UX-01: translate the add-on config, and order it by task
checks / unit (pull_request) Successful in 5m1s

The add-on had NO translations/ directory, so Home Assistant fell back to
rendering the raw option KEYS. An operator opening Configuration read
`unit_sign_disagree_w`, `saturation_cycles`, `integrator_max_w` - seventy of
them, in file order, with no description and no way to tell a constant derived
from 1890 closed-loop test runs from their own inverter's rating.

⚠️ PRESENTATION ONLY. Not one default, not one schema range and not one line of
behaviour moved. The 175 non-comment lines of config.yaml are byte-identical to
release/1.0's, reordered; the only comment lines that changed are the group
banners and five sentences whose "above"/"below" the reorder made false.

* translations/en.yaml and translations/nl.yaml: a name and a description for
  all 70 options and all 7 per-entry keys of the `inverters:` repeatable
  section. The Dutch is written for a Flemish homeowner - afname/injectie,
  kwartierpiek, capaciteitstarief - not transliterated from the English.
* ⭐ Every derived constant says WHERE IT CAME FROM and whether to touch it.
  `unit_sign_disagree_s` cites its 1890 closed-loop runs (SAFETY-30);
  `circulation_w` its 924 runs and the measured 400 W knee (SAFETY-31);
  `meter_freeze_s` its 2399 s capture (SAFETY-18); `bms_soc_floor` register
  0x0560. The two numbers that are the operator's - max_w and peak_cap_w - say
  "THIS IS YOUR NUMBER". `cycle_cost_threshold_eur`, which is neither, says it
  is an open product question (OPT-08).
* config.yaml reordered into task order in BOTH halves, comments carried with
  their keys: hardware -> meter -> ratings and limits -> tariff -> maintenance
  -> safety -> advanced.
  ⚠️ test_inverter.py:1788's trap is PRESERVED: the nested per-entry `max_w:`
  still precedes the flat one under `schema:`, and `inverters: []` still ships
  in the `options:` half. Moving the nested block below the flat one is a 1-byte
  edit; it was run and goes red in test_inverter.py and test_translations.py.
* tools/supervisor_shape_probe.py section F MEASURES the result against
  ghcr.io/home-assistant/amd64-hassio-supervisor:2026.08.0 - Supervisor's own
  _read_app_translations(), its own UiOptions, and the frontend's label
  resolution transcribed from the shipped bundle - and prints every rendered row
  in both languages. `all cases passed`, exit 0.
* ⚠️ ONE MEASURED NEGATIVE RESULT, NOT GLOSSED: the per-entry keys inside the
  `inverters:` section still render RAW on frontend 20250925.1, because a
  list-of-objects goes to ha-selector-object and the converter sets no `label`
  and no `translation_key`. The `fields:` translations are shipped and validated
  - that is Supervisor's own shape for this - but this card does not claim they
  reach the screen. The `inverters` label and description do.
* test_translations.py: a translation naming a non-existent option, or an option
  with no translation, fails CI - both directions, both languages, top level and
  per entry. Mutation-tested BOTH WAYS: eleven in-process mutations each
  required to NAME the key they broke, plus a negative control; six more run on
  disk through the purge-and-re-read protocol. Two of the eleven are the ones
  that cost the WHOLE FILE rather than one label - an unrecognised top-level
  block, and a `network:` value that is not a string. Supervisor drops a file
  that fails SCHEMA_APP_TRANSLATIONS with only a log warning, so those silently
  return the entire tab to raw keys; neither is reachable through the
  `configuration:` coverage, which is why they were hunted for and closed.
* tools/translations_lint.py is the hand parser CI needs (no PyYAML in the
  add-on image) and the probe grades it, key by key and string by string,
  against Supervisor's own loader. It is strict and RAISES rather than skipping;
  nine malformed shapes prove it.

Full 20-file suite green (19 existing + test_translations.py).

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
Claude Opus 5
2026-09-05 12:02:56 +02:00
parent 3993f9f32b
commit fef6ef20a4
8 changed files with 1772 additions and 315 deletions
+275
View File
@@ -0,0 +1,275 @@
# Home Assistant add-on translations - ENGLISH (UX-01)
#
# ⚠️ WHAT THIS FILE IS FOR, AND WHAT HOME ASSISTANT ACTUALLY DOES WITH IT.
# Without a `translations/` directory the Configuration tab renders the raw
# option KEYS - `unit_sign_disagree_w`, `saturation_cycles`, `integrator_max_w`.
# The frontend keeps a field when `e.name in options || e.required`, and all 70
# keys are in `options:` (59 of them are `required` as well), so ALL SEVENTY are
# rendered, always, in `schema:` order, with no description. This file is what
# turns that into sentences.
#
# HOW IT IS READ, measured on the Supervisor image this site runs
# (ghcr.io/home-assistant/amd64-hassio-supervisor:2026.08.0):
#
# * `supervisor/store/data.py:_read_app_translations()` reads every
# `.yaml`/`.yml`/`.json` in this directory, keyed by FILE STEM (so this file
# is the `en` translation), and validates each through
# `SCHEMA_APP_TRANSLATIONS`: `configuration: {str: {name (required),
# description, fields}}` plus `network: {str: str}`. ⚠️ A FILE THAT FAILS
# THAT SCHEMA IS DROPPED WITH A LOG WARNING AND NOTHING ELSE - the add-on
# goes on rendering raw keys and nobody is told twice. tools/
# supervisor_shape_probe.py section F is what says it loaded.
# * The frontend resolves each label as
# `translations[<user's language>]?...name || translations["en"]?...name ||
# schema.name`, and the helper text the same way with `description`. ⚠️ THE
# FALLBACK IS PER KEY, so a key missing from nl.yaml degrades to this file,
# while a key present but wrong does not degrade at all.
#
# ⚠️ ORDER IS NOT SET HERE. `App.schema_ui` is `UiOptions(...)(data["schema"])`,
# so the Configuration tab renders in the order of config.yaml's `schema:`
# block. The order below only mirrors it so the two files read alike.
#
# ⚠️ ADD-ON OPTIONS ARE A FLAT LIST. There is no section-header primitive, no
# per-option "advanced" flag, no units on the input and no sliders, so grouping
# is approximated by ORDER plus the `Group · ` prefix in each label. Do not
# promise the operator visual sections; there are none.
#
# ⚠️ EVERY DERIVED CONSTANT SAYS WHERE IT CAME FROM. The Configuration tab
# presents a number read off 1890 closed-loop test runs and the operator's own
# inverter rating as the same kind of field. The descriptions are the only place
# that difference can be stated, so a derived value names its campaign and says
# "do not change without re-deriving", and a value that is genuinely the
# operator's says so too.
configuration:
setpoint_entity:
name: "Hardware · Inverter setpoint entity"
description: "The ESPHome number entity this add-on writes the power setpoint to, normally number.*_goodwe_setpoint_w. This is the only thing the add-on commands. Leave it empty if you fill in the inverter list below: a site with a roster must not also name one loose actuator, and the add-on refuses to start when both are set."
soc_entity:
name: "Hardware · Battery charge level entity (%)"
description: "The sensor that reports the pack's state of charge in percent. Use the ESP32's own reading, not a figure computed somewhere else. The maintenance cycle and every charge-level floor read this."
batt_entity:
name: "Hardware · Battery power entity (W)"
description: "The sensor that reports this inverter's own battery power, positive while discharging. On this installation that is holding register 0x0518, read by the ESP32. The sign watchdog and the circulating-power alarm both grade the inverter against this reading."
batt_invert:
name: "Hardware · Battery power sign is reversed"
description: "Only switch this on if your battery power sensor reports discharging as a negative number. The add-on expects positive to mean discharging."
inverters:
name: "Hardware · Inverter list (leave empty if you have one inverter)"
description: "Leave this empty unless the site really has more than one inverter. EMPTY DOES NOT MEAN 'not configured yet': it means the four entity settings above, together with the inverter rating and the battery cut-out under Limits, describe the one inverter you have. That is what every existing installation reads, and nobody has to touch anything. Filling this in REPLACES those settings instead of extending them, and nothing is inherited: each entry has to name its own actuator, its own rating and its own battery cut-out, so that no inverter is ever judged against another unit's numbers. The flat setpoint entity above must then be left empty."
fields:
name:
name: "Name"
description: "A short identifier for this inverter, for example inverter-a. It gives this unit its own namespace for its safety latch, heartbeat and write bookkeeping in the add-on's state file, so two units may not share one."
