The stale_live scenario stores a latch ending 2026-11-04 07:15 CET. The first
Controller was built before the datetime patch, so Controller.__init__ judged
that latch against the real clock and it expired on 2026-11-04. Build it after
the patch (clock = scenario start), as the restart path already did. Test-only.
Co-Authored-By: Claude <noreply@anthropic.com>
The run is sized at the batteries' ratings, not the peak limit, so a run too
short to fill a Cheap hours battery is planned again later in the night.
Counting that run alone made B's give grow through the night and A's level
fall after A had bought (round 2: 55 -> 69 -> 41 -> 37 %, A to 56 %).
dayplan._cheap_give_kwh() now also counts the later firm slots before the
expensive hours that a run would still be worth charging in (price + the
spread control asks at most the give run's dearest slot); the Controller
passes the slots and the spread.
test_opt34: back to the original house shapes, fixture and expected values.
B is Off in the nights that test A's level (a Cheap hours B now covers
these hours); B's checks run in new `_b` nights; the 03:00 check runs in a
night from midnight; tail starts A at 60 %; late_fresh reads the kept 6.0.
test_opt36: slot cases, a whole night on one figure (level never moves),
F-1 with B counted (raised level reached and held). test_ux54: the run end
is read from the plan and asserted (02:30); the F1/F2 sweep uses a peak
limit that does not bind and reads a level shown as the target as at it.
Co-Authored-By: Claude <noreply@anthropic.com>
The silent and fresh nights diverged only because the test's fresh sensors
kept reading the evening's 0.4 kWh 'left today' after midnight, while the
kept figure is the 4th's 6.0 kWh (solarfc.Hold.stand_in, as_today): two
different shortfalls (16.5 and 12.7 kWh) that A's ceiling hid until B was
counted. Fresh sensors now read 6.0 after midnight, so fresh and kept are
the same figure; the 0.3 tolerance is back, the other exact values are
recomputed. test_ux54 literals are recomputed too.
Co-Authored-By: Claude <noreply@anthropic.com>
With Cheap hours B counted, A buys only what B cannot reach. The OPT-34
night scenarios use a 1.6 x larger house profile, and the ux54 tab scenarios
a 4.8 kW evening (ux54_scenarios.make(evening=)), so A still charges; the
hard-coded levels become relations.
Co-Authored-By: Claude <noreply@anthropic.com>
After a fresh today reading in the night (02:00 on the rig) went stale
(05:00), Hold.stand_in(as_today=True) served the 17:05 "tomorrow" figure
again until 06:00: the plan went back to 95 %, the latch took it, and
Leftover solar charged back up. read_sum() now skips that stand-in once
every today sensor has given a fresh reading for the day
(Hold.replaced()); the stale newer reading follows the OPT-27 rules.
Co-Authored-By: Claude <noreply@anthropic.com>
- F1: an expired latch is dropped whatever the run state; plan_targets() and the
store loader ignore one that has ended (no stale latch after a restart).
- F2: the "charge goes on" line only while a cheap run is on.
- F3: a battery that is off or no longer Leftover solar leaves the latch.
- F4: a run carries the latch on only if it starts by the bell start (06:00
local) after the latch began (manager's call, 2026-10-31).
Tests: test_opt34 scenarios stale/stale_live and part 5; test_modes_p4 asks at a
moment inside the latch.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
test_opt34.py part 4 drives Controller._latch_charge() directly: a battery
that leaves the plan is dropped at once, does not rejoin while nothing
charges, an empty latch is cleared from the store, and the screen says the
charge goes on only while the latched battery is below its level. Catches
two reviewer mutants that survived the round-2 tests.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
While a forecast is present and the cheap run holds, the night-charge latch is
rebuilt from the plan: a latched battery takes its current level whatever its
role this tick (a fresh figure may lower it below the SoC), one that left the
plan is dropped, a new one comes in only while it charges from the grid.
Test: a fresh brighter figure lowers A below its SoC, the sensors go quiet, A
does not charge back up. CHANGELOG summary says two fixes.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
With the forecast sensors silent from 17:05 the kept evening figure ended at
midnight + 3 h, in the middle of the night grid charge, and Leftover solar's
planned level went with it (rig: A 49.8 % against 79.9 %).
- A night grid charge that has started keeps its planned level when the forecast
goes (Controller._latch_charge, store key night_charge_latch), and the narrow
price gap with it (weather_held). A fresh figure still moves the level.
- The evening's tomorrow figure is today's until the bell starts (06:00 local),
up to 15 h old but only if it was usable at midnight (solarfc.Hold.stand_in).
- Screen: "No solar forecast now. The charge under way goes on to its planned
level." (EN/NL) while a latched battery is below its level.
- test_opt34.py (whole nights through the real control cycle, mutants), test_opt27
and test_modes_p4 adjusted to the new window and the kept level.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC