Commit Graph
2 Commits
Author SHA1 Message Date
adminandClaude Opus 5 8a6acd9fa2 SAFETY-56: the gate cannot tell a dead register from a pack that cannot comply, so stop saying it can
checks / unit (pull_request) Successful in 8m0s
Text only. No behaviour change - same conjunction, same limits, same MISSING,
same 0 W, same NOT READY. `tools/safety56_behaviour_trace.py` says so: 2390
capture reads, a 66-cell swept grid, and six driven controller worlds produce
the byte-identical document `6030175e...` on origin/release/1.0 and on this
branch, while the sentences differ.

THE DEFECT. SAFETY-37's conjunction is satisfied by two disjoint worlds - the
register has stopped reporting reality, or the SOURCE cannot comply with the
command - and nothing `freshness.py` is handed separates them. Three sentences
asserted the first. On the live 2026-09-21 episode it was the second: the pack
read 11 % for the whole 850 s hold, every command in that hold was a discharge,
and the register answered the first CHARGE command three seconds later. The
readiness row was worse still, because it asserted a false fact about a NAMED
entity that was present, numeric and updating - so the operator opened
Developer Tools, found it working, and had every reason to conclude the
diagnostics were broken.

THE FIX. Each message states what was OBSERVED and names BOTH explanations.
Three wordings, no shared helper: two are a log line about a behaviour, the
third is a banner about an entity, and a helper serving both would drop
whichever half the other caller does not need. SoC stays STATED, NOT WIRED -
part 11b drives the two worlds at 50 % and 11 % and the sentence does not move
one byte. The row does not branch on `batt_fresh.stale` either: `stale_note()`
already rides `liveness_notes()` a few rows below, so the discriminator is "is
that row there?", and part 11d asserts it is present in one world and absent in
the other.

THE CHECKS. test_freshness.py part 11 builds the pair of worlds with ground
truth written down rather than derived from the published stream, asserts they
are really two (40 of 40 reads differ) while the published stream is
bit-identical, and only then grades the sentences. Eleven mutations, all red:
each of the three sentences reverted (3, 2 and 2 named reds), the two
explanations transposed at ZERO bytes (1), the second explanation deleted (1),
the admission of ambiguity replaced by a ranking (1), all three reverted at
once (5), and two aimed at this card's own check - collapsing the world pair
(2) and emptying the accusation list, which a positive control against the
three sentences as 0.10.1 shipped them catches (1).

AND TWO OF THE ELEVEN FOUND DEFECTS IN THE CHECK RATHER THAN IN THE CODE.
Transposing `label` and `entity` in the row made it unfindable and the run died
on an IndexError - a red with no name and every later check ungraded, FCST-06's
shape exactly; `_s56_row()` returns a named absence now, 0 named reds before, 3
after. And the first invariance run compared a tree with itself, because it
archived a branch whose edits were not committed yet; the tool now REFUSES to
report "behaviour unchanged" unless the sentences halves differ, and both of
its refusals are driven.

SAFETY-57's part 10h check was the handoff and is inverted rather than deleted:
it required the accusation to still be present so that removing it had to be a
deliberate act. This is that act. Its escape clause is untouched.

Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-23 21:02:40 +02:00
adminandClaude Opus 5 43c144b8d9 SAFETY-57: the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested
checks / unit (pull_request) Successful in 7m58s
SAFETY-37's freshness gate reports a battery-power register as MISSING when it
stops following its own command, and a missing input is "command 0 W and keep
commanding" (§11.1 rule 1). The gate's only exit was "an arrival carrying a
DIFFERENT number" - and at 0 W nothing is asking the register to be anywhere.
The state had no exit reachable from inside it, and the log line promised the
opposite in the same sentence that announced the 0 W.

