SAFETY-32: bms_soc_floor per pack, rule 8 per unit
`bms_soc_floor` describes A BATTERY, not a site. At two packs of different models the cut-outs differ, and one number for both graded the shallower pack against the deeper one's BMS - so a site with cut-outs of 10 % and 30 % under `peak_soc_floor: 20` STARTED, and the guard would command a forced discharge that pack B's BMS, not the operator's floor, is the thing that stops. That is rule 8's own failure mode, reached through rule 8. Scoped to the card's third bullet, per its PM PROOFREAD: the aggregate anti-windup (DEV-02) and per-instance `achievable_w` (CFG-04) were verified as already shipped and are untouched. * config.yaml: `bms_soc_floor: int(0,50)` REQUIRED per `inverters:` entry. Nothing is inherited; the flat key stays the single-inverter shape's own cut-out. A per-entry DEFAULT was declined - a default is one number for every pack, which is this card's defect - and the decision is recorded. * inverter.py: `Inverter.bms_soc_floor`; an entry that states none gets None, not a borrowed number and not 0.0 (the most permissive value the key has). * peakguard.py: `Pack`, `pack_floor_pct()`, `pack_permissions()`, `binding_soc_floor()`. `discharge_permitted()` is unchanged and is still the one place the question is answered. * validate.py: `unit_bms_floors_indexed()` carries the ROSTER index; rule 8 grades EVERY unit and NAMES the one it refuses. Graded with the offender SECOND and with the same two numbers in the other order. * main.py: `Controller.packs`; `decide(soc_floor=...)` is the per-pack reduction of the same option; the floor-limited notification names the pack that stopped the site. `pack_floor_soc` - the emptiest pack, and its None-on-missing behaviour - is untouched. * tools/supervisor_shape_probe.py: RE-RUN and repaired. The required key broke §C and left §D printing PASS on a refusal about a different key. §D is now an isolated counterfactual over an accepted merged baseline, one key varied, asserting the key name. `all cases passed` on 2026.08.0. Stated rather than hidden: under any config rule 8 accepts the per-pack FLOOR reduces to `peak_soc_floor` for every pack. The reduction is written for `unit_caps_indexed()`'s reason and graded on both sides - 1775 rule-8-valid pairs answer the option, the pair rule 8 refuses answers the cut-out. `peak_soc_floor` is still one number for the site, so the "deeper pack needlessly withheld" half is filed as an open question, not closed. Full 19-file suite green. Twelve source mutations through tools/mutation_run.sh: eleven red, one argued survivor. The battery also found `_flat_bms_floor()` defaulting in two places, each covering for the other. No measurement of inverter B appears anywhere: it does not exist yet. Every second-pack figure is simulated and labelled. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
committed by
glenn schrooyen
co-authored by
Claude Opus 5
parent
67e649ad6b
commit
f9e7fbf86d
@@ -132,7 +132,7 @@ NOT READY banner already names the problem, (b) does not apply.
|
||||
installed base is on a fixed or static tariff. Refusing to start without a
|
||||
price feed would lock those sites out of the add-on entirely.
|
||||
|
||||
8. `peak_soc_floor` at or below `bms_soc_floor`. [(a)]
|
||||
8. `peak_soc_floor` at or below `bms_soc_floor`, ON ANY UNIT. [(a)]
|
||||
SAFETY-24, and the same shape as 1, 4, 5 and 6. The peak guard can COMMAND
|
||||
a discharge to hold a billed quarter down (SAFETY-07), and `peak_soc_floor`
|
||||
is the EMS-side bound on how far down it may take the pack. The BMS has its
|
||||
@@ -142,6 +142,12 @@ NOT READY banner already names the problem, (b) does not apply.
|
||||
of binding while its status page reports one - rule 5's "a disarmed guard
|
||||
that advertises itself as armed", on the guard whose failure mode is a pack
|
||||
that is quietly never available when it is wanted.
|
||||
⚠️ SAFETY-32: `bms_soc_floor` DESCRIBES A BATTERY, so at a roster it is a
|
||||
per-entry key and this rule grades EVERY unit and NAMES the one it refuses.
