Commit Graph
11 Commits
Author SHA1 Message Date
ems-agentandClaude 12c97b56f4 EV-18: no floor alarm at a quarter's start while the car explains the excess
checks / unit (pull_request) Successful in 23m6s
infra-pin / fresh (pull_request) Successful in 2s
EV-15 rig F-A: with both batteries at the peak reserve and the car charging,
PEAK_GUARD_FLOOR_LIMITED and goodwe_peak_soc_floor fired at a quarter's start
and stayed red for the quarter, the excess smaller than the car. Two causes,
both held by the per-quarter latch `_car_need_excl`:
- C2: "without the car" assumed the batteries give 0 W from now on, so what
  the loop still gives below the reserve counted as house (T2 red on base);
- C1: one cycle with no trusted car figure latched it for the quarter (T1).

Owner 2026-11-19 (Q1-Q3): without the car the batteries keep giving what they
give now (lower of two readings, every cycle); a house need seen with a
trusted car figure stays latched to the quarter's end (`_car_need_house`); an
unknown car figure keeps the alarm only while it is unknown. A car known to
draw nothing (fresh reading, not charging) still grades the house's own need.
After a restart or a gap only the rest of the quarter is graded without the
car. A 0 W figure explains nothing outside our own pause (EV-15). The guard's
claim, floor, setpoints and charger writes are unchanged (N4: 41 runs, same
command digests as base).

test_ev18.py: the test plan's T1-T18, T2b, T2c, N2-N5 (tools/ev18_peak.py:
the real Controller across one quarter edge, N=2 at the reserve).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-19 02:59:50 +01:00
glenn schrooyenandClaude Opus 5.5 7788543e09 EV-15 review: reflow the _car_own_pause docstring (one 123-char line)
checks / unit (pull_request) Successful in 22m10s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-17 16:51:41 +01:00
glenn schrooyenandClaude 6d7046fc45 EV-15 round 2: the grace opens when the 0 A write is sent
checks / unit (pull_request) Successful in 20m56s
infra-pin / fresh (pull_request) Successful in 1s
The writer runs beside the cycle and the car can stop before the write
returns, so no sequence existed yet and the latch set. Window now opens at
send (zero_sent_at), cleared on return; ends on another writer in the tail too.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 15:24:30 +01:00
glenn schrooyenandClaude 2cfbc4aec8 EV-15: the add-on's own phase change at the peak reserve raises no false alarm
While the add-on holds the car at 0 A for its own phase change, the car's
figure had no corroboration (not charging), so nothing was explained and the
peak-floor alarm fired once. For grading only, the car's fresh, not stuck
figure now stands in for that sequence (bounded: its own waits plus one
corroboration window), ending at once on Off, Stop, shadow, unplug, another
writer or a refused write. car_exclude, the claim, floor and writes unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-17 13:26:56 +01:00
glenn schrooyenandClaude b12776c705 EV-10b: grade the alarm on the house alone without the 0 W clip
checks / unit (pull_request) Successful in 22m5s
infra-pin / fresh (pull_request) Successful in 2s
The period without the car was clipped at 0 W, so batteries covering the car
were charged to the house and the floor alarm fired (rig F-1). New
car_exclude_alarm keeps the sign of the rest of the period; car_exclude (the
cover-off guard input) is unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 22:16:29 +01:00
Claude 269b89d6b0 EV-10 round 3: grade the floor case on the same landing with and without the car; per-quarter latches independent of the cover option; stricter write-mute test
checks / unit (pull_request) Successful in 20m56s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 19:28:02 +01:00
Claude 646f61e730 EV-10 round 2: judge the car against the alarm's own landing; test failed writes; honest hold wording
checks / unit (pull_request) Successful in 22m4s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 18:07:25 +01:00
Claude 50d5ae90d2 EV-11: the end of a charging session clears the car-over state at once
checks / unit (pull_request) Failing after 29m5s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 15:41:57 +01:00
Claude 8efc385956 EV-10, EV-11, EV-12: car-alone peak alarm, steady car-over row, own write not another writer
checks / unit (pull_request) Failing after 2m13s
infra-pin / fresh (pull_request) Successful in 2s
EV-10: the car is the cause when the period without it (projected minus the car's
fresh, corroborated average) is at or under the aim, also with the projection
still under it. EV-11: car_over stays on until the test has been false for 180 s.
EV-12: the tracker's own-write mute opens before the write and runs 15 s from its
return.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 15:27:46 +01:00
glenn schrooyenandClaude 661a3b009a EV-04 round 2: race-free another-writer check, refused phase select, undo before the select, clamped restore, energy-corroborated car figure
checks / unit (pull_request) Successful in 21m14s
infra-pin / fresh (pull_request) Successful in 1s
M1 the writer ignores a reading taken before its latest confirmed write.
M2 a refused phase select gives the current back and stops after 3 tries (amber row).
M3 Off, shadow mode or a control/safety stop before the select undoes the change.
M4 the restore on shutdown (and the undo) is clamped.
M5 the car's power reaches the alarm path only while the charger's energy meter agrees with it.
L1 fuzz other-writer branch reachable and shown to run. L2 one wording. L3 Batteries-help-off text.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 06:51:15 +01:00
glenn schrooyenandClaude 0c92239a63 EV-04: car Manual mode, never throttled for the peak, no false guard alarms
checks / unit (pull_request) Successful in 21m48s
infra-pin / fresh (pull_request) Successful in 2s
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-16 05:24:36 +01:00