Commit Graph
8 Commits
Author SHA1 Message Date
ems-agentandClaude d2504efa82 EV-05 round 3: a refused way-out 0 A is tried again; one cut per excess
checks / unit (pull_request) Successful in 24m5s
infra-pin / fresh (pull_request) Successful in 2s
Review of 17a7b29:
- Critical: every way out of Solar (Off, Stop, shadow, safety stop, charger
  error, stuck reading, no car) now owes a 0 A until the charger takes it:
  tried again 60 s apart, 3 times (EV-04's rule), then the gave-up row and
  CHARGER_REFUSED; never over another writer. Shutdown does not trust last_a
  while a write of ours is unconfirmed. The card no longer says paused while
  the 0 A is not taken.
- Major: an excess episode is taken off the car once, measured from the car's
  power when it began, until the car shows it and 15 s more.

Tests: refused-then-accepted 0 A for each exit, a 0 A never taken, shutdown
during a start write's read-back, a cut from 16 A with a slow car; the fuzz
checks refused exits of every kind (N9).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-18 12:15:00 +01:00
ems-agentandClaude 29480fda47 EV-05: car Solar mode (spare sun to the car, Batteries or Car first, cut first for the peak)
checks / unit (pull_request) Failing after 24m58s
infra-pin / fresh (pull_request) Successful in 1s
Solar charges the car from the signed spare sun (car + battery charge - grid
import), less the batteries' room (Batteries first) and the sun kept back,
whole amps rounded down, at most one change per 30 s and only on 1 A. It
starts after ev_start_min of enough sun, holds 6 A for ev_pause_min, then 0 A.
Auto phases through EV-04's safe sequence (4.5 kW / 3 min up, 4.0 kW / 5 min
down, one switch per 10 min). What the peak guard would ask the batteries for
is taken off the car first, at once. Every way out of Solar ends at 0 A,
written once; at shutdown before the inverters go to 0 W.

- app/carmode.py: SolarPlan (pure) and SolarWriter (ManualWriter's one write
  site, its sequence and watch); spare_w, car_target_w, amps_for.
- app/ctl_car.py: Solar inputs, the cut, the solar kWh, EV-15's grace for
  Solar's own 0 A, no "set by the car" for Solar; main.py: shutdown order.
- Home card, HA select.goodwe_car_sun_first, sensor car_today_solar_kwh,
  three options with defaults, strings EN/NL, DOCS, DECISIONS, CHANGELOG.
- test_ev05.py, test_ev05_long.py, tools/ev05_sun.py; test_ev03/ev04 checks
  that pinned "Solar is refused" / "three entities" updated.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 23:54:06 +01:00
glenn schrooyenandClaude 6d7046fc45 EV-15 round 2: the grace opens when the 0 A write is sent
checks / unit (pull_request) Successful in 20m56s
infra-pin / fresh (pull_request) Successful in 1s
The writer runs beside the cycle and the car can stop before the write
returns, so no sequence existed yet and the latch set. Window now opens at
send (zero_sent_at), cleared on return; ends on another writer in the tail too.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 15:24:30 +01:00
glenn schrooyenandClaude 2cfbc4aec8 EV-15: the add-on's own phase change at the peak reserve raises no false alarm
While the add-on holds the car at 0 A for its own phase change, the car's
figure had no corroboration (not charging), so nothing was explained and the
peak-floor alarm fired once. For grading only, the car's fresh, not stuck
figure now stands in for that sequence (bounded: its own waits plus one
corroboration window), ending at once on Off, Stop, shadow, unplug, another
writer or a refused write. car_exclude, the claim, floor and writes unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 13:26:56 +01:00
Claude 8efc385956 EV-10, EV-11, EV-12: car-alone peak alarm, steady car-over row, own write not another writer
checks / unit (pull_request) Failing after 2m13s
infra-pin / fresh (pull_request) Successful in 2s
EV-10: the car is the cause when the period without it (projected minus the car's
fresh, corroborated average) is at or under the aim, also with the projection
still under it. EV-11: car_over stays on until the test has been false for 180 s.
EV-12: the tracker's own-write mute opens before the write and runs 15 s from its
return.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 15:27:46 +01:00
glenn schrooyenandClaude f31dcb62b6 EV-04 round 3: undo restores the current in shadow mode too, energy rule catches a frozen 6 A figure, settle after a refused select
checks / unit (pull_request) Failing after 21m10s
infra-pin / fresh (pull_request) Successful in 1s
N1 the undo gives the old current back (clamped) in shadow mode; DECISIONS records it as the one write shadow mode allows.
N2 the corroboration looks back to a stretch with at least 40 Wh expected (60 s at 2.4 kW and up, 104 s at 1.38 kW).
L4 the current comes back 10 s after the phase select returned, also when it was refused.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 07:59:15 +01:00
glenn schrooyenandClaude 661a3b009a EV-04 round 2: race-free another-writer check, refused phase select, undo before the select, clamped restore, energy-corroborated car figure
checks / unit (pull_request) Successful in 21m14s
infra-pin / fresh (pull_request) Successful in 1s
M1 the writer ignores a reading taken before its latest confirmed write.
M2 a refused phase select gives the current back and stops after 3 tries (amber row).
M3 Off, shadow mode or a control/safety stop before the select undoes the change.
M4 the restore on shutdown (and the undo) is clamped.
M5 the car's power reaches the alarm path only while the charger's energy meter agrees with it.
L1 fuzz other-writer branch reachable and shown to run. L2 one wording. L3 Batteries-help-off text.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 06:51:15 +01:00
glenn schrooyenandClaude 0c92239a63 EV-04: car Manual mode, never throttled for the peak, no false guard alarms
checks / unit (pull_request) Successful in 21m48s
infra-pin / fresh (pull_request) Successful in 2s
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 05:24:36 +01:00