|
||||
One number for two packs of different models refuses the wrong config and
|
||||
accepts the wrong one - cut-outs of 10 % and 30 % under `peak_soc_floor: 20`
|
||||
used to start. A missing per-entry cut-out is refused here rather than
|
||||
defaulted: a cut-out invented for a pack IS this defect.
|
||||
|
||||
⚠️ `<=`, NOT `<`, and the equality case is the interesting one. At exactly
|
||||
equal, the EMS floor and the pack's cut-out act at the same percent, so the
|
||||
@@ -386,6 +392,49 @@ def unit_caps_indexed(opts: dict) -> list[tuple[int, float]]:
|
||||
return caps
|
||||
|
||||
|
||||
def unit_bms_floors_indexed(opts: dict) -> list[tuple[int, object, object]]:
|
||||
"""SAFETY-32. Each pack's OWN `bms_soc_floor`, carrying its ROSTER INDEX.
|
||||
|
||||
`(roster index, the raw value as configured, the parsed float or None)`, one
|
||||
triple per unit. The raw value travels too because the refusal quotes what
|
||||
the operator actually wrote, and `!r` of a re-read `opts` key is the wrong
|
||||
string the moment the value came off a roster entry.
|
||||
|
||||
⚠️ THE INDEX IS THE ROSTER'S, NOT THIS LIST'S, AND THAT IS CFG-04'S BUG
|
||||
WRITTEN DOWN. Rules 5 and 6 fed a CAPS-list index into `_unit_label()`,
|
||||
which indexes the ROSTER, so on a roster whose first entry was malformed the
|
||||
refusal named the WRONG INVERTER - an operator sent to the wrong device by
|
||||
the very message that exists to stop that. `unit_caps_indexed()` exists
|
||||
because of it. This function goes one step further and SKIPS NOTHING: every
|
||||
entry produces a triple, including the ones with no usable floor, because a
|
||||
missing cut-out is itself what rule 8 has to refuse BY NAME. There is
|
||||
therefore no second list for an index to desynchronise from.
|
||||
|
||||
⚠️ AND NOTHING IS INHERITED. At a declared roster the FLAT `bms_soc_floor` is
|
||||
not read at all - CFG-04's rule, and this card's subject: a pack that borrows
|
||||
a sibling's cut-out is graded against a battery it is not. At the flat shape
|
||||
the flat key IS this one pack's cut-out, defaulted from CFG-03's single
|
||||
mirror exactly as `inverter._flat_bms_floor()` defaults it.
|
||||
"""
|
||||
entries = roster_entries(opts)
|
||||
if not entries:
|
||||
return [(0, opts.get("bms_soc_floor"),
|
||||
_number(opts, "bms_soc_floor",
|
||||
PEAK_OPTION_DEFAULTS["bms_soc_floor"]))]
|
||||
out: list[tuple[int, object, object]] = []
|
||||
for index, entry in enumerate(entries):
|
||||
if not isinstance(entry, dict):
|
||||
# Rule 9(a)/(b) already refuses a non-dict entry by index, and it
|
||||
# runs FIRST. Naming it twice would hand the operator two sentences
|
||||
# about one line of YAML.
|
||||
continue
|
||||
raw = entry.get("bms_soc_floor")
|
||||
out.append((index, raw,
|
||||
None if raw is None or raw == ""
|
||||
else _number(entry, "bms_soc_floor", None)))
|
||||
return out
|
||||
|
||||
|
||||
def _unit_label(opts: dict, index: int) -> str:
|
||||
""""" at a single-inverter config, " (inverter-b)" at a roster.