setpoint_entity:
name: "Setpoint entity"
description: "This inverter's own ESPHome number.*_goodwe_setpoint_w. Two entries may not name the same one - two writers on one actuator is refused at startup."
max_w:
name: "Inverter rating (W)"
description: "The supervised ceiling on what may be written to THIS inverter; the site's ceiling is the sum over the list. Required of every entry: an entry without one would have to borrow a rating, and judging one inverter against another unit's numbers is exactly the fault this per-entry list exists to remove."
bms_soc_floor:
name: "Battery cut-out level (%)"
description: "The percent at which THIS pack's own battery management system cuts out. Read it off the pack that is actually installed (register 0x0560) before that pack is ever commanded; do not copy another unit's figure. Required of every entry, deliberately: an optional one would be a defaulted one, and one default for two batteries of different models protects the shallower pack with the deeper pack's number."
soc_entity:
name: "Battery charge level entity (%) (optional)"
description: "This pack's own state of charge. Leave it empty if this unit reports none - that is what it means, and it never falls back to another unit's sensor."
batt_entity:
name: "Battery power entity (W) (optional)"
description: "This unit's own battery power, positive while discharging. Leave it empty if this unit reports none; nothing is inherited from another entry."
batt_invert:
name: "Battery power sign is reversed (optional)"
description: "Only for this entry: switch it on if this unit's battery power sensor reports discharging as a negative number."
estop_fitted:
name: "Hardware · RS485 emergency stop is fitted"
description: "Whether the RS485 emergency stop is physically installed. It only drives the warning banner on the status page; it changes no control behaviour."
meter_source:
name: "Meter · Where the meter reading comes from"
description: "'off' keeps the single Home Assistant entity below, which is what an existing installation runs on until you choose otherwise. ha_dsmr subscribes to the DSMR integration; mqtt_p1 reads an MQTT topic; ha_signed reads one signed entity, which is what a HomeWizard P1 publishes; homewizard_local polls the meter's own local API and skips Home Assistant entirely. ⚠️ Only homewizard_local can tell 'the meter has not answered' apart from 'the value has not changed', so it is the only source on which the frozen-meter alarm means anything."
meter_entity:
name: "Meter · Grid power entity (W)"
description: "The net grid power sensor, used when the meter source is 'off'. POSITIVE MUST MEAN DRAWING FROM THE GRID. Get this the wrong way round and the loop drives the battery in the wrong direction; use the sign switch below rather than a template sensor."
meter_invert:
name: "Meter · Grid power sign is reversed"
description: "Switch this on if your grid sensor reports drawing from the grid as a negative number."
meter_phases:
name: "Meter · Number of phases (1 or 3)"
description: "Must match your connection. A telegram whose phase count disagrees is rejected as it arrives and logged, so a wrong value shows up straight away as 'no telegrams accepted' rather than as a quietly wrong number. The range accepts 2, but that is not a real Belgian connection."
p1_host:
name: "Meter · HomeWizard P1 address"
description: "For meter source homewizard_local only: the meter's own address on your network, as host or host:port, for example 192.168.2.250."
meter_poll_s:
name: "Meter · Seconds between meter polls"
description: "For meter source homewizard_local only. 5 s is the meter's own update rate, so there is nothing to gain below it. It must stay well under the staleness limit below - the reading is never fresher than this interval - and the add-on refuses to start if it is at or above that limit."
meter_max_age_s:
name: "Meter · A reading counts as stale after (s)"
description: "Beyond this the grid figure counts as missing. On its own it does not command 0 W: the 'inputs missing' timer under Advanced starts only after this one has expired, and the two stack. 30 s is six polls of headroom at the default poll interval."
meter_mqtt_topic:
name: "Meter · MQTT topic"
description: "For meter source mqtt_p1 only: the topic the P1 readings are published on."
p1_import_entity:
name: "Meter · Import register entity (W)"
description: "The UNSIGNED consumption register. Do not point this at a signed template sensor: the add-on works out net power itself as import minus export, so the sign convention lives in tested code rather than in unreviewed YAML."
p1_export_entity:
name: "Meter · Export register entity (W)"
description: "The UNSIGNED injection register, the counterpart of the import register above. Same rule: no signed template sensor."
p1_net_entity:
name: "Meter · Signed net power entity (W)"
description: "For meter source ha_signed only. ONE signed sensor: positive is drawn from the grid, negative is fed back into it. Do not split it into two template sensors - the add-on does that split itself, so that it is tested."
p1_phase_import_entities:
name: "Meter · Per-phase import entities (L1, L2, L3)"
description: "Optional, in L1..L3 order. Needed for the capacity-tariff quarter-hour peak on a three-phase connection. The number of entries must equal the number of phases above."
p1_phase_export_entities:
name: "Meter · Per-phase export entities (L1, L2, L3)"
description: "Optional, in L1..L3 order, alongside the per-phase import entities above. The number of entries must equal the number of phases."
p1_phase_net_entities:
name: "Meter · Per-phase signed net entities (L1, L2, L3)"
description: "For meter source ha_signed only. Optional, in L1..L3 order, each signed the same way as the net entity above. Same job as the per-phase import and export entities: the capacity-tariff quarter-hour peak on a three-phase connection. The number of entries must equal the number of phases."
max_w:
name: "Limits · Inverter rating (W)"
description: "THIS IS YOUR NUMBER, not a derived one: the hard ceiling on what may ever be commanded, in watts. Set it to what your inverter is actually rated for, start low and raise it once the site has been commissioned. It is not read at all when the inverter list is filled in - each entry then carries its own, and the site ceiling is their sum. Several safety thresholds must stay below it, and the add-on refuses to start if one does not."
bms_soc_floor:
name: "Limits · Battery cut-out level (%)"
description: "MEASURED, not chosen: the percent at which the pack's OWN battery management system stops discharging, whatever this add-on is set to. Register 0x0560 reads 10 on the reference GW5000S-BP. Read it off the pack you actually have rather than copying this figure. It is here so the add-on can refuse a capacity-guard floor at or below it: such a floor could never bind, the BMS would win first, and the status page would report an energy backstop that does not exist. Not read when the inverter list is filled in - each entry then states its own pack's cut-out."
peak_cap_w:
name: "Limits · Capacity-tariff target (W)"
description: "THIS IS YOUR NUMBER: the quarter-hour average demand the peak guard tries to stay under. Take it from your grid contract - in Belgium it is the capacity-tariff peak your distribution charge is billed on."
peak_forecast_entity:
name: "Limits · Quarter-hour demand forecast entity (W)"
description: "Optional. A forecast of the current billing quarter's average demand. Leave it empty and there is no capacity cap at all."
peak_soc_floor:
name: "Limits · Peak guard will not discharge below (%)"
description: "DERIVED, not picked (SAFETY-24): the reference pack holds 13.8 kWh usable and the worst modelled peak-shaving day asks for 878 Wh, which is 6.4 %, so 20 % sits ten points above the pack's own cut-out and still leaves the guard about 1.6 of its worst observed days of room. ⚠️ IT BOUNDS THE PEAK GUARD ONLY. It is not a reserve for the whole pack: ordinary self-consumption discharges straight past it and goes on down to the battery cut-out, and raising this number does not change that by a tenth of a percent. It must stay strictly above the battery cut-out or the add-on refuses to start. Do not change it without re-deriving it."
price_provider:
name: "Tariff · Dynamic price source"
description: "Where day-ahead or real-time prices come from. 'off' is what ships, and means this site runs on the static tariff below with no trading. ⚠️ Switching it on today fetches, checks and publishes prices and changes no energy decision - nothing consumes the price series yet. It may not be combined with the two legacy Home Assistant price entities further down: two price sources on one site, one of which silently wins, is refused at startup rather than left looking armed."
price_markup_eur_kwh:
name: "Tariff · Supplier markup (EUR/kWh)"
description: "Your supplier's margin. The add-on adds it ONLY when the chosen price source does not already include it - under engie_dynamic, totalenergies_dynamic, eneco_eddy and manual_csv it is ignored, and logged as ignored, never applied twice."
price_taxes_eur_kwh:
name: "Tariff · Levies and VAT (EUR/kWh)"
description: "Taxes and levies per kWh, added under the same rule as the supplier markup: only when the chosen price source does not already carry them."
