Commit Graph
10 Commits
Author SHA1 Message Date
glenn schrooyenandClaude Opus 5.5 9b1fa758ad OPT-17: the solar forecast can come from several entities, summed
checks / unit (pull_request) Successful in 36m13s
infra-pin / fresh (pull_request) Successful in 1s
New list options pv_forecast_entities and pv_forecast_tomorrow_entities
(same shape as pv_entities); the single-entity keys are unchanged.

- Each member is read in its own unit (Wh/kWh/MWh) in one gather and the
  day is summed. Hourly splits are merged when every member has one, else
  the total goes on the bell.
- A member missing, unavailable, stale, non-energy or bad makes that
  day's forecast unusable (no partial sum). A caution row names it by
  position; the action log names the entity once per change.
- Single key and list both set for one day: refused at start.
- A one-member list behaves exactly like the single key (test_opt17.py);
  the single-key path is byte-identical to e36565f over 24 scenarios.
- Supervisor shape measured: tools/supervisor_shape_probe.py section J.

DECISIONS/OPT-17-several-forecast-entities.md has the rules.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-11 02:55:58 +02:00
Claude eb10537aee OPT-11 P4: solar forecast and day plan
A Home Assistant solar forecast (Forecast.Solar, Solcast or Open-Meteo
shapes) and the add-on's own hourly house use decide, before each cheap
run, whether the sun will fill each battery before the expensive hours.
Leftover solar then buys from the grid only the shortfall; Cheap hours only
skips the part the sun covers; Solar first never grid-charges. No, stale or
failed forecast: P3 option A exactly (12 digests pinned from 5a4cdc2).

Replay (16 recorded days, forecast errors from Elia's day-ahead BE solar):
year-earlier prices P4 19.15 vs P2 19.33 / option A 19.44 / old trade 18.14;
real 2026 prices P4 29.19 vs 32.26 / 32.01 / 31.40 EUR net.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 19:29:32 +02:00
glenn schrooyen 0951cb227f Merge release/1.0 into safety-79-peak-margin
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 11m36s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>

# Conflicts:
#	goodwe_controller/app/uilayout.py
2026-09-28 23:56:33 +02:00
glenn schrooyenandClaude Opus 5.5 7c4c8f5c66 SAFETY-79: peak guard keeps a margin below the limit
checks / unit (pull_request) Failing after 11m34s
infra-pin / fresh (pull_request) Successful in 1s
New option peak_margin_w (default 50 W, 0-500 W). The peak guard, the
forecast checks and the maintenance charge sizing aim at
peak_cap_w - peak_margin_w; the month peak, the bill, headroom, warnings
and every notice keep the real cap. Owner decision 2026-09-28.

peak_margin_w 0 is byte-identical to ed739d4 (tools/safety79_identity.py,
test_peak_margin.py part 1). validate.py rule 12 refuses a value outside
0-500, not whole, or not below the peak limit.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
2026-09-28 23:09:39 +02:00
Claude 2d2b6afb07 UX-13 P3: Simple view and Batteries screen
checks / unit (pull_request) Successful in 11m9s
infra-pin / fresh (pull_request) Successful in 2s
- Batteries: one card per battery with On/Off, the mode list (cheap hours
  and selling greyed out until OPT-11 P3), level, and Now / Today / Why
  lines built in homeview.py. Replaces the OPT-11 P1 minimal cards and uses
  the existing pack_use / pack_mode actions and store keys.
- An Off battery the peak limit still needs says so with its figure; no line
  shows 0 W beside moving power (OPT-11 P1 test F2). Today says "Not planned
  yet" until OPT-11 P3/P4.
- Home's plan leaves Off batteries out, except for the peak limit.
- Settings opens on Simple: the layout's simple fields with an applies chip
  and a note, plus the battery switches and modes. Installer is one tap.
- English and Dutch words in app/ui_text; test_batteries_screen.py; browser
  check tools/ux13_browser_check.py (CHECK=1 ux13_screenshots.sh); new and
  changed screenshots only.

No control, allocator, arbiter or command module changed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
2026-09-28 22:39:43 +02:00
Claude dev agent d69fd8fbfd OPT-11 P1: per-battery mode limits, on/off, solar order
checks / unit (pull_request) Successful in 10m59s
infra-pin / fresh (pull_request) Successful in 1s
A battery's mode is a soft unit limit (source `mode`, P_MODE 35) kept
apart from the hard limits in pre_resolve(). The allocator applies it
only while the site target is decided at or below 35 (new
Resolution.deciding_priority), so the peak floor releases it and a mode
`hi` never meets the site `lo`. At N=1 resolve() applies the same rule
to the site target after stage 2. A mode range without 0 W is dropped
as a software fault, so REFUSE_SIGN stays unreachable from a mode.

compute() gets the loop bound (sum over live units of hard limits with
modes applied), so the loop never asks for watts no battery may give
and the saturation freeze never parks on them. While charging, Leftover
solar weighs 0 so Solar first fills first. Store keys pack_use and
pack_mode per battery, set by two new /action values; Off stops and
skips maintenance with a log line. Minimal Batteries cards (EN/NL).

