PRICE-02
11
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
d017fc67bf |
UX-08 phase 2b: short, plain status rows and page banners
Every Commissioning row and every page banner is now worded in app/messages.py (row_*, banner_*): one sentence of at most 15 words, a red row up to three sentences so a latch still says how it clears, banners at most 12 words. No row names a Home Assistant entity: sensors by their setting, solar sources by their place in the list. Reason codes and limits stay on the log line and event list; rows keep the numbers a reader acts on. UX-07 item 1: ClampWatchdog counts over-rating and integrator-bound engagements separately, and after an episode each count shows under its own alarm's title instead of both under "output clamp". No row colour, visibility or banner order changed. Rows carry an "id" so the tests pin meaning rather than wording. The row and banner kinds leave the allowlist (200 -> 168, cap equal). DOCS.md gains "Status page"; choices are in DECISIONS/UX-08-short-notifications.md. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p |
||
|
|
770988c902 |
TEST-26: a missing value in a check is a named FAIL, not a traceback
checks / unit (pull_request) Successful in 8m44s
Checks and prints that indexed an empty list, exhausted next(), or formatted None killed the rest of their file (FCST-06). Read them through the new named_absence.py (nth/first/field/given/present) and conjoin a presence term. - every site in the brief, plus the family the new scan and a sweep found - test_named_absence.py: scans every test_*.py for unguarded filtered-list indexing, next() without a default and numeric formats on maybe-None names; proven to bite; prints what it cannot see, counted - test_price.py 16a: the `_T17_CAPS is _T17_CAPS` tautology now grades the two assemble() calls' arguments - test_control.py: coverage table re-measured on runs graded to the end Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
7b4877d56d |
TEST-15: purge the bytecode cache before a mutation run, not after
checks / unit (pull_request) Successful in 3m35s
FCST-03's developer reverted `self.provisional` to `here.provisional`, re-ran, and reported the mutation as a survivor. It was not one. CPython validates a cached `.pyc` on (source size, source mtime truncated to whole seconds), and that edit moved neither number - same length, same second - so the interpreter loaded the bytecode it already had. Disassembly settled it at the time: the source read `here`, the running code loaded `self`. A mutation run had graded code that was not there, with no error and exit status 0. This does not make the results already on the record wrong. It makes them UNVERIFIED, and that distinction is the whole card - so nothing here re-runs a campaign and nothing here quietly assumes the old numbers hold. REPRODUCED, THEN CLOSED. test_bytecode.py builds a real package whose two return values are the same length, imports it in a real subprocess, rewrites it inside the same second (retrying until both writes land in one whole second - milliseconds, no sleep) and reads back which value ran. Part 1 shows the interpreter running SELF off a file that says HERE. AND THE TWO OBVIOUS MITIGATIONS DO NOT WORK. Measured, not read off documentation: `python3 -B` and PYTHONDONTWRITEBYTECODE=1 are write-side only. Neither stops an EXISTING stale .pyc being read, and a mutation run always has one, because the previous run wrote it. Part 2 grades both still running the old code. The advice in test_control.py's coverage audit led with `-B`; it is corrected here - the purge is the half that works, and `-B` earns its place by keeping THIS run from leaving a cache for the NEXT edit to inherit. NO SLEEP ANYWHERE. One-second mtime resolution is the mechanism, not the enemy. Waiting it out would slow every run down and would still only cover the edit somebody remembered to slow down. THE HARNESS. tools/mutation_run.sh purges, prints a sha256/byte fingerprint of every app/*.py it is about to grade - so a mutation report can say WHICH source produced it, which is the reviewer's addition to this card - runs each suite under `python3 -B`, refuses a tree with no test_*.py (CI-01's rule, for CI-01's reason), and fails if a cache appears during the run. It takes the tree as an