export_price_eur_kwh:
name: "Tariff · Injection price (EUR/kWh)"
description: "What you are paid for feeding a kWh back into the grid, all in. One number rather than a series: no supplier here publishes a dynamic injection curve. In Belgium it is often close to zero, which on its own strongly favours using your own production over exporting it. It may be negative - at midday in summer you can be paying to export."
static_profile:
name: "Tariff · Fixed or day/night tariff (one line of JSON)"
description: "Your fixed or day/night contract, written as a single line of JSON. RECOMMENDED EVEN ON A DYNAMIC CONTRACT: this is what the add-on falls back to when the price feed dies, and with it empty a dead feed leaves the site with no tariff at all. The periods must cover every day type exactly once, with no gap and no overlap - a gap is refused at startup rather than filled in, because an invented price is one a strategy would trade on. A fully fixed tariff is one period covering 00:00-24:00 on all days. Prices are ALL IN; the markup and levies above are not added to them. Note that a window written 22:00-07:00 for mon-fri does NOT cover Saturday morning, so a weekend row is required rather than decorative."
price_csv_path:
name: "Tariff · Price CSV file"
description: "For price source manual_csv only: where in /share the add-on reads your own price file from."
price_feed_url:
name: "Tariff · Price feed URL override"
description: "Leave empty to use the chosen source's own feed. Only a host that source itself declares is accepted, so this cannot be pointed anywhere."
price_horizon_h:
name: "Tariff · How far ahead to fetch prices (hours)"
description: "How many hours of prices to ask the source for."
price_timeout_s:
name: "Tariff · Price request timeout (s)"
description: "How long a single request to the price source may take before it is given up on."
price_now_entity:
name: "Tariff · Current price entity (older price path)"
description: "The older way of getting a price, kept because retiring it would take the maintenance cycle's only price signal away from a live installation. The add-on reads this and the average below and derives exactly one thing from them - whether now is cheaper than average - which only the maintenance cycle's cheap-window charging uses. It may not be combined with a dynamic price source."
price_avg_entity:
name: "Tariff · Average price entity (older price path)"
description: "The average the current price is compared against. Only meaningful together with the current-price entity above, and like it, may not be combined with a dynamic price source."
arbitrage_enabled:
name: "Tariff · Trade on the price spread"
description: "Charge in the cheapest published hour and discharge in the dearest, but only when the spread covers what the round trip costs. OFF in the shipped configuration, deliberately: this is the first strategy in the add-on that moves energy against the meter on purpose, so it is armed on purpose or not at all. It needs both a price source and a P1 meter, and the add-on refuses the combinations that cannot work rather than letting them look armed."
cycle_cost_threshold_eur:
name: "Tariff · Cost of one full charge/discharge cycle (EUR/kWh)"
description: "What one full round trip costs per kWh: wear on the pack plus conversion losses. A price spread smaller than this loses money and battery life, so it is not traded. ⚠️ THIS ONE IS NOT DERIVED FROM A MEASUREMENT. 0.10 is a product decision and it is still an open question with the owner (OPT-08). At this value a fixed day/night site does not trade at all - the realistic Belgian day/night spread is about 0.08 EUR/kWh - and that is the correct verdict at this number, not a fault."
arbitrage_soc_floor:
name: "Tariff · Trading may not discharge below (%)"
description: "The reserve price trading may not spend. Deliberately not the same key as the maintenance floor: pointing a trading strategy at the monthly balancing cycle's numbers would couple two unrelated policies through one setting."
arbitrage_soc_ceiling:
name: "Tariff · Trading may not charge above (%)"
description: "The headroom price trading may not fill. The counterpart of the trading floor above, and kept separate from the maintenance target for the same reason."
maintenance_enabled:
name: "Maintenance · Run the monthly battery cycle"
description: "A deliberate deep discharge followed by a full recharge and a hold, so the battery management system can recalibrate its charge estimate and balance the cells. Off by default."
maintenance_interval_days:
name: "Maintenance · Minimum days between cycles"
description: "The shortest gap between two maintenance cycles."
maintenance_start_hour:
name: "Maintenance · Hour of day a due cycle starts"
description: "Local hour, 0 to 23, at which a cycle that has become due begins."
maintenance_discharge_w:
name: "Maintenance · Discharge rate (W)"
description: "How fast the cycle drains the pack; the surplus is exported. Above the inverter rating it is CLAMPED to the rating rather than refused - the cycle still completes, just more slowly, and the status page says so. It ships at 2000 to match the shipped rating; raise the rating first, then this."
maintenance_charge_w:
name: "Maintenance · Recharge rate (W)"
description: "⚠️ MUST STAY AT OR BELOW the inverter rating, and the add-on refuses to start otherwise. Above it, the cheap-window charge shaping asks for more than the supervised limit allows, the arbiter resolves that contradiction to 0 W, and maintenance would silently never charge in a cheap window on a default installation. It is also capped again by whatever headroom the peak guard leaves."
maintenance_soc_floor:
name: "Maintenance · Discharge down to (%)"
description: "The depth the monthly recalibration deliberately goes to, once a month, on purpose. ⚠️ THIS IS NOT THE PEAK GUARD'S FLOOR: that one is the depth a money-saving discharge may never reach on any day. The right values genuinely differ - 11 here against 20 there - which is why they are two separate settings and must not be merged."
maintenance_soc_target:
name: "Maintenance · Recharge up to (%)"
description: "The level the recharge phase aims for before the hold begins."
maintenance_hold_min:
name: "Maintenance · Hold at full for (minutes)"
description: "How long to sit at the target so the battery management system can finish balancing the cells."
sign_disagree_w:
name: "Safety · Sign watchdog threshold (W) — measured, do not change"
description: "MEASURED, NOT CHOSEN (SAFETY-02). Both the setpoint being emitted and the grid reading must exceed this before their opposite signs count as a disagreement at all. On the captured healthy day (2026-08-23) sign agreement over the gated samples is 93.4 %; on the captured fault day (2026-08-20) the clusters run 0.0-10.5 % with opposed runs up to 1752 s. There is no reason to move this without a new capture that says so. It must stay below the inverter rating or the watchdog can never fire, and the add-on refuses that configuration."
sign_disagree_s:
name: "Safety · Sign watchdog hold (s) — measured, do not change"
description: "MEASURED, NOT CHOSEN (SAFETY-02). How long the setpoint and the meter must stay opposed, continuously, before the add-on commands 0 W and latches until an operator starts control again. 180 s sits in the middle of a very wide measured gap: the longest legitimate opposed run on the healthy day is 30 s, while the fault day still trips 13 times at 300 s. Do not change it without a new capture."
unit_sign_disagree_w:
name: "Safety · Per-inverter sign threshold (W) — derived, do not change"
description: "TWO OR MORE INVERTERS ONLY; with one inverter this setting does nothing at all. DERIVED FROM 1890 CLOSED-LOOP TEST RUNS on the two-master rig (SAFETY-30), in which nothing was faulty, swept across the whole range this add-on accepts for loop gain and slew rate. 250 W is exactly half the saturation threshold, so the smallest divergence this can see is precisely the gap at which the control law itself already says the inverter is not following. Do not change it without re-deriving it. It must stay below the inverter rating or it can never fire."
unit_sign_disagree_s:
name: "Safety · Per-inverter sign hold (s) — derived, do not change"
description: "TWO OR MORE INVERTERS ONLY. DERIVED FROM 1890 CLOSED-LOOP TEST RUNS (SAFETY-30): 85 s is 8.5 times the worst legitimate opposition those runs produce (10.0 s), 2.8 times the firmware's own 30 s link veto, and under half the 180 s the site-wide check takes. Do not change it without re-deriving it."
site_sign_disagree_w:
name: "Safety · Site-wide sign threshold (W) — measured, do not change"
description: "TWO OR MORE INVERTERS ONLY. The same 300 W as the single-inverter threshold, CARRIED ACROSS DELIBERATELY (SAFETY-30): the argument behind it does not depend on how many inverters there are - near zero the sign is noise, the deadband is 15 W, and there is one meter whatever is behind it. Do not change it without a capture that says so."
