3 Commits
Author SHA1 Message Date
adminandClaude Opus 5.5 29ca9b5157 DOC-1: operator docs name the real P1 entity and a roster that starts
checks / unit (pull_request) Successful in 8m8s
- DOCS.md / config.yaml: the watchdog's P1 age entity is
  sensor.goodwe_p1_sample_age (device "GoodWe" + "P1 sample age", as
  app/mqtt.py announces and the live install recorded), not
  sensor.p1_sample_age_s.
- DOCS.md: the inverters: example and per-entry table carry the required
  bms_soc_floor (and capacity_kwh); config.yaml's schema comment says four
  required keys, not three.
- Field guide: marked v0.1.0/outdated; slew_w row no longer recommends the
  1000 W that SAFETY-39 now refuses. HTML regenerated; the PDF is NOT
  rebuilt (no Chrome here). README/DOCS pointers fixed.
- test_docs.py: the documented roster must pass app/validate.py and the
  schema's per-entry keys; the documented entity id must equal the id
  composed from app/mqtt.py; the wrong id may appear in no shipped doc.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 23:24:50 +02:00
adminandClaude Opus 5 1abca15520 Compatibility gate: check the serial tag, not the model name
Platform is identified by characters 6-8 of the serial number, and only
platform 105 (ES/EM/BP - ESU EMU ESA BPS BPU EMJ IJL) speaks the AA55-era
meter bus this product emulates. The reference unit is 95000BPS225W0290 -> BPS.

Everything with a "-20"/G2 suffix is a different platform: SBP G2 (SPB/SPN) and
ES G2 (ESN/ESC) are platform 745, ET/EH/BT are 205/745/753. PV-only inverters
(SDT/DST/MSU/NSU) have no battery to control at all.

Added as the first item in Step 0 of the field guide, because it is a 60-second
check that decides whether the job can be quoted, and as a table in the README.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016NckgXecasQb2eSsPYNSW6
2026-08-23 01:56:20 +02:00
adminandClaude Opus 5 266684bed7 Field guide as a 10-page A4 PDF, one page per step
Rebuilt the guide as something usable on site rather than a document to read
at a desk: strict order of operations, DO / VERIFY / IF NOT blocks per step,
pass-fail gates in a table, a printable sign-off sheet, and troubleshooting
keyed by symptom rather than by subsystem.

Includes real screenshots of the add-on's own Web UI - captured by running it
against stub data - showing the healthy state and the misconfigured one side
by side, because telling those apart at a glance is the single most useful
skill on site. Plus the ESPHome step from a live builder.

The text lives only in docs/build_guide.py, which renders the HTML and drives
headless Chrome to produce the PDF. One source: a Markdown copy would
inevitably drift from the PDF someone is holding in a cellar.

Pagination is enforced, not hoped for. Each section must render under the A4
printable height (1039 px at 96 dpi) or Chrome silently spills it onto a second
page and the page numbers stop matching the step numbers. Measured every
section rather than eyeballing it: the Web UI reference page was 1170 px and is
now 1017 px, and the PDF comes out at exactly one page per section.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016NckgXecasQb2eSsPYNSW6
2026-08-23 01:44:08 +02:00