argument so the infra repo's replay harnesses can call it without being moved. WHERE IT IS SAID (AC 2). MUTATION.md carries the mechanism, the measurement, the reporting rules and the survey, and every one of the 16 suites now points at it from its docstring. That list is DERIVED FROM THE TREE by test_bytecode.py part 5, so a new suite that joins this directory without the pointer is red - the same failure shape CI-01's file glob exists to prevent. CI WAS ALREADY IMMUNE, AND IS DESCRIBED THAT WAY (AC 4). Verified rather than reasoned: with the checkout bind mounted `-v "$WS:/w:ro"` the interpreter writes no __pycache__ into the tree at all, and it fails SILENTLY - no error, exit status 0 - while the same probe on a writable mount produces one. Each job also rm -rf's its workspace and clones afresh, so nothing crosses between jobs on the shared runner. PYTHONDONTWRITEBYTECODE=1 is added as belt and braces only: the `:ro` is one character wide and the next person debugging a write will be tempted by it. Part 6 grades both ON THE DOCKER COMMAND LINE rather than on the file - the first draft searched the whole workflow and stayed green after the flag was deleted, because the comment explaining it still named it. THE SHIPPED ADD-ON IS NOT AFFECTED and the question is closed: goodwe_controller/Dockerfile has set PYTHONDONTWRITEBYTECODE=1 since it was written. There is no deploy-side finding. THE SURVEY (AC 3), in MUTATION.md, scoped BY THE PROPERTY. The defect is one-directional - a mutation that never took leaves the suite green, so stale bytecode manufactures SURVIVORS and cannot manufacture a red - which puts every "all red, no survivors" claim in the window out of scope, along with mutations executed in-process (SAFETY-07's B1/B2/B3, test_peakguard parts 7 and 10, where no source file is edited) and everything run after the purge discipline landed on 2026-08-31 (SAFETY-24, SAFETY-26, OPT-04, FCST-03's re-run). What is left is the recorded SURVIVORS from source-edit runs before that date. Two were re-run here under the harness and both still stand: TARIFF-01's record_block() ignoring its policy argument, and SAFETY-03's abs() on the clamp limit - 15 suites green each, on the tree as it stood. The rest are labelled still-unverified rather than assumed or re-run; each is one harness run to close, and the moment to spend it is when somebody next touches that module. OUT OF SCOPE AND RECORDED: the infra repo's sim/ replay harnesses import the add-on and write bytecode into both trees (goodwe/sim/__pycache__ exists today), so SAFETY-02's headline replay carries the same exposure. mutation_run.sh takes a tree argument for exactly that, but the change belongs in that repo and some of those harnesses want the rig. RED AND GREEN. Every new check was broken and watched fail: the purge commented out of the harness turns part 4 red (and its non-vacuity probe already proves the fixture would mis-grade without it); one docstring pointer removed turns part 5 red naming the file; `:ro` and the `-e` flag removed from the workflow turn part 6 red. Full suite green, 16 files, in the CI image on a read-only mount - the shape the runner uses. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> |
||
|
|
547d796c5d |
CFG-01 review: widen the rule, refuse the firmware-veto case, fix the stop footgun
Review findings, all confirmed in code before changing anything. THE RULE DID NOT AUTHORISE ITS OWN BEST REFUSAL. The stated test was "makes a safety mechanism inoperative, or makes a stated limit untrue", and a blank setpoint_entity does neither - layer 1 pinning the inverter at 0 W is the failsafe WORKING, as validate.py's own text admitted. The real justification is a second, separate category: the add-on is inert and indistinguishable from healthy. Stated as (a) and (b), with each refusal tagged, and with both halves explicitly bounded - (a) is not "any two numbers that could disagree", (b) is not "anything degraded". Left implicit, the gap is where trivia-creep comes back in. meter_max_age_s ABOVE THE FIRMWARE'S VETO IS NOW REFUSED. The schema allows int(5,300); the firmware's threshold is a compile-time `max_age_s: "30"` and it trips layer 1 at `p1_age_s >= 30`. At 120 the add-on believes a 119 s reading is fresh and keeps commanding while the board has already vetoed and is holding at 0 W - healthy meter, running controller, nothing moving. Structurally identical to the max_w case, and unlike max_w it is settable on this install, so the headline behaviour finally has a live demonstration. That firmware file's own comment says a lower bound on this "belongs in CFG-01, not here". Only ABOVE is refused: below the veto the add-on gives up first, which is fail-safe and visible on its own status page. Scoped to P1 being enabled, because meter_max_age_s governs nothing otherwise. FIRMWARE_INGEST_VETO_S cannot be imported from a compile-time YAML substitution, so it carries a note on the single direction in which it can go stale - and a warning that TEL-06 is editing `ingest_stale`, so a matching integer may stop meaning a matching rule. stop= WAS A LIVE FOOTGUN. It defaulted to None, which made a Controller that cannot stop itself the DEFAULT one. On the late-refusal path that meant: log the banner, return, and leave the process alive forever with no control loop and no exit - the exact "inert but looks healthy" failure this module exists to refuse. Now required and keyword-only, so the broken shape does not construct; test_p1.py's five call sites pass an Event. That whole path had no test and no live demo. It has one now: it drives run_control() against a device that only reports a narrower range once the loop starts, and asserts it refuses, signals, returns, and writes NOTHING - plus the converse, that an agreeing device leads to real writes. This also covers the max_w composition that cannot be reached through the Supervisor on the live install. max_w <= 0 is refused. Schema-blocked in production, but validate_startup_config() is the simulation suite's entry point too, and a non-positive max_w inverts the arbiter's supervised bounds into a contradiction that reads as a safety trip rather than a typo. Verified live 2026-08-28 (backup goodwe_controller-cfg01r2-1787940076): meter_max_age_s 120 refused with a message naming 120, 30, and THE FIRMWARE WINS; no traceback; add-on restored byte-exact and running. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
4d41b0a79e |
TEL-05 review follow-ups: show unchanged_s, name a timeout, keep the poll task alive
Four follow-ups on the reviewed and approved TEL-05 work. Additive; no shipped behaviour changes except the two failure paths below. 1. unchanged_s had no operator surface. DOCS.md told a reader "the transport tracks it as unchanged_s" and there was nowhere to look: main.py built the transport, scheduled run(), and never read the object again. The status page now shows it on the healthy P1 line. Still NOT thresholded and NOT folded into the age - that refusal was reviewed and upheld, because at the converged -10 W this controller aims for a 1 Wh register needs ~6 minutes to move, so any limit false-trips at the target operating point. The whole argument for leaving it to a human requires the human being able to see it. 2. The "equivalent mutant" note on the content_type guard was wrong, and the comment is downgraded to say so. web.Response(text=...) defaults to text/plain, so the fake meter CAN serve valid JSON under the wrong mimetype. Test added; shipped behaviour was already correct. 3. A timed-out poll logged an empty reason: str(asyncio.TimeoutError()) is "", so the status page read "last error:" and then nothing, on a hung meter, at the moment the battery had just gone to 0 W. Falls back to the class name. Note str(err), not `err or ...` - an exception object is always truthy. 4. submit() sat outside the try in poll_once() and run() had no except, so a raise would kill the poll task permanently and SILENTLY - safe (the age climbs, the controller commands 0 W) but indistinguishable from a dead meter. Both wrapped; poll_s is already the retry cadence, so no backoff. Also a comment at the parse_homewizard range(phases) slice: a 3-phase meter configured as 1-phase understates the capacity-tariff figure. Filed separately, not fixed here. 242 checks in test_p1.py (236 before, 6 new). test_control 55, test_arbiter 18, test_maintenance 21, all untouched and green. Each new check proved non-vacuous: six mutations, six named reds, no suite aborts, sources restored byte-identical. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
98109a9b91 |
TEL-05: read the meter, not Home Assistant's opinion of the meter
A fourth meter_source, `homewizard_local`, polling a HomeWizard P1's own local API (GET /api/v1/data) instead of watching an HA entity. The point is the age sensor. sensor.p1_sample_age_s is FW-01's watchdog input, and on every transport we had it measured "time since the value CHANGED", not "time since the meter REPORTED". Home Assistant offers nothing better: a repeated reading emits no state_changed, advances last_reported on neither serialiser, and state_reported cannot be subscribed to at all. Measured twice - 70 s of a frozen meter on the ENV-01 rig, and ten repeated readings against the live house. Our own capture of this house's meter goes 42.2 s and 97.0 s between changes, both past the default meter_max_age_s of 30, so the age sensor would have commanded 0 W on a perfectly healthy meter. Here every HTTP response is an arrival. The meter answered, now, with its current reading; whether the number moved is not consulted. Five identical readings are five arrivals. Reuses TEL-01's pipeline rather than restructuring it: same split_signed sign convention as ha_signed, same make_sample, same ingest stamping, meter_max_age_s, clock-recomputed age, plausibility bounds and the §20 unsigned-decode rejection. A failed or timed-out poll submits nothing, so it is a missing reading - never 0 W - and does not reset the age. meter_poll_s (default 5 s, the meter's own rate) is checked against meter_max_age_s once at startup, like the ha_signed entity ids. ⚠️ An arrival stamp cannot see a FROZEN meter, and no arrival detector can - one answering 200 OK with a stale number is arriving. The local API does expose what HA never had (the total_power_*_kwh registers stop advancing) and the transport tracks it as `unchanged_s`, but it is deliberately not folded into the age and not thresholded: this controller regulates grid toward ~0 W, and at a converged -10 W the export register needs six minutes to move by its 1 Wh resolution while the power figure legitimately repeats. Thresholding that would rebuild the false-trip limit cycle at the exact operating point we aim for. test_p1.py 179 -> 236 checks. Still defaults to off. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
e663e10245 |
TEL-04 review: unshadow the helper, validate config at startup, and record
what the rig proved about the age sensor
Review findings 1, 3, 5 and 6. Finding 2 is deliberately untouched - it is
its own ticket.
3. `built` was rebound at test_p1.py:816 by `built = build_source(...)`,
silently disarming the build() wrapper for anything appended below it.
Renamed to `sel`. Reproduced the reviewer's failure before fixing:
appending a check that calls built() after that line gives
`TypeError: 'HaSignedSource' object is not callable` and aborts at 163 of
180; with the rename the same probe reaches 180 and passes.
5. DOCS.md now states the "length must equal meter_phases" constraint that
config.yaml already carried, plus what leaving the list empty actually
costs: on the surveyed reading the phases carry 2769 W of import while the
connection nets 187 W, so the tariff quantity is understated ~15x.
6. build_source now checks the ha_signed wiring once at startup instead of
once per telegram: a blank p1_net_entity, or a phase list whose length
disagrees with meter_phases, logs an error and disables ingestion. Both
otherwise fail in the single way indistinguishable from a healthy source
nobody has fed yet - no samples, a climbing age, the watchdog holding the
battery at 0 W, and nothing in the log.
1. THE AGE SENSOR. Measured on the ENV-01 rig against the real HomeWizard
integration, meter frozen via hwsim's `?fault=freeze` seam (cleared in a
finally:, rig verified restored):
- websocket state_changed for the meter over 70 s : 0
- last_reported advanced (REST serialiser) : no
- last_reported advanced (websocket serialiser) : no
- subscribe_events(state_reported) : rejected,
"Event filter is required for event state_reported"
So Home Assistant exposes NO arrival signal for a repeated reading, and
the proposed fix - stamp from last_reported via subscribe_entities - is
not available. subscribe_entities listens only to EVENT_STATE_CHANGED, and
as_compressed_state carries no last_reported at all.