site_sign_disagree_s:
name: "Safety · Site-wide sign hold (s) — derived, do not change"
description: "TWO OR MORE INVERTERS ONLY. DERIVED FROM 1890 CLOSED-LOOP TEST RUNS (SAFETY-30), and deliberately NOT carried across from the single-inverter 180 s. On those runs the worst legitimate opposition at 300 W is 110 s with one inverter and 215 s with two, because the command has to travel the whole site rail at a slew rate that is not the site's - so carrying 180 s across would have shipped a false trip reachable at the lowest gain and slew with an ordinary 2.2 kW load reversal. 325 s is 1.51 times that, still inside the 900 s billing quarter, and still inside every episode of the captured fault day. Do not change it without re-deriving it."
meter_freeze_s:
name: "Safety · Frozen-meter alarm after (s) — measured, do not change"
description: "MEASURED, NOT CHOSEN (SAFETY-18). How long the meter may keep answering with an UNCHANGED reading, while the command stands at the rail, before the add-on raises an alarm. Over 2399 s of this house at its settled operating point - 1194 polls, 735 of them repeating the previous reading - the longest run without a distinct reading is 15.4 s; 300 s is 19.5 times that and still inside the 900 s billing quarter. ALARM ONLY: it does not command 0 W and does not latch. ⚠️ Only the homewizard_local meter source can see this at all; on every other source the status page says NOT COVERED rather than armed. Do not change it without re-deriving it."
circulation_w:
name: "Safety · Circulating-power threshold (W) — measured, do not change"
description: "TWO OR MORE INVERTERS ONLY; with one inverter the quantity is identically zero. Two inverters pushing against each other net out to zero at the meter and are invisible to every other guard in this add-on. MEASURED ON 924 CLOSED-LOOP TEST RUNS in which nothing was faulty (SAFETY-31): the worst legitimate opposition collapses from 505 s at a 100 W threshold to 5 s at 400 W, and 400 W is the sharp knee this add-on will not let you go below - under it, ordinary operation holds the sensor over the threshold for minutes and nothing shorter than the billing quarter could tell that from a fault. 700 W is 1.75 times the knee, and the extra margin is there because the second inverter's ramp and lag are still copied from the first one rather than measured. Do not change it without re-deriving it."
circulation_hold_s:
name: "Safety · Circulating-power hold (s) — derived, do not change"
description: "TWO OR MORE INVERTERS ONLY. DERIVED (SAFETY-31): 75 s is fifteen control cycles - 15 times the worst legitimate episode the rig can produce, 2.5 times the firmware's own 30 s link veto, and twelve times inside the 900 s billing quarter. It is deliberately not a round 60 or 120, which would be a guess wearing a measurement's clothes. Do not change it without re-deriving it."
auto_start:
name: "Advanced · Start controlling automatically on boot"
description: "Off by default. Leave it off until the site has been commissioned: with it off, somebody has to press Start after every restart of the add-on, which is what you want while you are still checking signs and entities."
gain:
name: "Advanced · Loop gain"
description: "How much of the remaining error the loop corrects each cycle. MEASURED ON REAL HARDWARE and already at the limit - do not raise it. Lower is slower and safer."
slew_w:
name: "Advanced · Largest change per cycle (W)"
description: "How far the setpoint may move in one control cycle. It bounds how fast the site can turn around, and several safety windows were measured across the whole range this accepts."
deadband_w:
name: "Advanced · Deadband (W)"
description: "Errors smaller than this are ignored. ⚠️ The deadband is a one-way ratchet: any resting point inside it holds forever, and the meter's import register counts every positive watt with no export to cancel it - which is exactly why the resting point below is slightly negative."
target_grid_w:
name: "Advanced · Resting point at the meter (W)"
description: "What the meter should sit at when nothing is happening; negative means a slight export. -10 W is deliberate: resting at 0 W leaks about half the deadband in billed import all day - roughly 0.2 to 0.35 kWh at a 15 W deadband - and biasing the rest point below zero moves that leak into the export register, which is not billed. It costs about this many watts of given-away export, so keep it small."
step_w:
name: "Advanced · Setpoint quantisation (W)"
description: "The setpoint is rounded to a multiple of this before it is written, so the inverter is not handed a new number for every watt of noise."
saturation_w:
name: "Advanced · Saturation threshold (W)"
description: "The gap between what was commanded and what the inverter delivers that counts as 'this inverter is at a limit'. ⚠️ The per-inverter sign threshold under Safety is derived as exactly half of this, so moving this moves that measurement's argument with it."
saturation_cycles:
name: "Advanced · Saturated cycles before freezing (count)"
description: "How many consecutive saturated cycles before the loop stops winding up. ⚠️ Do not set this to 1: a single noisy cycle would then freeze the loop."
integrator_max_w:
name: "Advanced · Integrator bound (W, 0 means the same as the rating)"
description: "Caps how much stale error can be waiting to unwind when the sign flips. MEASURED on the closed-loop simulator with a 4000 W load dropped to zero: at a bound equal to the rating the command is 1000 W two cycles later, at 1.5 times the rating it is 1800 W. ⚠️ Do not raise it above the inverter rating - the output clamp already bounds what reaches the wire, so extra headroom buys nothing but wrong-direction watts after every saturation event. Lowering it below the rating is the useful direction, and the only reason this is a separate setting."
heartbeat_s:
name: "Advanced · Setpoint refresh interval (s)"
description: "How often the setpoint is rewritten even when it has not changed. It must stay well under the firmware's own watchdog, which vetoes a link that has been quiet for 30 s."
stale_input_s:
name: "Advanced · Command 0 W after inputs missing for (s)"
description: "How long the inputs may be missing before the add-on commands 0 W. With a P1 meter this clock starts only AFTER the meter staleness limit has already expired, so the two stack: the total is longer than this number on its own."
cycle_floor_s:
name: "Advanced · Longest gap between control cycles (s)"
description: "A deadline on the gap between cycles, reset by every cycle. On a healthy meter it never elapses and changes nothing. Raise it only if your meter is slower than about 10 s, and keep it under the meter staleness limit - past that there is no reading left to evaluate anyway."
log_level:
name: "Advanced · Log level"
description: "How much detail the add-on writes to its log. 'info' is the shipped setting; 'debug' and 'trace' are for diagnosing a problem and are noisy."
+255
View File
@@ -0,0 +1,255 @@
# Home Assistant add-on-vertalingen - NEDERLANDS (UX-01)
#
# ⚠️ DIT IS GEEN WOORD-VOOR-WOORDVERTALING VAN en.yaml en hoort dat ook niet te
# zijn. De eigenaar draait Home Assistant op Europe/Brussels; dit is de tekst
# die een Vlaamse huiseigenaar leest, met de woorden die op zijn factuur en op
# zijn digitale meter staan: afname en injectie, kwartierpiek en
# capaciteitstarief, laadniveau, uitschakelgrens.
#
# ⚠️ DE TERUGVAL IS PER SLEUTEL. De frontend probeert eerst de taal van de
# gebruiker, dan `en`, dan de kale sleutelnaam. Een sleutel die HIER ONTBREEKT
# valt dus netjes terug op het Engels; een sleutel die hier STAAT maar fout is,
# valt nergens op terug. Een half vertaalde sleutel weglaten is beter dan hem
# verkeerd invullen.
#
# ⚠️ DE VOLGORDE WORDT HIER NIET BEPAALD. Het tabblad Configuratie rendert in de
# volgorde van het `schema:`-blok van config.yaml; de volgorde hieronder is
# alleen een spiegel daarvan, zodat beide bestanden gelijk lezen.
#
# ⚠️ AFGELEIDE CONSTANTEN VERMELDEN WAAR ZE VANDAAN KOMEN. Het tabblad toont een
# getal dat uit 1890 gesloten-lustests komt en het omvormervermogen van de
# eigenaar als hetzelfde soort veld. De beschrijving is de enige plek waar dat
# verschil gezegd kan worden.
configuration:
setpoint_entity:
name: "Hardware · Setpoint-entiteit van de omvormer"
description: "De ESPHome number-entiteit waar deze add-on het vermogen naartoe schrijft, meestal number.*_goodwe_setpoint_w. Dit is het enige wat de add-on aanstuurt. Laat leeg als u hieronder de lijst met omvormers invult: een installatie met een lijst mag niet óók één losse aansturing hebben, en de add-on start dan niet op."
soc_entity:
name: "Hardware · Entiteit met het laadniveau van de batterij (%)"
description: "De sensor die de laadtoestand van de batterij in procent doorgeeft. Gebruik de meting van de ESP32 zelf, geen waarde die elders berekend wordt. De onderhoudscyclus en alle ondergrenzen voor het laadniveau lezen deze sensor."
