SAFETY-32: bms_soc_floor per pack, rule 8 per unit
`bms_soc_floor` describes A BATTERY, not a site. At two packs of different models the cut-outs differ, and one number for both graded the shallower pack against the deeper one's BMS - so a site with cut-outs of 10 % and 30 % under `peak_soc_floor: 20` STARTED, and the guard would command a forced discharge that pack B's BMS, not the operator's floor, is the thing that stops. That is rule 8's own failure mode, reached through rule 8. Scoped to the card's third bullet, per its PM PROOFREAD: the aggregate anti-windup (DEV-02) and per-instance `achievable_w` (CFG-04) were verified as already shipped and are untouched. * config.yaml: `bms_soc_floor: int(0,50)` REQUIRED per `inverters:` entry. Nothing is inherited; the flat key stays the single-inverter shape's own cut-out. A per-entry DEFAULT was declined - a default is one number for every pack, which is this card's defect - and the decision is recorded. * inverter.py: `Inverter.bms_soc_floor`; an entry that states none gets None, not a borrowed number and not 0.0 (the most permissive value the key has). * peakguard.py: `Pack`, `pack_floor_pct()`, `pack_permissions()`, `binding_soc_floor()`. `discharge_permitted()` is unchanged and is still the one place the question is answered. * validate.py: `unit_bms_floors_indexed()` carries the ROSTER index; rule 8 grades EVERY unit and NAMES the one it refuses. Graded with the offender SECOND and with the same two numbers in the other order. * main.py: `Controller.packs`; `decide(soc_floor=...)` is the per-pack reduction of the same option; the floor-limited notification names the pack that stopped the site. `pack_floor_soc` - the emptiest pack, and its None-on-missing behaviour - is untouched. * tools/supervisor_shape_probe.py: RE-RUN and repaired. The required key broke §C and left §D printing PASS on a refusal about a different key. §D is now an isolated counterfactual over an accepted merged baseline, one key varied, asserting the key name. `all cases passed` on 2026.08.0. Stated rather than hidden: under any config rule 8 accepts the per-pack FLOOR reduces to `peak_soc_floor` for every pack. The reduction is written for `unit_caps_indexed()`'s reason and graded on both sides - 1775 rule-8-valid pairs answer the option, the pair rule 8 refuses answers the cut-out. `peak_soc_floor` is still one number for the site, so the "deeper pack needlessly withheld" half is filed as an open question, not closed. Full 19-file suite green. Twelve source mutations through tools/mutation_run.sh: eleven red, one argued survivor. The battery also found `_flat_bms_floor()` defaulting in two places, each covering for the other. No measurement of inverter B appears anywhere: it does not exist yet. Every second-pack figure is simulated and labelled. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
committed by
glenn schrooyen
co-authored by
Claude Opus 5
parent
67e649ad6b
commit
f9e7fbf86d
@@ -203,6 +203,16 @@ A_ENT = {"setpoint_entity": "number.sp_a", "soc_entity": "sensor.soc_a",
|
||||
# realism they do not use. So: ILLUSTRATIVE, NOT B'S RATING, and not a
|
||||
# placeholder for it either - the placeholder era ended on 2026-09-04.
|
||||
B_RATING_HYPOTHESIS = 3000.0
|
||||
# SAFETY-32. Each pack's OWN BMS cut-out percent, now a REQUIRED roster key.
|
||||
# ⚠️ 10 IS MEASURED (register 0x0560 on the reference GW5000S-BP and the shipped
|
||||
# `bms_soc_floor` default); 15 IS SIMULATED - there is no second pack. They
|
||||
# DIFFER on purpose: a fixture whose two per-unit numbers are equal cannot show
|
||||
# a check that read the wrong unit's, which is MUTATION.md habit 1 and the defect
|
||||
# that has now bitten four consecutive cards. Both sit below the shipped
|
||||
# `peak_soc_floor` of 20, so rule 8 accepts this roster.
|
||||
A_BMS_FLOOR = 10
|
||||
B_BMS_FLOOR_SIM = 15
|
||||
|
||||
A_RATING = 5000.0
|
||||
|
||||
BASE_OPTS = dict(A_ENT, meter_source="off", meter_entity="sensor.grid",
|
||||
@@ -1418,13 +1428,16 @@ _TWO_OPTS.pop("batt_entity")
