diff --git a/goodwe_controller/test_safety84.py b/goodwe_controller/test_safety84.py index 47b0cdf..0b0c128 100644 --- a/goodwe_controller/test_safety84.py +++ b/goodwe_controller/test_safety84.py @@ -481,6 +481,10 @@ print("\n8. the N=1 and N=2 digests") # quarter's room, as at N=2, so the guard no longer steps in and discharges. # The banked quarters go 3461.9 -> 3450.0 W (aim 3450) and 3938.9 -> 3950.0 # W (aim 3950). n1_charge_dear (no cheap window) is unchanged. +# MAINT-28 re-pinned n2_charge_banked: in the 5000 W load (over the 3950 W +# aim) the maintenance charge no longer restarts at -125 W after each guard +# stop (t=1550 s, 64 of 480 rows); the pause is held until the load is gone +# (DECISIONS/MAINT-28-hold-the-pause-in-a-peak.md). The other five are equal. PINNED = { "n1_charge": "00f0a16b3ac1bd2830e9e0aaac8923fd9d1736c2bc6c543669bdd35b2fb542e9", @@ -493,7 +497,7 @@ PINNED = { "n2_charge_dear": "aa2bbc677a8e2274b25ba1170de1b1635e08a3bd93105e2a38a9bb1575b5b6db", "n2_charge_banked": - "a6973faea916e4c88ca1770047f94478346eeb1efa4889b154fad0747f91267f", + "5d523562219245c135a4e9aa856826bc2939a3157c6ae0320cafc2cd1a8a6cf1", } _now = s84.digests() for k in PINNED: