R1: first_start also needs a Store created at this boot (Store.fresh), so
old never-started sites (both TEST-23 add-ons, one in shadow) stay on Home.
R2: a kettle skip after a fall says on the last step that the reading went down.
R3: the shadow switch goes only on the model the wizard posts, never into V.
R4: Home Assistant not answering is red on the last step.
R5: meter + solar + battery below -300 W flags a reversed battery sensor.
R6: the live checks say what to change and where.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The Setup tab draws the Installer view's page model one step at a time,
from each field's `wizard` step in app/uilayout.py: meter (with the kettle
test), inverters and batteries, solar (optional), prices, peak limit
(battery modes: "comes in a later update", OPT-11), check and start.
It reuses P2's controls and saves through /config/validate and
/config/save. No route was added.
- First run: /config/model says `setup_needed` when the stored options name
no power request entity, or on a new install (no `setup_done` and no
`auto` in the Store, control not started). The page opens #setup only
when opened with no route. The wizard's save writes `setup_done`.
- Kettle test: GET ha/entities?entity= reads one entity now, in W. The
change decides: up keeps meter_invert off, down turns it on; a net or
import/export meter that goes down blocks the step with what to check.
- Last step: validate.setup_checks() beside the refusals: the meter reads,
each power request entity exists in HA (bad if not, SAFETY-77), battery
levels and power with direction, solar sign, prices. Saves with
shadow_mode on by default, then a confirmed restart naming the 0 W.
- P2 test finding (a): a stale save lists only the keys the other surface
moved (the blob handed out on open, by fingerprint, against stored now).
- test_setup.py; tools/ux13_wizard_blobs.py makes the 88 blobs the wizard
can save; all accepted by Supervisor 2026.08.0 AppOptions (offline).
- DECISIONS/UX-13-setup-wizard.md; DOCS "Setup, for a new install".
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
1. Discard reloads /config/model: after a stale save the page kept the
new fingerprint with the old values, so Discard + Save overwrote the
other surface's change without a 409.
2. Removing cards back to one restores the stored inverter shape, so a
flat site stays flat after add + remove.
3. A choice the page can only keep ("Other time windows") stays offered
while it is the stored value.
4. A load locks every locked value again.
5. at_zero() needs an accepted 0 W write; before the first one Home says
"Going to 0 W" (the heartbeat writes every heartbeat_s, so it clears).
6. A field with a unit drops the translation's "(W)" from its label: the
peak limit read "Peak limit (W)" beside a kW value.
7. A mirrored choice lists the mirrored field's keys, so a search for
static_profile finds the contract on a fixed-price site.
8. test_settings: a save refused by ui_to_options writes nothing.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Settings tab: the Installer view (app/static/settings.js), drawn from
app/uilayout.py through the new app/uipage.py: search, six collapsible
groups with "n to fix / n to check / n changed" badges and an "applies
after a restart" chip, radio cards, segmented choices, sliders with units
(the peak limit in kW), entity pickers with search and the live reading,
inverter cards, solar rows, locked measured values behind "Change", and
the add-on's refusals, warnings and info beside the field they name.
- Save path: the page posts its model to the existing config/validate and
config/save; uimodel turns it into options before the shipped validator,
so nothing it refuses is saved. No route added. A value equal to the
stored one is written as stored, so a save that changed nothing writes an
identical blob. Save bar, then the restart dialog that names 0 W.
- The region choice shows its preset year; Wallonia and Brussels are listed
as having no preset yet (TARIFF-22). "Classic settings" keeps /config.
- P1 test findings: (a) "Going to 0 W" until the last accepted power request
is 0 W; (b) the trade blocks and the price line name the feed's own points
("Lowest published price"), the hour bars say "hour average"; (c) the entity
list's WARNING gives a reason on a timeout.
- test_settings.py; test_home, test_haentities, test_uilayout extended.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p