Commit Graph
3 Commits
Author SHA1 Message Date
glenn schrooyenandClaude Opus 5 9d593429d3 SEC-2: write down the release path, now that master refuses a direct push
checks / unit (pull_request) Successful in 7m56s
master is the default branch, which is what the Home Assistant Supervisor
clones - so whatever sits on it runs on a real 5 kW inverter. Until today it
had no branch protection at all, while every gate this repo built sat on
release/1.0, the branch that does not ship. 0.10.1 went straight onto master
on 2026-09-22 with no PR, no CI and no reviewer, and it succeeded.

master now carries the same rule as release/1.0 - enable_push false,
required context `checks / unit (pull_request)`, block_admin_merge_override,
required_approvals 0. That is a forge setting and cannot live in a commit, so
the part that can is this: the procedure it implies. Without it the next
release is attempted the old way and fails confusingly at the push.

docs/RELEASE.md records the path (merge to release/1.0, bump version, PR
release/1.0 -> master, wait for green, merge, then `ha store reload` before
the Supervisor offers anything), the before/after protection state of both
branches, and how the gate was proven to bite rather than merely badge green.

Documentation only - no code, no workflow change.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-23 03:43:37 +02:00
adminandClaude Opus 5 1abca15520 Compatibility gate: check the serial tag, not the model name
Platform is identified by characters 6-8 of the serial number, and only
platform 105 (ES/EM/BP - ESU EMU ESA BPS BPU EMJ IJL) speaks the AA55-era
meter bus this product emulates. The reference unit is 95000BPS225W0290 -> BPS.

Everything with a "-20"/G2 suffix is a different platform: SBP G2 (SPB/SPN) and
ES G2 (ESN/ESC) are platform 745, ET/EH/BT are 205/745/753. PV-only inverters
(SDT/DST/MSU/NSU) have no battery to control at all.

Added as the first item in Step 0 of the field guide, because it is a 60-second
check that decides whether the job can be quoted, and as a table in the README.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016NckgXecasQb2eSsPYNSW6
2026-08-23 01:56:20 +02:00
adminandClaude Opus 5 266684bed7 Field guide as a 10-page A4 PDF, one page per step
Rebuilt the guide as something usable on site rather than a document to read
at a desk: strict order of operations, DO / VERIFY / IF NOT blocks per step,
pass-fail gates in a table, a printable sign-off sheet, and troubleshooting
keyed by symptom rather than by subsystem.

Includes real screenshots of the add-on's own Web UI - captured by running it
against stub data - showing the healthy state and the misconfigured one side
by side, because telling those apart at a glance is the single most useful
skill on site. Plus the ESPHome step from a live builder.

The text lives only in docs/build_guide.py, which renders the HTML and drives
headless Chrome to produce the PDF. One source: a Markdown copy would
inevitably drift from the PDF someone is holding in a cellar.

Pagination is enforced, not hoped for. Each section must render under the A4
printable height (1039 px at 96 dpi) or Chrome silently spills it onto a second
page and the page numbers stop matching the step numbers. Measured every
section rather than eyeballing it: the Web UI reference page was 1170 px and is
now 1017 px, and the PDF comes out at exactly one page per section.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016NckgXecasQb2eSsPYNSW6
2026-08-23 01:44:08 +02:00