Off by default (battery_modes_enabled); off, commands are byte-identical
to a5dddad at N=1 and N=2 (test_modes.py part 1).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 18:51:29 +02:00
Claude dev agent 667b8e9145 UX-13 P5: Dutch text, STYLE check, DOCS screenshots, period editor
checks / unit (pull_request) Successful in 10m45s
infra-pin / fresh (pull_request) Successful in 1s
- app/ui_text/nl.json and app/uitext.py: every page word in Dutch, English
  fallback per key; the page picks by browser language. Home's sentences
  move into ui_text `home_words`, so /status?lang=nl builds them in Dutch.
- test_ui_text.py: EN/NL key and placeholder parity, STYLE limits, jargon
  lists for both languages, no inline details, untranslated Dutch caught.
  Shared rules moved unchanged to tools/style_rules.py.
- tools/ux13_screenshots.sh/.py: DOCS screenshots from the demo fixtures in
  headless Chromium; docs/img/ux13/. Battery modes (P3): no screenshot.
- "Other time windows": a list editor (ui.periods) that builds
  static_profile and names bad times, empty prices, overlaps and gaps.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 16:33:32 +02:00
adminandClaude Opus 5.5 be57b87c34 UX-13 P4: the setup wizard for installers
checks / unit (pull_request) Successful in 10m22s
infra-pin / fresh (pull_request) Successful in 1s
The Setup tab draws the Installer view's page model one step at a time,
from each field's `wizard` step in app/uilayout.py: meter (with the kettle
test), inverters and batteries, solar (optional), prices, peak limit
(battery modes: "comes in a later update", OPT-11), check and start.
It reuses P2's controls and saves through /config/validate and
/config/save. No route was added.

- First run: /config/model says `setup_needed` when the stored options name
  no power request entity, or on a new install (no `setup_done` and no
  `auto` in the Store, control not started). The page opens #setup only
  when opened with no route. The wizard's save writes `setup_done`.
- Kettle test: GET ha/entities?entity= reads one entity now, in W. The
  change decides: up keeps meter_invert off, down turns it on; a net or
  import/export meter that goes down blocks the step with what to check.
- Last step: validate.setup_checks() beside the refusals: the meter reads,
  each power request entity exists in HA (bad if not, SAFETY-77), battery
  levels and power with direction, solar sign, prices. Saves with
  shadow_mode on by default, then a confirmed restart naming the 0 W.
- P2 test finding (a): a stale save lists only the keys the other surface
  moved (the blob handed out on open, by fingerprint, against stored now).
- test_setup.py; tools/ux13_wizard_blobs.py makes the 88 blobs the wizard
  can save; all accepted by Supervisor 2026.08.0 AppOptions (offline).
- DECISIONS/UX-13-setup-wizard.md; DOCS "Setup, for a new install".

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-28 05:31:18 +02:00
Claude c9ab48d6fc UX-13 P2: the Installer settings view
- Settings tab: the Installer view (app/static/settings.js), drawn from
  app/uilayout.py through the new app/uipage.py: search, six collapsible
  groups with "n to fix / n to check / n changed" badges and an "applies
  after a restart" chip, radio cards, segmented choices, sliders with units
  (the peak limit in kW), entity pickers with search and the live reading,
  inverter cards, solar rows, locked measured values behind "Change", and
  the add-on's refusals, warnings and info beside the field they name.
- Save path: the page posts its model to the existing config/validate and
  config/save; uimodel turns it into options before the shipped validator,
  so nothing it refuses is saved. No route added. A value equal to the
  stored one is written as stored, so a save that changed nothing writes an
  identical blob. Save bar, then the restart dialog that names 0 W.
- The region choice shows its preset year; Wallonia and Brussels are listed
  as having no preset yet (TARIFF-22). "Classic settings" keeps /config.
- P1 test findings: (a) "Going to 0 W" until the last accepted power request
  is 0 W; (b) the trade blocks and the price line name the feed's own points
  ("Lowest published price"), the hour bars say "hour average"; (c) the entity
  list's WARNING gives a reason on a timeout.
- test_settings.py; test_home, test_haentities, test_uilayout extended.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-28 02:49:58 +02:00
glenn schrooyenandClaude Opus 5.5 15627c38a6 UX-13 P0: layout table, page<->options derivation, warning tier, entity list
checks / unit (pull_request) Successful in 9m32s
infra-pin / fresh (pull_request) Successful in 1s
The foundation for the new settings page. No visible UI change.

- app/uilayout.py: screen -> group -> part -> field for every option in
  config.yaml (67 fields, 11 derived, 0 hidden), with control, unit, display
  scale, step, entity kind, show conditions, Simple/wizard placement and
  "applies after a restart". Ranges stay in the schema, words in
  translations and the new app/ui_text/en.json.
- app/uimodel.py: options_to_ui()/ui_to_options() for the derived keys (one
  inverter vs the list, solar rows, static_profile from simple prices, a
  year-stamped region preset for the levies figure, and an OPT-11 hook for
  arbitrage_enabled that changes nothing yet). Unchanged derivations write
  the stored values back, so the round trip is exact.
- validate.py: validate.Note, a warn/info tier. Each logged warning is also
  a note when a list is passed; config_notes() adds checks that need live
  data (missing entity, a kW sensor read as W, a limit below this month's
  peak). /config/validate returns them as "notes". No refusal changed: 261
  recorded validator calls, 0 differ (tools/ux13_validator_calls.py).
- GET ha/entities: Home Assistant's entity list for the picker, read through
  hass.states(), cached 30 s, 10 s timeout. When HA is down it answers 200
  with the old list marked old, or an empty list that says why.
- DECISIONS/UX-13-one-layout-table.md amends UX-02's "no option key in UI
  code": keys may appear in uilayout.py and uimodel.py only, both tested.
- Tests: test_uilayout, test_uimodel (round trip over the recorded calls,
  the TEST-23 option files and config.yaml defaults), test_haentities, a
  warning-tier part in test_validate; test_messages scans notes and
  ui_text; test_pv and test_selfconfig part 7 widened on purpose.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 23:11:31 +02:00