batt_entity:
name: "Hardware · Entiteit met het batterijvermogen (W)"
description: "De sensor die het batterijvermogen van deze omvormer doorgeeft, positief bij ontladen. Op deze installatie is dat holding register 0x0518, uitgelezen door de ESP32. Zowel de tekenbewaking als het alarm voor rondpompend vermogen beoordelen de omvormer aan de hand van deze meting."
batt_invert:
name: "Hardware · Teken van het batterijvermogen omkeren"
description: "Zet dit alleen aan als uw sensor ontladen als een negatief getal doorgeeft. De add-on gaat ervan uit dat positief ontladen betekent."
inverters:
name: "Hardware · Lijst met omvormers (leeg laten bij één omvormer)"
description: "Laat dit leeg tenzij er echt meer dan één omvormer staat. LEEG BETEKENT NIET 'nog niet ingesteld': het betekent dat de vier entiteiten hierboven, samen met het omvormervermogen en de uitschakelgrens van de batterij onder Grenzen, de ene omvormer beschrijven die u hebt. Dat is wat elke bestaande installatie leest, zonder dat iemand iets hoeft aan te passen. Vult u de lijst wel in, dan VERVANGT die de instellingen hierboven in plaats van ze aan te vullen, en wordt er niets overgenomen: elk item moet zijn eigen aansturing, zijn eigen vermogen en zijn eigen uitschakelgrens vermelden, zodat geen enkele omvormer ooit beoordeeld wordt op de cijfers van een andere. De losse setpoint-entiteit hierboven moet dan leeg blijven."
fields:
name:
name: "Naam"
description: "Een korte aanduiding voor deze omvormer, bijvoorbeeld inverter-a. Ze geeft deze omvormer een eigen naamruimte voor haar veiligheidsvergrendeling, hartslag en schrijfadministratie in het statusbestand van de add-on, dus twee omvormers mogen er niet één delen."
setpoint_entity:
name: "Setpoint-entiteit"
description: "De eigen ESPHome-entiteit number.*_goodwe_setpoint_w van deze omvormer. Twee items mogen niet dezelfde entiteit noemen - twee schrijvers op één aansturing wordt bij het opstarten geweigerd."
max_w:
name: "Vermogen van deze omvormer (W)"
description: "De bewaakte bovengrens van wat er naar DEZE omvormer geschreven mag worden; het plafond van de installatie is de som over de lijst. Verplicht bij elk item: een item zonder deze waarde zou een vermogen moeten lenen, en een omvormer beoordelen op de cijfers van een andere is precies de fout die deze lijst per omvormer moet wegnemen."
bms_soc_floor:
name: "Uitschakelniveau van de batterij (%)"
description: "Het percentage waarbij het batterijmanagementsysteem van DEZE batterij uitschakelt. Lees dit af van de batterij die er werkelijk staat (register 0x0560) voordat die batterij ooit aangestuurd wordt; neem geen waarde van een andere omvormer over. Bewust verplicht bij elk item: optioneel maken zou neerkomen op een standaardwaarde, en één standaardwaarde voor twee verschillende batterijen beschermt de kleinste batterij met het getal van de grootste."
soc_entity:
name: "Entiteit met het laadniveau (%) (optioneel)"
description: "Het laadniveau van deze batterij zelf. Laat leeg als deze omvormer dat niet doorgeeft - dat is wat het betekent, en er wordt nooit teruggevallen op de sensor van een andere omvormer."
batt_entity:
name: "Entiteit met het batterijvermogen (W) (optioneel)"
description: "Het batterijvermogen van deze omvormer zelf, positief bij ontladen. Laat leeg als deze omvormer dat niet doorgeeft; er wordt niets van een ander item overgenomen."
batt_invert:
name: "Teken van het batterijvermogen omkeren (optioneel)"
description: "Alleen voor dit item: zet dit aan als de sensor van deze omvormer ontladen als een negatief getal doorgeeft."
estop_fitted:
name: "Hardware · RS485-noodstop is geplaatst"
description: "Of de RS485-noodstop fysiek geïnstalleerd is. Dit stuurt alleen de waarschuwingsbalk op de statuspagina aan en verandert niets aan de regeling."
meter_source:
name: "Meter · Waar de meterstand vandaan komt"
description: "'off' houdt de losse Home Assistant-entiteit hieronder aan, waar een bestaande installatie op draait tot u iets anders kiest. ha_dsmr luistert mee met de DSMR-integratie; mqtt_p1 leest een MQTT-topic; ha_signed leest één entiteit met teken, wat een HomeWizard P1 publiceert; homewizard_local bevraagt de lokale API van de meter zelf en slaat Home Assistant helemaal over. ⚠️ Alleen homewizard_local kan 'de meter heeft niet geantwoord' onderscheiden van 'de waarde is niet veranderd', en is dus de enige bron waarop het alarm voor een vastgelopen meter iets betekent."
meter_entity:
name: "Meter · Entiteit met het netvermogen (W)"
description: "De sensor met het netto netvermogen, gebruikt wanneer de meterbron 'off' is. POSITIEF MOET AFNAME VAN HET NET BETEKENEN. Staat dit omgekeerd, dan stuurt de regeling de batterij de verkeerde kant op; gebruik daarvoor de tekenschakelaar hieronder en geen template-sensor."
meter_invert:
name: "Meter · Teken van het netvermogen omkeren"
description: "Zet dit aan als uw netsensor afname van het net als een negatief getal doorgeeft."
meter_phases:
name: "Meter · Aantal fasen (1 of 3)"
description: "Moet overeenkomen met uw aansluiting. Een telegram met een ander aantal fasen wordt bij binnenkomst geweigerd en gelogd, zodat een verkeerde waarde meteen zichtbaar wordt als 'geen telegrammen aanvaard' in plaats van als een stil verkeerd getal. Het bereik aanvaardt 2, maar dat is geen echte Belgische aansluiting."
p1_host:
name: "Meter · Adres van de HomeWizard P1"
description: "Alleen voor meterbron homewizard_local: het adres van de meter zelf op uw netwerk, als host of host:poort, bijvoorbeeld 192.168.2.250."
meter_poll_s:
name: "Meter · Seconden tussen twee uitlezingen"
description: "Alleen voor meterbron homewizard_local. 5 s is het tempo waarin de meter zelf ververst, dus lager instellen levert niets op. Deze waarde moet ruim onder de verouderingsgrens hieronder blijven - de meting is nooit verser dan dit interval - en de add-on start niet op als ze eraan gelijk is of erboven ligt."
meter_max_age_s:
name: "Meter · Een meting is verouderd na (s)"
description: "Daarna geldt de netwaarde als ontbrekend. Op zichzelf stuurt dit nog geen 0 W aan: de teller 'invoer ontbreekt' onder Geavanceerd begint pas te lopen nadat deze verstreken is, en de twee stapelen. 30 s is zes uitlezingen speling bij het standaard uitleesinterval."
meter_mqtt_topic:
name: "Meter · MQTT-topic"
description: "Alleen voor meterbron mqtt_p1: het topic waarop de P1-metingen gepubliceerd worden."
p1_import_entity:
name: "Meter · Entiteit van het afnameregister (W)"
description: "Het afnameregister ZONDER teken. Wijs dit niet aan een template-sensor mét teken toe: de add-on berekent het nettovermogen zelf als afname min injectie, zodat de tekenafspraak in geteste code zit en niet in ongecontroleerde YAML."
p1_export_entity:
name: "Meter · Entiteit van het injectieregister (W)"
description: "Het injectieregister ZONDER teken, de tegenhanger van het afnameregister hierboven. Zelfde regel: geen template-sensor mét teken."
p1_net_entity:
name: "Meter · Entiteit met het nettovermogen mét teken (W)"
description: "Alleen voor meterbron ha_signed. ÉÉN sensor mét teken: positief is afname van het net, negatief is injectie. Splits die niet in twee template-sensoren op - de add-on doet die splitsing zelf, juist zodat ze getest is."
p1_phase_import_entities:
name: "Meter · Afname-entiteiten per fase (L1, L2, L3)"
description: "Optioneel, in de volgorde L1..L3. Nodig voor de kwartierpiek van het capaciteitstarief op een driefasige aansluiting. Het aantal items moet gelijk zijn aan het aantal fasen hierboven."
p1_phase_export_entities:
name: "Meter · Injectie-entiteiten per fase (L1, L2, L3)"
description: "Optioneel, in de volgorde L1..L3, naast de afname-entiteiten per fase hierboven. Het aantal items moet gelijk zijn aan het aantal fasen."
