ems-agentandClaude 7bc8988be0 EV-21: Solar cuts the car first for the quarter peak
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Failing after 1h10m59s
In Solar, when the 15-minute period heads over the aim and the batteries
would have to give more, the car is lowered first: floor((car - excess) /
(230 x phases)) A, 0 under 6 A. At once without real headroom (saturated,
floor-limited, excess beyond what the batteries can add, no battery figure,
cover off, last 120 s), else after at most 15 s. One cut per episode from
its start, deeper only on a growing excess; restart with the start power
under the aim for the start time; none after a 2nd cut in the period.

Grading (formal C2): a Solar car Solar cannot cut is graded, banked and
left in the guard as in Off. A Solar car is never banked. Grey note and Why
"Solar lowered the car for the peak." Manual and Off unchanged.

Tests: test_ev21.py, test_ev21_paths.py, test_ev21_same.py; T49 in
tools/ev20_day.py; T50 in test_ev20_fuzz.py; test_ev20_guard section 8
moved from "as Manual" to "as Off" where Solar cannot cut (T51).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-25 17:01:07 +01:00
Claude d18ed56fad EV-20: T4 through the Controller, T21 (a) on car_cycle itself
checks / unit (pull_request) Successful in 41m4s
infra-pin / fresh (pull_request) Successful in 2s
T4: battery A's power missing, NaN or unavailable, for one cycle (no
write) and for 400 s (no spare, the current held, 0 A at 300 s).
T21 (a): car_cycle on the same projection, guard and reading gives the
same car figure, explains and over in Solar and Manual.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
2026-11-22 20:47:58 +01:00
Claude 226e5a1e8b EV-20: Car Solar mode, spare sun to the car (charging only)
checks / unit (pull_request) Successful in 57m6s
infra-pin / fresh (pull_request) Successful in 3s
Solar as a second writer next to Manual (carmode.SolarPlan, SolarWriter on
ManualWriter's one write site, safe phase sequence and other-writer watch):
signed spare, Batteries first on the batteries' ratings, the margin, whole
amps rounded down, the 30 s / 1 A rule, start and pause dwells, auto phases,
a one-phase car. Every way out ends at 0 A, retried by EV-04's rule; at
shutdown before the inverters, three tries inside 15 s (D3); start-up and a
returning charger or HA write 0 A first (D2); never over another writer's
hold. The peak guard treats a Solar car as a Manual car (D1 wording). Solar
kWh sensor and card line; select.goodwe_car_sun_first; ev_margin_w,
ev_start_min, ev_pause_min with config, validator, translations, DOCS,
DECISIONS and CHANGELOG.

Checks: test_ev20.py, test_ev20_exits.py, test_ev20_writers.py,
test_ev20_guard.py, test_ev20_long.py, test_ev20_long_car.py,
test_ev20_fuzz.py (harness tools/ev20_sun.py, ev20_kit.py, ev20_day.py);
test_ev03/test_ev04 no longer use Solar as the refused example.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w