REPRODUCED FROM THE WIRE, NOT MODELLED. scenarios/safety57-2026-09-21/ is 3840
verbatim frames off the RS-485 pair, read from the passive sniffer, decoded by
tools/decode_bus_capture.py (0 unparsed, 0 bad CRC, 0 unknown shapes; the
mode->sign convention is graded off the capture, not trusted). The box was
running 0.10.0, so the 0 W in the trace IS the add-on's own claim:

  10:51:24.7  0x0518 reaches -3 W. Pack at 11 %, the BMS refuses the discharge,
              the inverter idles. THE REGISTER IS HEALTHY AND TRUTHFUL.
  10:51:29.7  the command reaches +1060 W - 800 W of travel
  10:52:00    the conjunction arms. Inverter.batt becomes None
  10:52:21.7  the site commands 0 W, on the wire
  ...         0x0518 does not change value for 850.0 s. The setpoint does not
              change value for 790.0 s. The house exports 2.4 kW throughout
  ~11:04      a human restarts the add-on. That is what ends it

AND IT HAD BEEN ESCAPING BY LUCK. Replaying the committed 16-day loop capture
through the shipped conjunction finds 93 trips whose wait for the BMS
keep-alive pulse that cleared them has a median of 143.4 s, a worst case of
21440.1 s, and 17 of 93 at or beyond this episode's 710 s. That distribution
belongs to the battery's firmware, not to this code.

THE CARD'S OPTION 2 ALREADY HELD AND IS NOT THE BUG. _grade() has required
|standing| >= MOVE_W since SAFETY-37. The trip was at +1060 W and the stuck
state is at 0 W; they are different moments, and an entry-side rule cannot
reach a state entered legitimately and then persisted. Nothing in the
conjunction is weakened here.

THE RULE, SAFETY-13's SHAPE ONE MODULE OVER - which latches get an exit, not
how long the block lasts:

  the verdict is withdrawn when the obligation that produced it has been gone
  for RELEASE_S, and the register is then re-graded from scratch.

RELEASE_S is BATT_OBLIGED_S, 17.0 s - the obligation window already derived in
the file (6.0 plant + 10.0 publish + 1.0 read), taken at the FLOOR of its band
for the mirror of MOVE_W's reason. Which half is safe is the opposite of
SAFETY-13's: being wrong long is the failure being fixed, being wrong short
costs one bounded re-grading window. Below 17 s the release pre-empts the
cheaper exit - the register answering by itself - and that is graded
behaviourally, not asserted.

The whole parked interval is now stale_input_s + RELEASE_S = 32 s. On the live
episode: telemetry back at 10:52:39 instead of 11:05:35, with 0x0518 still
answering the same -3 W. RED BEFORE (release_s=inf, a graded counterfactual and
not a second implementation), GREEN AFTER.

WHAT IT COSTS, AND IT IS NOT SMALL. A register dead for good is re-graded for
ever: over 1201 reads the held number reaches a consumer on 630 (52.5 %)
against 35 (2.9 %) before. Payable only because one window is at most 35 s and
the two consumers hold for 75 s and 85 s, so neither can reach a verdict inside
one and the re-trip clears both windows. No detection SAFETY-37 had is given
back - a permanent None clears the same windows for ever too - and the command
is derived from the P1 meter, never from batt.

Two clocks, deliberately: changed_mono/unchanged_s() stay facts about the
REGISTER, graded_from/graded_s() are the VERDICT's window. Collapsing them
either lies to the operator or defeats the re-grading.

main.py's stale line had its ESCAPE CLAUSE corrected - it promised a clearance
the state could not produce - and gained a STALE WITHDRAWN edge that says in
its own words that nothing has been learned about the register. The DIAGNOSIS
half is SAFETY-56's and is deliberately untouched, with a named check asserting
it is still there so that rewrite has to be deliberate.

Battery: 22 mutations, 21 red, 1 argued equivalent, 0 unexplained survivors.
Two findings kept in DECISIONS: _release()'s move_w test swapped for
unchanged_s SURVIVED at +5 B because every fixture rested at exactly 0 W (habit
11, closed by a 0/100/300 W fixture); and the code shipped a habit-22 comment
claiming the _release/_grade order was load-bearing, which the battery
falsified - the two act on mutually exclusive predicates, so the order is not
observable. MUTATION.md gains habit 23 for a mutation that ran, fingerprinted
clean, and was a no-op on the fixture because `0.0 or x` is x.

Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro, one
file at a time.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-21 12:33:56 +02:00