p1_phase_net_entities:
name: "Meter · Netto-entiteiten per fase mét teken (L1, L2, L3)"
description: "Alleen voor meterbron ha_signed. Optioneel, in de volgorde L1..L3, elk met hetzelfde teken als de netto-entiteit hierboven. Zelfde rol als de afname- en injectie-entiteiten per fase: de kwartierpiek van het capaciteitstarief op een driefasige aansluiting. Het aantal items moet gelijk zijn aan het aantal fasen."
max_w:
name: "Grenzen · Vermogen van de omvormer (W)"
description: "DIT IS UW GETAL, geen afgeleide waarde: de harde bovengrens van wat er ooit gestuurd mag worden, in watt. Zet het op wat uw omvormer werkelijk aankan, begin laag en verhoog het pas na de indienstname. Het wordt helemaal niet gelezen zodra de lijst met omvormers is ingevuld - elk item draagt dan zijn eigen waarde en het plafond van de installatie is hun som. Verschillende veiligheidsdrempels moeten eronder blijven; de add-on start niet op als er één niet aan voldoet."
bms_soc_floor:
name: "Grenzen · Uitschakelniveau van de batterij (%)"
description: "GEMETEN, niet gekozen: het percentage waarbij het batterijmanagementsysteem van de batterij ZELF stopt met ontladen, wat u hier ook instelt. Register 0x0560 leest 10 op de referentie-GW5000S-BP. Lees deze waarde af van de batterij die er werkelijk staat in plaats van dit getal over te nemen. Ze staat hier zodat de add-on een ondergrens voor de piekbewaking op of onder deze waarde kan weigeren: zo'n ondergrens kan nooit werken, het BMS wint altijd eerst, en de statuspagina zou een reserve tonen die niet bestaat. Wordt niet gelezen zodra de lijst met omvormers is ingevuld - elk item vermeldt dan de uitschakelgrens van zijn eigen batterij."
peak_cap_w:
name: "Grenzen · Streefwaarde capaciteitstarief (W)"
description: "DIT IS UW GETAL: het gemiddelde kwartiervermogen waar de piekbewaking onder probeert te blijven. Neem het over uit uw netcontract - in België is dit de kwartierpiek waarop het capaciteitstarief van uw distributiefactuur berekend wordt."
peak_forecast_entity:
name: "Grenzen · Entiteit met de kwartierprognose (W)"
description: "Optioneel. Een prognose van het gemiddelde vermogen in het lopende factuurkwartier. Laat u dit leeg, dan is er helemaal geen piekbegrenzing."
peak_soc_floor:
name: "Grenzen · Piekbewaking ontlaadt niet onder (%)"
description: "AFGELEID, niet gekozen (SAFETY-24): de referentiebatterij heeft 13,8 kWh bruikbaar en de zwaarste doorgerekende afvlakdag vraagt 878 Wh, oftewel 6,4 %, dus 20 % ligt tien punten boven de uitschakelgrens van de batterij zelf en laat de bewaking nog ongeveer 1,6 van haar zwaarste waargenomen dagen speling. ⚠️ DIT BEGRENST ALLEEN DE PIEKBEWAKING. Het is geen reserve voor de hele batterij: gewoon eigenverbruik ontlaadt er dwars doorheen en gaat door tot aan de uitschakelgrens van de batterij, en dit getal verhogen verandert daar geen tiende procent aan. Het moet strikt boven de uitschakelgrens van de batterij blijven, anders start de add-on niet op. Verander het niet zonder de afleiding opnieuw te maken."
price_provider:
name: "Tarief · Bron van dynamische prijzen"
description: "Waar day-ahead- of realtimeprijzen vandaan komen. 'off' is de standaardinstelling en betekent dat deze installatie op het vaste tarief hieronder draait, zonder handel. ⚠️ Dit vandaag aanzetten haalt prijzen op, controleert en publiceert ze, en verandert geen enkele energiebeslissing - er is nog niets dat de prijsreeks gebruikt. Het mag niet gecombineerd worden met de twee oude Home Assistant-prijsentiteiten verderop: twee prijsbronnen op één installatie, waarvan er stilzwijgend één wint, wordt bij het opstarten geweigerd in plaats van schijnbaar actief gelaten."
price_markup_eur_kwh:
name: "Tarief · Marge van de leverancier (EUR/kWh)"
description: "De marge van uw energieleverancier. De add-on telt die ALLEEN op wanneer de gekozen prijsbron ze niet al bevat - bij engie_dynamic, totalenergies_dynamic, eneco_eddy en manual_csv wordt ze genegeerd, en dat wordt ook gelogd, zodat ze nooit dubbel wordt aangerekend."
price_taxes_eur_kwh:
name: "Tarief · Heffingen en btw (EUR/kWh)"
description: "Belastingen en heffingen per kWh, opgeteld volgens dezelfde regel als de marge: alleen wanneer de gekozen prijsbron ze nog niet bevat."
export_price_eur_kwh:
name: "Tarief · Injectievergoeding (EUR/kWh)"
description: "Wat u krijgt voor een kWh die u op het net zet, alles inbegrepen. Eén getal en geen reeks: geen enkele leverancier hier publiceert een dynamische injectiecurve. In België ligt dit vaak dicht bij nul, wat op zich al sterk pleit voor eigenverbruik in plaats van injectie. De waarde mag negatief zijn - op een zomerse middag betaalt u soms om te injecteren."
static_profile:
name: "Tarief · Vast of dag/nacht-tarief (één regel JSON)"
description: "Uw vaste of dag/nacht-contract, geschreven als één regel JSON. AANBEVOLEN ZELFS BIJ EEN DYNAMISCH CONTRACT: hierop valt de add-on terug wanneer de prijsfeed uitvalt, en staat dit leeg dan blijft de installatie bij een dode feed helemaal zonder tarief achter. De periodes moeten elk dagtype precies één keer bedekken, zonder gat en zonder overlap - een gat wordt bij het opstarten geweigerd in plaats van opgevuld, want een verzonnen prijs is er één waarop een strategie zou handelen. Een volledig vast tarief is één periode van 00:00 tot 24:00 op alle dagen. De prijzen zijn ALLES INBEGREPEN; de marge en heffingen hierboven worden er niet bij opgeteld. Let op: een venster van 22:00 tot 07:00 voor ma-vr dekt zaterdagochtend NIET, dus een regel voor het weekend is noodzakelijk en niet decoratief."
price_csv_path:
name: "Tarief · CSV-bestand met prijzen"
description: "Alleen voor prijsbron manual_csv: waar in /share de add-on uw eigen prijsbestand leest."
price_feed_url:
name: "Tarief · Afwijkende URL voor de prijsfeed"
description: "Laat leeg om de eigen feed van de gekozen bron te gebruiken. Alleen een host die die bron zelf opgeeft, wordt aanvaard, zodat dit niet zomaar ergens naar kan verwijzen."
price_horizon_h:
name: "Tarief · Hoe ver vooruit prijzen ophalen (uren)"
description: "Hoeveel uur aan prijzen er bij de bron opgevraagd wordt."
price_timeout_s:
name: "Tarief · Time-out voor een prijsaanvraag (s)"
description: "Hoe lang één aanvraag bij de prijsbron mag duren voordat ze wordt opgegeven."
price_now_entity:
name: "Tarief · Entiteit met de huidige prijs (oudere prijsweg)"
description: "De oudere manier om aan een prijs te komen, behouden omdat ze weghalen de onderhoudscyclus op een draaiende installatie zijn enige prijssignaal zou afnemen. De add-on leest deze entiteit en het gemiddelde hieronder en leidt er precies één ding uit af - of het nu goedkoper is dan gemiddeld - wat alleen gebruikt wordt om tijdens de onderhoudscyclus in een goedkoop venster te laden. Mag niet gecombineerd worden met een dynamische prijsbron."
price_avg_entity:
name: "Tarief · Entiteit met de gemiddelde prijs (oudere prijsweg)"
description: "Het gemiddelde waarmee de huidige prijs vergeleken wordt. Alleen zinvol samen met de entiteit hierboven en, net als die, niet te combineren met een dynamische prijsbron."
