glenn schrooyenandClaude eb9ccc2730 OPT-36 round 4: count only charge control will make; Solar first drain at the night base
checks / unit (pull_request) Successful in 44m14s
infra-pin / fresh (pull_request) Successful in 2s
Review F1: a slot after B's run counts only if no slot from the expensive
hours on is cheaper (control plans B's charge left in the cheapest window
ahead), and x 0.95 of B's charge is stored. Three-price night: 1ac7fe9 left
the expensive hours 2.61 kWh short; now 0.
Review F2: a Solar first battery's drain until the expensive hours reads each
hour at no less than the night base (the profile is net of the sun). Read net,
a dark morning drained the battery the plan still counted; A's level fell,
the cheap run moved and was lost before it started (+0.40 EUR per 3 days).
The two real-price replays now cost what 0.20.0 does.
F3: the ux54 sweep's peak limit is 15 kW (the option's top). F4: the rest
comes from the grid (EN/NL). F5: CHANGELOG and DECISIONS wording.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-02 12:56:17 +01:00
glenn schrooyenandClaude 05746c0564 OPT-36: Leftover solar counts what Cheap hours and Solar first batteries will give before buying
checks / unit (pull_request) Failing after 59m31s
infra-pin / fresh (pull_request) Successful in 2s
Live 0.20.0: A (Leftover solar, 60 %) charged to 95 % while B (Cheap hours,
94 %) already covered the expensive hours. dayplan.plan() now takes off the
shortfall what Cheap hours batteries will hold when the hours start (the
ceiling or what their cheap run reaches under the peak aim) and what Solar
first batteries will still hold after the night's use. Home reads a give
block after the planned charge, plan_cover() is the plan's own figure, and
the Why line says other batteries cover.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-02 02:03:04 +01:00
glenn schrooyenandClaude Opus 5.5 ae0cd542c0 OPT-23-28 review: the unheld-shortfall line says another battery or the grid
checks / unit (pull_request) Successful in 50m6s
infra-pin / fresh (pull_request) Successful in 1s
With A on Leftover solar and B on Cheap hours (the dynamic scenario, and the
owner's planned setup), the line said "The batteries cannot hold it all. The
grid covers N kWh", while B holds a full charge for the same hours. It now
says "The expensive hours need more than Leftover solar can hold. The rest,
N kWh, comes from another battery or the grid." (NL likewise). DOCS,
DECISIONS and the dayplan/homeview docstrings say the same. Text only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-29 23:21:31 +01:00
glenn schrooyenandClaude 995028bc5d OPT-23, OPT-28: the day plan counts the sun right, and the night charge covers the expensive-hour shortfall
checks / unit (pull_request) Successful in 55m9s
infra-pin / fresh (pull_request) Successful in 1s
OPT-23: a state-only forecast is read from now for every span
(Forecast.between since=), so the plan's per-hour sun adds up to the day's
figure, today and tomorrow. Hourly splits are unchanged. The Forecast tab
reads spans the same way.

OPT-28: a Leftover solar battery buys, from the floor, the sum over the
expensive hours of max(0, house - trust x sun), / EFF. Several Leftover
solar batteries hold it together by capacity, the ceiling passes the rest
on, and what none can hold is said (Plan.uncovered_kwh). Home's grid block,
the Batteries line and the mode help (EN + NL) say the level, what it
covers, and that Leftover solar buys only what the sun will not give.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-29 21:02:18 +01:00