|
||||
|
||||
@@ -871,28 +920,39 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
||||
# in-code mirror, pinned to config.yaml by test_peakguard.py, and main.py
|
||||
# reads the same one - exactly as maintenance.MAINT_OPTION_DEFAULTS now is
|
||||
# for the `maintenance_*` family.
|
||||
#
|
||||
# ⚠️ SAFETY-32 - GRADED ONCE PER UNIT, AND THE REFUSAL NAMES THE UNIT. One
|
||||
# `bms_soc_floor` for two packs compares the EMS floor against whichever
|
||||
# battery happened to be written into the flat key: a site with cut-outs of
|
||||
# 10 % and 30 % and `peak_soc_floor: 20` STARTED, and the guard would then
|
||||
# command a forced discharge that the second pack's BMS - not the operator's
|
||||
# floor - is the thing that stops. That is the disarmed-backstop state this
|
||||
# rule exists to refuse, reached through the rule itself. So the loop is over
|
||||
# units, and `_unit_label()` is fed the ROSTER index the value came off (see
|
||||
# `unit_bms_floors_indexed()`), because CFG-04 has just fixed the version of
|
||||
# this that named the wrong inverter.
|
||||
soc_floor = _number(opts, "peak_soc_floor",
|
||||
PEAK_OPTION_DEFAULTS["peak_soc_floor"])
|
||||
bms_floor = _number(opts, "bms_soc_floor",
|
||||
PEAK_OPTION_DEFAULTS["bms_soc_floor"])
|
||||
if soc_floor is None or bms_floor is None:
|
||||
problems.append(
|
||||
"peak_soc_floor and bms_soc_floor must both be numbers (got "
|
||||
f"{opts.get('peak_soc_floor')!r} / {opts.get('bms_soc_floor')!r})")
|
||||
elif soc_floor <= bms_floor:
|
||||
problems.append(
|
||||
f"peak_soc_floor is {soc_floor:.0f} % but the pack's own cut-out "
|
||||
f"(bms_soc_floor) is {bms_floor:.0f} %, so SAFETY-07's forced "
|
||||
"discharge has no EMS-side bound at all - THE BMS WINS, and it is "
|
||||
"the pack's protection rather than yours. The guard would report a "
|
||||
"SoC floor on its status page while being incapable of ever being "
|
||||
"the thing that stops the discharge, and the symptom of that is a "
|
||||
"battery repeatedly sitting at the BMS limit with no record of why "
|
||||
f"- which looks exactly like the SoC drift the maintenance cycle "
|
||||
f"exists to correct. Raise peak_soc_floor above {bms_floor:.0f} % "
|
||||
f"(the shipped default is "
|
||||
f"{PEAK_OPTION_DEFAULTS['peak_soc_floor']:.0f} %), or correct "
|
||||
"bms_soc_floor if it does not match this pack.")
|
||||
for _ix, _raw, bms_floor in unit_bms_floors_indexed(opts):
|
||||
where = _unit_label(opts, _ix)
|
||||
if soc_floor is None or bms_floor is None:
|
||||
problems.append(
|
||||
f"peak_soc_floor and bms_soc_floor{where} must both be numbers "
|
||||
f"(got {opts.get('peak_soc_floor')!r} / {_raw!r})")
|
||||
elif soc_floor <= bms_floor:
|
||||
problems.append(
|
||||
f"peak_soc_floor is {soc_floor:.0f} % but the pack's own cut-out "
|
||||
f"(bms_soc_floor{where}) is {bms_floor:.0f} %, so SAFETY-07's forced "
|
||||
"discharge has no EMS-side bound at all - THE BMS WINS, and it is "
|
||||
"the pack's protection rather than yours. The guard would report a "
|
||||
"SoC floor on its status page while being incapable of ever being "
|
||||
"the thing that stops the discharge, and the symptom of that is a "
|
||||
"battery repeatedly sitting at the BMS limit with no record of why "
|
||||
f"- which looks exactly like the SoC drift the maintenance cycle "
|
||||
f"exists to correct. Raise peak_soc_floor above {bms_floor:.0f} % "
|
||||
f"(the shipped default is "
|
||||
f"{PEAK_OPTION_DEFAULTS['peak_soc_floor']:.0f} %), or correct "
|
||||
f"bms_soc_floor{where} if it does not match this pack.")
|
||||
|
||||