arbitrage_enabled:
name: "Tarief · Handelen op het prijsverschil"
description: "Laden in het goedkoopste gepubliceerde uur en ontladen in het duurste, maar alleen wanneer het verschil de kosten van de volledige cyclus dekt. STAAT UIT in de standaardinstelling, met opzet: dit is de eerste strategie in de add-on die bewust energie tegen de meter in verplaatst, dus ze wordt bewust aangezet of helemaal niet. Ze heeft zowel een prijsbron als een P1-meter nodig, en de add-on weigert combinaties die niet kunnen werken in plaats van ze schijnbaar actief te laten."
cycle_cost_threshold_eur:
name: "Tarief · Kostprijs van één volledige laad/ontlaadcyclus (EUR/kWh)"
description: "Wat één volledige cyclus per kWh kost: slijtage van de batterij plus omzettingsverliezen. Een prijsverschil dat hier onder ligt, kost geld en levensduur en wordt dus niet verhandeld. ⚠️ DIT GETAL IS NIET AFGELEID UIT EEN METING. 0,10 is een productbeslissing en staat nog open bij de eigenaar (OPT-08). Bij deze waarde handelt een installatie met een vast dag/nachttarief helemaal niet - het realistische Belgische dag/nachtverschil is ongeveer 0,08 EUR/kWh - en dat is bij dit getal het juiste antwoord, geen fout."
arbitrage_soc_floor:
name: "Tarief · Handel ontlaadt niet onder (%)"
description: "De reserve die de prijshandel niet mag aanspreken. Bewust een andere instelling dan de ondergrens van het onderhoud: een handelsstrategie op de cijfers van de maandelijkse balanceercyclus richten, zou twee ongerelateerde keuzes aan één getal koppelen."
arbitrage_soc_ceiling:
name: "Tarief · Handel laadt niet boven (%)"
description: "De ruimte die de prijshandel niet mag volmaken. De tegenhanger van de ondergrens hierboven, en om dezelfde reden losgehouden van het onderhoudsdoel."
maintenance_enabled:
name: "Onderhoud · Maandelijkse batterijcyclus uitvoeren"
description: "Een bewuste diepe ontlading, gevolgd door volledig opladen en een rustperiode op vol, zodat het batterijmanagementsysteem zijn schatting van het laadniveau kan herijken en de cellen kan balanceren. Staat standaard uit."
maintenance_interval_days:
name: "Onderhoud · Minimum aantal dagen tussen cycli"
description: "De kortste tijd tussen twee onderhoudscycli."
maintenance_start_hour:
name: "Onderhoud · Uur waarop een geplande cyclus start"
description: "Lokaal uur, 0 tot 23, waarop een cyclus die aan de beurt is begint."
maintenance_discharge_w:
name: "Onderhoud · Ontlaadvermogen (W)"
description: "Hoe snel de cyclus de batterij leegtrekt; het overschot gaat naar het net. Boven het vermogen van de omvormer wordt dit BEGRENSD tot dat vermogen en niet geweigerd - de cyclus loopt gewoon door, alleen trager, en de statuspagina meldt dat. Standaard 2000, afgestemd op het standaardvermogen; verhoog eerst het omvormervermogen en dan pas dit."
maintenance_charge_w:
name: "Onderhoud · Laadvermogen (W)"
description: "⚠️ MOET GELIJK AAN OF LAGER ZIJN dan het vermogen van de omvormer; anders start de add-on niet op. Erboven vraagt het laden in een goedkoop venster meer dan de bewaakte grens toelaat, lost de arbiter die tegenstrijdigheid op naar 0 W, en zou het onderhoud op een standaardinstallatie stilzwijgend nooit laden in een goedkoop venster. Daarnaast wordt dit nog eens begrensd door de ruimte die de piekbewaking overlaat."
maintenance_soc_floor:
name: "Onderhoud · Ontladen tot (%)"
description: "De diepte waar de maandelijkse herijking bewust naartoe gaat, één keer per maand, met opzet. ⚠️ DIT IS NIET DE ONDERGRENS VAN DE PIEKBEWAKING: die geeft aan hoe diep een besparende ontlading op geen enkele dag mag komen. De juiste waarden verschillen echt - 11 hier tegenover 20 daar - en daarom zijn het twee aparte instellingen die niet samengevoegd mogen worden."
maintenance_soc_target:
name: "Onderhoud · Opladen tot (%)"
description: "Het niveau waar de laadfase naartoe werkt voordat de rustperiode begint."
maintenance_hold_min:
name: "Onderhoud · Op vol houden gedurende (minuten)"
description: "Hoe lang er op het streefniveau gebleven wordt zodat het batterijmanagementsysteem het balanceren van de cellen kan afmaken."
sign_disagree_w:
name: "Veiligheid · Drempel tekenbewaking (W) — gemeten, niet wijzigen"
description: "GEMETEN, NIET GEKOZEN (SAFETY-02). Zowel het uitgestuurde setpoint als de netmeting moet boven deze waarde liggen voordat hun tegengestelde tekens überhaupt als onenigheid tellen. Op de vastgelegde gezonde dag (23-08-2026) komt het teken in 93,4 % van de beoordeelde metingen overeen; op de vastgelegde foutdag (20-08-2026) ligt dat tussen 0,0 en 10,5 %, met tegengestelde periodes tot 1752 s. Er is geen reden om hieraan te sleutelen zonder een nieuwe meetcampagne die dat onderbouwt. De waarde moet onder het omvormervermogen blijven, anders kan de bewaking nooit aanslaan, en de add-on weigert die instelling."
sign_disagree_s:
name: "Veiligheid · Wachttijd tekenbewaking (s) — gemeten, niet wijzigen"
description: "GEMETEN, NIET GEKOZEN (SAFETY-02). Hoe lang het setpoint en de meter onafgebroken tegengesteld moeten blijven voordat de add-on 0 W stuurt en vergrendelt tot iemand de regeling opnieuw start. 180 s ligt midden in een zeer brede gemeten marge: de langste terechte tegengestelde periode op de gezonde dag duurt 30 s, terwijl de foutdag bij 300 s nog altijd 13 keer aanslaat. Verander dit niet zonder nieuwe metingen."
unit_sign_disagree_w:
name: "Veiligheid · Tekendrempel per omvormer (W) — afgeleid, niet wijzigen"
description: "ALLEEN BIJ TWEE OF MEER OMVORMERS; bij één omvormer doet deze instelling niets. AFGELEID UIT 1890 GESLOTEN-LUSTESTS op de testopstelling met twee omvormers (SAFETY-30), waarbij niets defect was, over het volledige bereik dat deze add-on toelaat voor versterking en volgsnelheid. 250 W is precies de helft van de verzadigingsdrempel, zodat het kleinste verschil dat hier zichtbaar is, exact de afwijking is waarbij de regeling zelf al zegt dat de omvormer niet volgt. Verander dit niet zonder de afleiding opnieuw te maken. De waarde moet onder het omvormervermogen blijven, anders kan ze nooit aanslaan."
unit_sign_disagree_s:
name: "Veiligheid · Wachttijd per omvormer (s) — afgeleid, niet wijzigen"
description: "ALLEEN BIJ TWEE OF MEER OMVORMERS. AFGELEID UIT 1890 GESLOTEN-LUSTESTS (SAFETY-30): 85 s is 8,5 keer de langste terechte tegengestelde periode die die tests opleveren (10,0 s), 2,8 keer het eigen veto van 30 s in de firmware, en minder dan de helft van de 180 s die de installatiebrede controle neemt. Verander dit niet zonder de afleiding opnieuw te maken."
site_sign_disagree_w:
name: "Veiligheid · Tekendrempel voor de hele installatie (W) — gemeten, niet wijzigen"
description: "ALLEEN BIJ TWEE OF MEER OMVORMERS. Dezelfde 300 W als de drempel voor één omvormer, BEWUST OVERGENOMEN (SAFETY-30): de onderbouwing hangt niet af van het aantal omvormers - rond nul is het teken ruis, de dode zone is 15 W, en er is één meter, wat er ook achter hangt. Verander dit niet zonder metingen die dat onderbouwen."
