`bms_soc_floor` describes A BATTERY, not a site. At two packs of different models the cut-outs differ, and one number for both graded the shallower pack against the deeper one's BMS - so a site with cut-outs of 10 % and 30 % under `peak_soc_floor: 20` STARTED, and the guard would command a forced discharge that pack B's BMS, not the operator's floor, is the thing that stops. That is rule 8's own failure mode, reached through rule 8. Scoped to the card's third bullet, per its PM PROOFREAD: the aggregate anti-windup (DEV-02) and per-instance `achievable_w` (CFG-04) were verified as already shipped and are untouched. * config.yaml: `bms_soc_floor: int(0,50)` REQUIRED per `inverters:` entry. Nothing is inherited; the flat key stays the single-inverter shape's own cut-out. A per-entry DEFAULT was declined - a default is one number for every pack, which is this card's defect - and the decision is recorded. * inverter.py: `Inverter.bms_soc_floor`; an entry that states none gets None, not a borrowed number and not 0.0 (the most permissive value the key has). * peakguard.py: `Pack`, `pack_floor_pct()`, `pack_permissions()`, `binding_soc_floor()`. `discharge_permitted()` is unchanged and is still the one place the question is answered. * validate.py: `unit_bms_floors_indexed()` carries the ROSTER index; rule 8 grades EVERY unit and NAMES the one it refuses. Graded with the offender SECOND and with the same two numbers in the other order. * main.py: `Controller.packs`; `decide(soc_floor=...)` is the per-pack reduction of the same option; the floor-limited notification names the pack that stopped the site. `pack_floor_soc` - the emptiest pack, and its None-on-missing behaviour - is untouched. * tools/supervisor_shape_probe.py: RE-RUN and repaired. The required key broke §C and left §D printing PASS on a refusal about a different key. §D is now an isolated counterfactual over an accepted merged baseline, one key varied, asserting the key name. `all cases passed` on 2026.08.0. Stated rather than hidden: under any config rule 8 accepts the per-pack FLOOR reduces to `peak_soc_floor` for every pack. The reduction is written for `unit_caps_indexed()`'s reason and graded on both sides - 1775 rule-8-valid pairs answer the option, the pair rule 8 refuses answers the cut-out. `peak_soc_floor` is still one number for the site, so the "deeper pack needlessly withheld" half is filed as an open question, not closed. Full 19-file suite green. Twelve source mutations through tools/mutation_run.sh: eleven red, one argued survivor. The battery also found `_flat_bms_floor()` defaulting in two places, each covering for the other. No measurement of inverter B appears anywhere: it does not exist yet. Every second-pack figure is simulated and labelled. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
committed by
glenn schrooyen
co-authored by
Claude Opus 5
parent
67e649ad6b
commit
f9e7fbf86d
@@ -204,12 +204,17 @@ check("...and the refusal names the actuator and every writer aimed at it, so "
|
||||
_PER_INVERTER_OK = {k: v for k, v in base().items() if k != "setpoint_entity"}
|
||||
_PER_INVERTER_OK["inverters"] = [
|
||||
{"name": "inverter-a", "setpoint_entity": "number.goodwe_setpoint",
|
||||
"max_w": 2000},
|
||||
"max_w": 2000, "bms_soc_floor": 10},
|
||||
# ⚠️ INVERTER B DOES NOT EXIST. 2000 W here is the SHIPPED default repeated,
|
||||
# not a rating measured off a second device - SPIKE-04 measures that when
|
||||
# there is one to measure. Nothing in this file depends on the number.
|
||||
# ⚠️ SAFETY-32 made `bms_soc_floor` a REQUIRED per-entry key, and the two
|
||||
# values here DIFFER (10 / 15) rather than being copied. 15 % is SIMULATED -
|
||||
# there is no second pack to read a cut-out off - and the reason it is not
|
||||
# simply 10 is MUTATION.md habit 1: a fixture whose two per-unit numbers are
|
||||
# equal cannot show a check reading the wrong unit's.
|
||||
{"name": "inverter-b", "setpoint_entity": "number.goodwe_setpoint_b",
|
||||
"max_w": 2000}]
|
||||
"max_w": 2000, "bms_soc_floor": 15}]
|
||||
check("two inverters with their own entities are ACCEPTED - one writer each, "
|
||||
"no shared actuator, and that is CFG-04's whole purpose",
|
||||
validate_startup_config(_PER_INVERTER_OK, -5000, 5000) == [])
|
||||
|
||||