Commit Graph
9 Commits
Author SHA1 Message Date
Claude dev agent 667b8e9145 UX-13 P5: Dutch text, STYLE check, DOCS screenshots, period editor
checks / unit (pull_request) Successful in 10m45s
infra-pin / fresh (pull_request) Successful in 1s
- app/ui_text/nl.json and app/uitext.py: every page word in Dutch, English
  fallback per key; the page picks by browser language. Home's sentences
  move into ui_text `home_words`, so /status?lang=nl builds them in Dutch.
- test_ui_text.py: EN/NL key and placeholder parity, STYLE limits, jargon
  lists for both languages, no inline details, untranslated Dutch caught.
  Shared rules moved unchanged to tools/style_rules.py.
- tools/ux13_screenshots.sh/.py: DOCS screenshots from the demo fixtures in
  headless Chromium; docs/img/ux13/. Battery modes (P3): no screenshot.
- "Other time windows": a list editor (ui.periods) that builds
  static_profile and names bad times, empty prices, overlaps and gaps.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 16:33:32 +02:00
adminandClaude Opus 5.5 159d7461d8 UX-15: setup-only mode, and the wizard fixes F1, F2, meter, step 1
A new install names no inverter. When that is the startup gate's only
refusal, the add-on now serves the setup wizard in setup-only mode instead
of exiting 78. It builds no controller, MQTT client or meter task, its
HomeAssistant is read-only (every service call refuses before sending),
Controller refuses a read-only HomeAssistant, and /action answers 409.
Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md.

Wizard fixes from the UX-13 P4 test:
- F1: /config/validate converts what it can, so a conversion error blocks
  its own step and the live checks still run; save 422 carries steps.
- F2: saves send the model the page opened (base); only keys this page
  changed are written onto the blob stored now.
- A meter entity missing from Home Assistant is red on the last step.
- Step 1 says the reading went down after a skip that followed a fall.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 08:48:21 +02:00
review-agent 3198f346fd UX-13 P4 review fixes (PR #146, comment 1887)
checks / unit (pull_request) Successful in 10m24s
infra-pin / fresh (pull_request) Successful in 1s
R1: first_start also needs a Store created at this boot (Store.fresh), so
    old never-started sites (both TEST-23 add-ons, one in shadow) stay on Home.
R2: a kettle skip after a fall says on the last step that the reading went down.
R3: the shadow switch goes only on the model the wizard posts, never into V.
R4: Home Assistant not answering is red on the last step.
R5: meter + solar + battery below -300 W flags a reversed battery sensor.
R6: the live checks say what to change and where.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 06:12:09 +02:00
adminandClaude Opus 5.5 be57b87c34 UX-13 P4: the setup wizard for installers
checks / unit (pull_request) Successful in 10m22s
infra-pin / fresh (pull_request) Successful in 1s
The Setup tab draws the Installer view's page model one step at a time,
from each field's `wizard` step in app/uilayout.py: meter (with the kettle
test), inverters and batteries, solar (optional), prices, peak limit
(battery modes: "comes in a later update", OPT-11), check and start.
It reuses P2's controls and saves through /config/validate and
/config/save. No route was added.

- First run: /config/model says `setup_needed` when the stored options name
  no power request entity, or on a new install (no `setup_done` and no
  `auto` in the Store, control not started). The page opens #setup only
  when opened with no route. The wizard's save writes `setup_done`.
- Kettle test: GET ha/entities?entity= reads one entity now, in W. The
  change decides: up keeps meter_invert off, down turns it on; a net or
  import/export meter that goes down blocks the step with what to check.
- Last step: validate.setup_checks() beside the refusals: the meter reads,
  each power request entity exists in HA (bad if not, SAFETY-77), battery
  levels and power with direction, solar sign, prices. Saves with
  shadow_mode on by default, then a confirmed restart naming the 0 W.
- P2 test finding (a): a stale save lists only the keys the other surface
  moved (the blob handed out on open, by fingerprint, against stored now).
- test_setup.py; tools/ux13_wizard_blobs.py makes the 88 blobs the wizard
  can save; all accepted by Supervisor 2026.08.0 AppOptions (offline).
- DECISIONS/UX-13-setup-wizard.md; DOCS "Setup, for a new install".