site_sign_disagree_s:
name: "Veiligheid · Wachttijd voor de hele installatie (s) — afgeleid, niet wijzigen"
description: "ALLEEN BIJ TWEE OF MEER OMVORMERS. AFGELEID UIT 1890 GESLOTEN-LUSTESTS (SAFETY-30), en bewust NIET overgenomen van de 180 s voor één omvormer. In die tests duurt de langste terechte tegengestelde periode bij 300 W 110 s met één omvormer en 215 s met twee, omdat het commando de volledige installatiegrens moet doorlopen aan een volgsnelheid die niet die van de installatie is. 180 s overnemen zou dus een vals alarm hebben opgeleverd bij de laagste versterking en volgsnelheid en een gewone belastingomkering van 2,2 kW. 325 s is 1,51 keer die waarde, blijft binnen het factuurkwartier van 900 s en binnen elke episode van de vastgelegde foutdag. Verander dit niet zonder de afleiding opnieuw te maken."
meter_freeze_s:
name: "Veiligheid · Alarm vastgelopen meter na (s) — gemeten, niet wijzigen"
description: "GEMETEN, NIET GEKOZEN (SAFETY-18). Hoe lang de meter mag blijven antwoorden met een ONVERANDERDE waarde, terwijl het commando op de grens staat, voordat de add-on alarm slaat. Over 2399 s van deze woning op haar ingeregelde werkpunt - 1194 uitlezingen, waarvan 735 een herhaling van de vorige waarde - duurt de langste periode zonder een nieuwe waarde 15,4 s; 300 s is 19,5 keer zoveel en blijft binnen het factuurkwartier van 900 s. ALLEEN EEN ALARM: er wordt geen 0 W gestuurd en er wordt niets vergrendeld. ⚠️ Alleen de meterbron homewizard_local kan dit überhaupt zien; bij elke andere bron meldt de statuspagina NIET GEDEKT in plaats van actief. Verander dit niet zonder de afleiding opnieuw te maken."
circulation_w:
name: "Veiligheid · Drempel rondpompend vermogen (W) — gemeten, niet wijzigen"
description: "ALLEEN BIJ TWEE OF MEER OMVORMERS; bij één omvormer is deze grootheid altijd nul. Twee omvormers die tegen elkaar in duwen, heffen elkaar aan de meter op en zijn onzichtbaar voor elke andere bewaking in deze add-on. GEMETEN OVER 924 GESLOTEN-LUSTESTS waarbij niets defect was (SAFETY-31): de langste terechte tegenwerking valt terug van 505 s bij een drempel van 100 W naar 5 s bij 400 W, en 400 W is de scherpe knik waaronder deze add-on u niet laat gaan - daaronder houdt gewone werking de sensor minutenlang boven de drempel en kan niets korter dan het factuurkwartier dat van een storing onderscheiden. 700 W is 1,75 keer de knik; die extra marge is er omdat het aanloopgedrag van de tweede omvormer nog gekopieerd is van de eerste en niet gemeten. Verander dit niet zonder de afleiding opnieuw te maken."
circulation_hold_s:
name: "Veiligheid · Wachttijd rondpompend vermogen (s) — afgeleid, niet wijzigen"
description: "ALLEEN BIJ TWEE OF MEER OMVORMERS. AFGELEID (SAFETY-31): 75 s zijn vijftien regelcycli - 15 keer de langste terechte episode die de testopstelling kan produceren, 2,5 keer het eigen veto van 30 s in de firmware, en twaalf keer binnen het factuurkwartier van 900 s. Het is bewust geen ronde 60 of 120, want dat zou een gok zijn in het jasje van een meting. Verander dit niet zonder de afleiding opnieuw te maken."
auto_start:
name: "Geavanceerd · Automatisch beginnen te regelen bij opstarten"
description: "Staat standaard uit. Laat het uit tot de installatie in dienst is genomen: zolang het uit staat, moet iemand na elke herstart van de add-on op Start drukken, en dat is precies wat u wilt terwijl u tekens en entiteiten nog aan het nakijken bent."
gain:
name: "Geavanceerd · Versterking van de regellus"
description: "Welk deel van de resterende afwijking de regeling per cyclus wegregelt. GEMETEN OP ECHTE HARDWARE en al aan de bovengrens - niet verhogen. Lager is trager en veiliger."
slew_w:
name: "Geavanceerd · Grootste verandering per cyclus (W)"
description: "Hoeveel het setpoint in één regelcyclus mag verspringen. Dit begrenst hoe snel de installatie kan omkeren; verschillende veiligheidsvensters zijn over het volledige toegelaten bereik gemeten."
deadband_w:
name: "Geavanceerd · Dode zone (W)"
description: "Afwijkingen kleiner dan deze waarde worden genegeerd. ⚠️ De dode zone werkt maar één kant op: elk rustpunt erbinnen blijft eeuwig staan, en het afnameregister van de meter telt elke positieve watt mee zonder injectie die dat compenseert - en precies daarom staat het rustpunt hieronder licht negatief."
target_grid_w:
name: "Geavanceerd · Rustpunt aan de meter (W)"
description: "Waar de meter moet staan wanneer er niets gebeurt; negatief betekent een lichte injectie. -10 W is bewust gekozen: rusten op 0 W lekt de hele dag door ongeveer de helft van de dode zone aan gefactureerde afname - grofweg 0,2 tot 0,35 kWh bij een dode zone van 15 W - en het rustpunt onder nul leggen verplaatst dat lek naar het injectieregister, dat niet gefactureerd wordt. Het kost ongeveer evenveel watt weggegeven injectie, dus houd het klein."
step_w:
name: "Geavanceerd · Afronding van het setpoint (W)"
description: "Het setpoint wordt op een veelvoud hiervan afgerond voordat het geschreven wordt, zodat de omvormer niet voor elke watt ruis een nieuw getal krijgt."
saturation_w:
name: "Geavanceerd · Verzadigingsdrempel (W)"
description: "Het verschil tussen wat gevraagd werd en wat de omvormer levert dat geldt als 'deze omvormer zit aan een grens'. ⚠️ De tekendrempel per omvormer onder Veiligheid is afgeleid als precies de helft hiervan, dus deze waarde verschuiven, verschuift ook de onderbouwing daarvan."
saturation_cycles:
name: "Geavanceerd · Verzadigde cycli voor bevriezen (aantal)"
description: "Hoeveel opeenvolgende verzadigde cycli er nodig zijn voordat de regeling stopt met verder oplopen. ⚠️ Zet dit niet op 1: één ruiscyclus zou de regeling dan al bevriezen."
integrator_max_w:
name: "Geavanceerd · Begrenzing van de integrator (W, 0 betekent gelijk aan het vermogen)"
description: "Begrenst hoeveel oude afwijking er kan klaarstaan om af te bouwen wanneer het teken omslaat. GEMETEN op de gesloten-lussimulator met een belasting van 4000 W die naar nul valt: bij een grens gelijk aan het omvormervermogen staat het commando twee cycli later op 1000 W, bij anderhalf keer dat vermogen op 1800 W. ⚠️ Zet dit niet hoger dan het omvormervermogen - de uitgangsbegrenzing bepaalt toch al wat er naar de omvormer gaat, dus extra ruimte levert alleen watts in de verkeerde richting op na elke verzadiging. Lager zetten dan het omvormervermogen is de nuttige richting, en de enige reden dat dit een aparte instelling is."
heartbeat_s:
name: "Geavanceerd · Verversingsinterval van het setpoint (s)"
description: "Hoe vaak het setpoint opnieuw geschreven wordt, ook als het niet veranderd is. Dit moet ruim onder de eigen bewaking van de firmware blijven, die een verbinding die 30 s stil is geweest, blokkeert."
stale_input_s:
name: "Geavanceerd · 0 W sturen nadat invoer ontbreekt gedurende (s)"
description: "Hoe lang de invoer mag ontbreken voordat de add-on 0 W stuurt. Bij een P1-meter begint deze teller pas te lopen NADAT de verouderingsgrens van de meter al verstreken is, dus de twee stapelen: het totaal is langer dan dit getal op zich."
cycle_floor_s:
name: "Geavanceerd · Langste tijd tussen twee regelcycli (s)"
description: "Een uiterste termijn voor de tijd tussen twee cycli, die door elke cyclus opnieuw begint. Bij een gezonde meter verstrijkt hij nooit en verandert hij niets. Verhoog hem alleen als uw meter trager is dan ongeveer 10 s, en houd hem onder de verouderingsgrens van de meter - daarna is er toch geen meting meer om te beoordelen."
log_level:
name: "Geavanceerd · Logniveau"
description: "Hoeveel detail de add-on naar zijn logboek schrijft. 'info' is de standaardinstelling; 'debug' en 'trace' dienen om een probleem te onderzoeken en leveren veel tekst op."