glenn schrooyenandClaude 0c92239a63 EV-04: car Manual mode, never throttled for the peak, no false guard alarms
checks / unit (pull_request) Successful in 21m48s
infra-pin / fresh (pull_request) Successful in 2s
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 05:24:36 +01:00
ev03-devandClaude af7e96e5e5 EV-03 round 4: a power entity that cannot be believed is unreachable
checks / unit (pull_request) Successful in 27m11s
infra-pin / fresh (pull_request) Successful in 2s
- every HA power unit is accepted and converted (mW, W, kW, MW), in the probe
  and in the reading
- a power entity that answers in another unit, with no unit, or not as a
  number makes the reading unavailable: after 30 s it is "Charger not
  reachable" (amber row, WARNING, notification after 5 min), with a Why that
  names the cause (EN and NL)

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 15:06:24 +01:00
ev03-devandClaude 918d44ab33 EV-03 round 3: the power entity is required and reads in W or kW
checks / unit (pull_request) Successful in 27m42s
infra-pin / fresh (pull_request) Successful in 1s
A charger with no usable power entity is refused as "not set up", like a
missing setpoint, read-back or state entity, so House and the house profile
behave as with no charger. An entity that is merely unavailable at probe time
is still the unreachable path. NL: help text "met rust", chip "Laadpaalstoring".

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 13:35:09 +01:00
ev03-devandClaude 678ea13895 EV-03 round 2: a missing car power is unknown, and mode3 E/F has a state
checks / unit (pull_request) Successful in 26m50s
infra-pin / fresh (pull_request) Successful in 2s
- CarTracker.car_w returns None when the current reading carries no power
  (power entity unavailable or in a non-power unit); it can no longer raise
  into the control cycle, /status or the MQTT values.
- mode3 E and F are the card state "fault" (EN and NL).
- chargersim gains fault().

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 12:02:17 +01:00
ev03-devandClaude 89a2eb0b74 EV-03: car charger seam, Alfen HA driver, read-only Car card
checks / unit (pull_request) Failing after 37m42s
infra-pin / fresh (pull_request) Successful in 2s
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-15 09:52:15 +01:00