|
||||
_TWO_OPTS["inverters"] = [
|
||||
dict(name="inverter-a", setpoint_entity="number.sp_a",
|
||||
soc_entity="sensor.soc_a", batt_entity="sensor.batt_a",
|
||||
max_w=A_RATING),
|
||||
max_w=A_RATING, bms_soc_floor=A_BMS_FLOOR),
|
||||
# ⚠️ 3000 W IS A HYPOTHESIS AND IS MARKED AS ONE WHEREVER IT APPEARS. It is
|
||||
# here because it DIFFERS from A's 5000 W, which is the only property any
|
||||
# check below uses. SPIKE-04 measures the real device.
|
||||
# ⚠️ AND SO IS ITS 15 % CUT-OUT (SAFETY-32). There is no second pack to read
|
||||
# register 0x0560 off; the value is SIMULATED, and it differs from A's 10 %
|
||||
# for MUTATION.md habit 1's reason and no other.
|
||||
dict(name="inverter-b", setpoint_entity="number.sp_b",
|
||||
soc_entity="sensor.soc_b", batt_entity="sensor.batt_b",
|
||||
max_w=B_RATING_HYPOTHESIS),
|
||||
max_w=B_RATING_HYPOTHESIS, bms_soc_floor=B_BMS_FLOOR_SIM),
|
||||
]
|
||||
_c9, _hass9 = built(_TWO_OPTS)
|
||||
print(f" the roster built from `inverters:` -> {[repr(i) for i in _c9.inverters]}")
|
||||
@@ -1500,14 +1513,19 @@ _decl9 = dict(ln.strip().lstrip("- ").split(": ", 1)
|
||||
for ln in _entry9.splitlines()[1:] if ": " in ln)
|
||||
print(f" the shipped per-entry schema: {_decl9}")
|
||||
check("...and the schema half declares it as a LIST OF OBJECTS whose `name`, "
|
||||
"`setpoint_entity` and `max_w` are REQUIRED - no trailing `?` - so the "
|
||||
"Supervisor refuses a half-written entry before the add-on sees it, and "
|
||||
"an entry can never fall back on a sibling's rating because there is no "
|
||||
"entry without one",
|
||||
set(_decl9) == {"name", "setpoint_entity", "max_w", "soc_entity",
|
||||
"batt_entity", "batt_invert"}
|
||||
"`setpoint_entity`, `max_w` and `bms_soc_floor` are REQUIRED - no "
|
||||
"trailing `?` - so the Supervisor refuses a half-written entry before the "
|
||||
"add-on sees it, and an entry can never fall back on a sibling's rating "
|
||||
"or on a sibling's BMS cut-out because there is no entry without one. "
|
||||
"⚠️ SAFETY-32 ADDED THE FOURTH ONE AS REQUIRED RATHER THAN AS "
|
||||
"`int(0,50)?`, and the difference is the whole of that card: an optional "
|
||||
"per-pack cut-out is a DEFAULTED one, and a default is one number for "
|
||||
"two batteries - the shallower pack protected by the deeper pack's BMS",
|
||||
set(_decl9) == {"name", "setpoint_entity", "max_w", "bms_soc_floor",
|
||||
"soc_entity", "batt_entity", "batt_invert"}
|
||||
and not any(_decl9[k].endswith("?")
|
||||
for k in ("name", "setpoint_entity", "max_w"))
|
||||
for k in ("name", "setpoint_entity", "max_w",
|
||||
"bms_soc_floor"))
|
||||
and all(_decl9[k].endswith("?")
|
||||
for k in ("soc_entity", "batt_entity", "batt_invert")))
|
||||
|
||||
@@ -1589,9 +1607,11 @@ check("...and two inverters on two DIFFERENT entities are accepted, because "
|
||||
"that is the configuration this card exists for and a validator that "
|
||||
"fires on the legitimate case gets switched off",
|
||||
validate_startup_config(_opts(setpoint_entity="", inverters=[
|
||||
dict(name="inverter-a", setpoint_entity="number.sp_a", max_w=A_RATING),
|
||||
dict(name="inverter-a", setpoint_entity="number.sp_a", max_w=A_RATING,
|
||||
bms_soc_floor=A_BMS_FLOOR),
|
||||
dict(name="inverter-b", setpoint_entity="number.sp_b",
|
||||
max_w=B_RATING_HYPOTHESIS)])) == [])
|
||||
max_w=B_RATING_HYPOTHESIS,
|
||||
bms_soc_floor=B_BMS_FLOOR_SIM)])) == [])
|
||||
|
||||
# --- the rest of rule 9 -------------------------------------------------------
|
||||
_p_flat = validate_startup_config(_opts(inverters=[
|
||||
|
||||