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-28 05:31:18 +02:00
Claude c9ab48d6fc UX-13 P2: the Installer settings view
- Settings tab: the Installer view (app/static/settings.js), drawn from
  app/uilayout.py through the new app/uipage.py: search, six collapsible
  groups with "n to fix / n to check / n changed" badges and an "applies
  after a restart" chip, radio cards, segmented choices, sliders with units
  (the peak limit in kW), entity pickers with search and the live reading,
  inverter cards, solar rows, locked measured values behind "Change", and
  the add-on's refusals, warnings and info beside the field they name.
- Save path: the page posts its model to the existing config/validate and
  config/save; uimodel turns it into options before the shipped validator,
  so nothing it refuses is saved. No route added. A value equal to the
  stored one is written as stored, so a save that changed nothing writes an
  identical blob. Save bar, then the restart dialog that names 0 W.
- The region choice shows its preset year; Wallonia and Brussels are listed
  as having no preset yet (TARIFF-22). "Classic settings" keeps /config.
- P1 test findings: (a) "Going to 0 W" until the last accepted power request
  is 0 W; (b) the trade blocks and the price line name the feed's own points
  ("Lowest published price"), the hour bars say "hour average"; (c) the entity
  list's WARNING gives a reason on a timeout.
- test_settings.py; test_home, test_haentities, test_uilayout extended.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-28 02:49:58 +02:00
adminandClaude Opus 5.5 fad73d4012 UX-13 P1 review: Home draws only what the cycle would do
checks / unit (pull_request) Successful in 9m36s
infra-pin / fresh (pull_request) Successful in 1s
- Trade blocks: none on a battery with no room, no sale at a negative price
  or while the emptiest battery is at arbitrage's floor, nothing when a
  level is unknown. A give after a charge may use what the charge put in.
- The refusal line names the real reason: prices not published vs gap.
- The plan's peak line uses the guard's ceiling (this month's peak once
  above the cap), as the peak card does.
- House below zero: 0 W inside the idle band, no figure beyond it.
- Price bars are "Low price" / "High price": the add-on trades in one hour.
- Control toggle: one request in flight at a time.
- test_home: the new cases; the house-sign mutation now goes red.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 01:18:33 +02:00
Claude f8d63cc614 UX-13 P1: page shell and Home screen on a structured /status
checks / unit (pull_request) Successful in 9m37s
infra-pin / fresh (pull_request) Successful in 2s
- app/static/{index.html,app.css,app.js}: tabs (Home, Batteries, Settings,
  Setup), hash routes, phone bottom tabs, light/dark. Served inlined at "/";
  the route list is unchanged, and every URL is relative.
- app/homeview.py: /status gains state, now, batteries, plan, attention,
  month_peak and control beside the old fields. The plan is what the add-on
  does today: the arbitrage verdict (the same plan.arbitrage() call as the
  cycle), the monthly cycle, the peak limit, "follows the house".
- The Home plan chart has hover, tap and keyboard-focus tooltips: price bar =
  hour and price; block = what, when, why, kWh and EUR.
- Region preset and year: in config/model (for P2) and on the Home price line.
- test_home.py; test_messages part 8 scans every Home sentence; STYLE plan line.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-28 00:45:01 +02:00
adminandClaude Opus 5.5 badea3cb2d UX-13 P0 review: keep unread keys, back off a failed entity read
checks / unit (pull_request) Successful in 9m30s
infra-pin / fresh (pull_request) Successful in 1s
- uimodel: editing a listed inverter keeps the stored flat keys, and a
  region of "own" keeps a stored price_taxes_profile (both were dropped).
- haentities: a failed read also waits CACHE_S, so polls while Home
  Assistant is down do not queue one 10 s read each.
- ui_text: the Flanders preset names its DSO, and the help says
  Wallonia and Brussels have no figures yet. REGION_PRESETS cites the card.
- tests: decode of a reversed solar row, both kept keys, the backoff.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 23:39:43 +02:00
glenn schrooyenandClaude Opus 5.5 15627c38a6 UX-13 P0: layout table, page<->options derivation, warning tier, entity list
checks / unit (pull_request) Successful in 9m32s
infra-pin / fresh (pull_request) Successful in 1s
The foundation for the new settings page. No visible UI change.

- app/uilayout.py: screen -> group -> part -> field for every option in
  config.yaml (67 fields, 11 derived, 0 hidden), with control, unit, display
  scale, step, entity kind, show conditions, Simple/wizard placement and
  "applies after a restart". Ranges stay in the schema, words in
  translations and the new app/ui_text/en.json.
- app/uimodel.py: options_to_ui()/ui_to_options() for the derived keys (one
  inverter vs the list, solar rows, static_profile from simple prices, a
  year-stamped region preset for the levies figure, and an OPT-11 hook for
  arbitrage_enabled that changes nothing yet). Unchanged derivations write
  the stored values back, so the round trip is exact.
- validate.py: validate.Note, a warn/info tier. Each logged warning is also
  a note when a list is passed; config_notes() adds checks that need live
  data (missing entity, a kW sensor read as W, a limit below this month's
  peak). /config/validate returns them as "notes". No refusal changed: 261
  recorded validator calls, 0 differ (tools/ux13_validator_calls.py).
- GET ha/entities: Home Assistant's entity list for the picker, read through
  hass.states(), cached 30 s, 10 s timeout. When HA is down it answers 200
  with the old list marked old, or an empty list that says why.
- DECISIONS/UX-13-one-layout-table.md amends UX-02's "no option key in UI
  code": keys may appear in uilayout.py and uimodel.py only, both tested.
- Tests: test_uilayout, test_uimodel (round trip over the recorded calls,
  the TEST-23 option files and config.yaml defaults), test_haentities, a
  warning-tier part in test_validate; test_messages scans notes and
  ui_text; test_pv and test_selfconfig part 7 widened on purpose.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 23:11:31 +02:00