before the write
returns, so no sequence existed yet and the latch set. Window now opens at
send (zero_sent_at), cleared on return; ends on another writer in the tail too.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 15:24:30 +01:00
glenn schrooyenandClaude 2cfbc4aec8 EV-15: the add-on's own phase change at the peak reserve raises no false alarm
While the add-on holds the car at 0 A for its own phase change, the car's
figure had no corroboration (not charging), so nothing was explained and the
peak-floor alarm fired once. For grading only, the car's fresh, not stuck
figure now stands in for that sequence (bounded: its own waits plus one
corroboration window), ending at once on Off, Stop, shadow, unplug, another
writer or a refused write. car_exclude, the claim, floor and writes unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 13:26:56 +01:00
glenn schrooyenandClaude b12776c705 EV-10b: grade the alarm on the house alone without the 0 W clip
checks / unit (pull_request) Successful in 22m5s
infra-pin / fresh (pull_request) Successful in 2s
The period without the car was clipped at 0 W, so batteries covering the car
were charged to the house and the floor alarm fired (rig F-1). New
car_exclude_alarm keeps the sign of the rest of the period; car_exclude (the
cover-off guard input) is unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 22:16:29 +01:00
Claude 269b89d6b0 EV-10 round 3: grade the floor case on the same landing with and without the car; per-quarter latches independent of the cover option; stricter write-mute test
checks / unit (pull_request) Successful in 20m56s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 19:28:02 +01:00
Claude 646f61e730 EV-10 round 2: judge the car against the alarm's own landing; test failed writes; honest hold wording
checks / unit (pull_request) Successful in 22m4s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 18:07:25 +01:00
Claude 50d5ae90d2 EV-11: the end of a charging session clears the car-over state at once
checks / unit (pull_request) Failing after 29m5s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 15:41:57 +01:00
Claude 8efc385956 EV-10, EV-11, EV-12: car-alone peak alarm, steady car-over row, own write not another writer
checks / unit (pull_request) Failing after 2m13s
infra-pin / fresh (pull_request) Successful in 2s
EV-10: the car is the cause when the period without it (projected minus the car's
fresh, corroborated average) is at or under the aim, also with the projection
still under it. EV-11: car_over stays on until the test has been false for 180 s.
EV-12: the tracker's own-write mute opens before the write and runs 15 s from its
return.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 15:27:46 +01:00
glenn schrooyenandClaude 661a3b009a EV-04 round 2: race-free another-writer check, refused phase select, undo before the select, clamped restore, energy-corroborated car figure
checks / unit (pull_request) Successful in 21m14s
infra-pin / fresh (pull_request) Successful in 1s
M1 the writer ignores a reading taken before its latest confirmed write.
M2 a refused phase select gives the current back and stops after 3 tries (amber row).
M3 Off, shadow mode or a control/safety stop before the select undoes the change.
M4 the restore on shutdown (and the undo) is clamped.
M5 the car's power reaches the alarm path only while the charger's energy meter agrees with it.
L1 fuzz other-writer branch reachable and shown to run. L2 one wording. L3 Batteries-help-off text.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 06:51:15 +01:00
glenn schrooyenandClaude 0c92239a63 EV-04: car Manual mode, never throttled for the peak, no false guard alarms
checks / unit (pull_request) Successful in 21m48s
infra-pin / fresh (pull_request) Successful in 2s
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 05:24:36 +01:00