The age is therefore "time since the value changed", which on ha_dsmr is
mostly harmless (a telegram moves several entities) and on ha_signed is
not: one entity means a healthy meter under a flat load is
indistinguishable from a dead one. Recorded loudly in DOCS.md, in the
HaSignedSource docstring and in the CHANGELOG, with the measured 42.2 s
and 97.0 s gaps from our own capture.
meter_max_age_s is deliberately NOT widened. The two conditions produce an
identical signal, so a larger number does not separate them - it only
chooses which of the two errors you get, and it would disarm the watchdog
for a genuinely dead meter as well. The honest fix is an arrival stamp the
meter itself provides.
test_p1.py: 174 -> 179 checks, all green. Other three suites unchanged.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
|
||
|
|
632be44f6c |
TEL-04: make a missing build() guard fail legibly instead of aborting
Review point from the non-vacuity run. Deleting build()'s "is the net entity cached at all" guard makes build() raise KeyError rather than return False. That still failed the suite, but by aborting it with a traceback at whichever check ran first - a red that costs the next person ten minutes deciding whether the suite is broken or the code is. New `built()` helper in test_p1.py wraps build() and turns an escaping exception into a returned value, so the comparison against True/False fails by name. Applied only to the ha_signed section; TEL-01's own checks are untouched. Mutation 4 before: 0 named checks red, aborted at check 123 of 174. Mutation 4 after: 2 named checks red - "nothing cached yet builds nothing" and "an unavailable entity does not build a sample" - all 174 reached. Still 174 checks, all green, and the other nine mutations are unchanged. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
8b51a51e20 |
TEL-04: a third meter_source for a single signed entity
TEL-01 shipped ha_dsmr and mqtt_p1, and neither can read the meter that is
actually fitted here. The house has a HomeWizard P1 exposing ONE signed
entity, sensor.p1_meter_active_power (+ import, - export); ha_dsmr wants two
unsigned registers and refuses a negative one outright, which is every
exporting telegram. So sensor.p1_sample_age_s could not be produced at this
site, and FW-01's watchdog needs it - measured, not theoretical: the house P1
went 51.1 s and 36.2 s without a state change overnight, both past
meter_max_age_s 30, so without the age sensor the watchdog would false-trip
the battery to 0 W.
Adds meter_source: ha_signed, reading p1_net_entity (and optionally
p1_phase_net_entities in L1..L3 order for the capacity-tariff peak). The
derivation is split_signed(), sitting next to make_sample's subtraction for
the same reason it does - the moment a user is asked to write two template
sensors that split a signed value, the sign convention is back in unreviewed
YAML underneath a safety input, which is exactly what TEL-01 removed.
The transport is a subclass of HaDsmrSource overriding only _wanted() and
build(), so every rule TEL-01 established is inherited rather than
re-implemented: ingest timestamping, meter_max_age_s, the clock-recomputed
sensor.p1_sample_age_s republished ~1 Hz, the plausibility ceiling, the
"prime the cache from get_states but never build a sample out of it" rule,
"a reconnect emits nothing", and unavailable/unknown treated as a MISSING
reading and never as 0 W.
Defaults to off. An existing install is unaffected until it opts in.
test_p1.py: 122 -> 174 checks. Includes an end-to-end run of the new
transport against a fake Home Assistant websocket, and the sign convention
asserted against real captured readings from
sim/scenarios/ha-p1_meter_active_power-2026-08-{20,23}.json (-5710 W at
13:46 local under full sun is export; +775 W at midnight is import).
Non-vacuity: ten mutations of the new rules, each applied alone and reverted
byte-identical. Nine turn the suite red. The tenth - splitting the per-phase
signed values rather than passing them through - is an equivalent mutant,
because make_sample subtracts the two lists again and does not sign-check
per-phase figures. That is recorded in a ponytail: comment at the site rather
than left for the next reviewer to rediscover.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
|
||
|
|
4bd659c499 |
TEL-01 review fixes: stop the age sensor tripping installs that have no meter
T-1, and it was a fleet-wide trip to zero. publish() emitted p1_age unconditionally, and published_age_s counts from P1Ingest.__init__ when no sample has ever arrived. With meter_source defaulting to off, every existing install would have published sensor.p1_sample_age_s climbing without bound; the ESP32 does `has_state() && state >= max_age_s` and forces the layer-1 failsafe, so each of them would have pinned its inverter at 0 W within 30 s. Exactly the opposite of the zero-regression the off default was for. The key is now omitted from the payload AND from MQTT discovery when P1 is off, so the entity does not exist at all - which is the status quo, and what has_state() is testing for. The predicate is one function, is_enabled(), because the grid reading, the task start and the discovery announcement have to agree or this comes back. T-2, connect no longer manufactures a sample. get_states returns whatever HA currently holds, which after a Core restart is a RestoreEntity value of unknown age; stamping it with ingest_ts=now reset the age and reported a fresh meter that could have been dead for an hour. run()'s own docstring already said a reconnect must emit nothing - the code disagreed with it, and a test asserted the violation. The cache is still primed, so the first real state_changed builds a complete sample; the age just stays honest until one arrives. T-3, gaps are no longer filled with the last held value. The averager held a sample forward across any interval, so a meter dying at 5 kW and returning ten minutes later credited 5 kW x 600 s to the capacity-tariff accumulator - a fabricated peak on a permanent record. The hold is capped at max_age_s: past that the stretch is walked so block boundaries still land correctly, but nothing accumulates and elapsed does not grow, which is what finally makes the comment about a gap dragging the billed average down true. Same threshold for control and billing: a reading too old to steer by is too old to bill by. T-4, the out-of-order/duplicate guard is covered. It was untested, and the reason is worth recording: the obvious assertion passes without the guard, because the negative interval is separately refused by the covered > 0 test. What the guard prevents is the timestamp REWIND, which only shows up one sample later as a re-integrated window. The test now goes one sample later. T-6, DOCS was wrong about latency. meter_max_age_s and stale_input_s stack, so meter death to 0 W is 45 s and not 30. Documented as a table with both clocks. Also documented the T-5 asymmetry rather than papering over it: the age measures arrival, not change, so a stuck MQTT bridge republishing its last telegram still looks fresh. Correct on ha_dsmr, not detectable on mqtt_p1 without a change-detector. Written up as a known limit. Writing the T-1 test caught a second defect in the test itself: it recorded only MQTT topics, and object_id lives in the payload, so "the age sensor is not announced" had been passing for the wrong reason. test_p1.py: 99 -> 122 checks. 14 mutations run, all 14 red, files restored byte-identical - including one per fix above. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
f47f1f0129 |
TEL-01: P1 ingestion, with the derivation and the age the EMS owns
A Belgian P1 meter publishes two UNSIGNED registers, not one signed figure. Until now the add-on asked the installer to bridge that gap with a template sensor, which put the sign convention of the whole control loop in a text box. This moves it into the EMS: net = import - export, derived once, in one place, with a test that fails if anyone inverts it. Two transports behind one contract, chosen by `meter_source`: the HA WebSocket subscribing to the DSMR integration's entities, and MQTT on a configurable topic. Everything downstream reads P1Ingest, so switching is a config edit. `meter_source: off` is the default and keeps the existing meter_entity path, so no installed system changes until it opts in. The other half is the timestamp. Every accepted sample is stamped at ingest with a monotonic clock, `meter_max_age_s` is applied to it, and the age is published as sensor.p1_sample_age_s for the ESP32's stale-input watchdog. That entity is recomputed against the clock every second rather than only when a telegram lands, because HA pushes state only on change: a meter frozen at a constant reading emits nothing and looks, to anything watching the value, exactly like a meter that has died. The age tells them apart. Deliberately absent: any fallback to an inverter-side power figure. The inverter's own AC power correlates 0.998 with battery power and 0.09 with the real meter, so failing over to it means regulating against your own output. A gap stays a gap - a reconnect emits no synthetic sample, and a rejected telegram never resolves to 0 W or refreshes the timestamp. Quarter-hour averages are time-weighted over clock-aligned blocks rather than a mean of samples, so a cadence change cannot bias the capacity-tariff figure, and only offtake is accumulated so a quarter of pure export averages to 0 kW. Per-phase import is kept separately: on an unbalanced three-phase load the phase sum and the connection net are different numbers, and only one of them is billed. test_p1.py: 99 checks, runnable with a bare interpreter and no meter. Includes an end-to-end run of the HA transport against a fake Home Assistant websocket. Stacked on SAFETY-04; nothing here touches control.py. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |