NOTES.md 5.10 measured the 1.78 kW step BOTH ways - "Up: ~18 s from step to deadband. Down: ~23 s" (NOTES.md:1550). SAFETY-39 takes 18 correctly: its bound is a REFUSAL and the looser number refuses less. This branch reused PLANT_SETTLE_S for the opposite job - how long the plant may still be the EXPLANATION for a divergence - where the conservative half is the longer one. ceil(23/2) = 12, not 9, and being short there does not refuse anything, it accuses. The false positive is real and is measured here. One inverter, one compute(), one plant, no second writer anywhere in the harness: the command falls through zero while the pack is still coasting the old way, unasked_power() calls our own power "unasked", the counter reaches 9 while it is still coasting, and the law emits "freeze-released". At the plant's own measured 18 s/23 s shape, over 272 load-step pairs, the 9-cycle bound fires in 62 and the 12-cycle bound in 2. PLANT_SETTLE_DOWN_S = 23.0 is added beside PLANT_SETTLE_S = 18.0, because the plant's settling time is a PAIR and each bound has to say which half it means and why. SETTLE_CYCLES = ceil(PLANT_SETTLE_DOWN_S / LOOP_TICK_S) = 12. It is no longer the reciprocal of SLEW_RAIL_FRAC; that was a coincidence of both reading the same half, and test_control.py now asserts the inequality. _SAT_COUNT_CAP moves with it, 10 -> 13. config.yaml accepts saturation_cycles as int(1,10), so the whole accepted range is now strictly BELOW the bound and the degenerate configuration this branch used to document no longer exists - pinned against config.yaml's own schema line. Three shipped statements were falsified by that measurement and are rewritten, not renumbered - at 12 the residual is smaller, not zero: unasked_power()'s docstring said anything outside the interval "was put there by something other than this loop". It was our own power: eight cycles after a +1990 W command the command is 0 and the pack still reads +522.3 W. control.py said "SO THE BOUND BELONGS TO (b) AND ONLY TO (b)". It fired in case (a). DOCS.md told an operator "if you see freeze-released, look for the second writer" - on a single-inverter install, hunting something that does not exist. Replaced by a section that gives the innocent causes first (a large load or PV swing; a plant slower than the one measured, 8/320 scenarios at 23 s rising to 268/320 at 50 s) and the second writer only when the state STANDS. Round 1's own results are kept and re-graded, not weakened. The release/1.0 sweep had to widen to reach the new bound (3780 cases): 3267 bit-identical, 432 releases, 27 command changes - all still charge starts from prev_w == 0 - and 81 differing in the saturation counter alone, which nothing downstream can read. The card's case releases on the twelfth saturated cycle instead of the ninth and settles at the same -1190 W against the same frozen integrator. Also corrected, because they were claims and did not reproduce: the coverage table's "output freeze" row was 11, and the mutation form its own note describes gives 6 on this tree, 6 on the first SAFETY-13 commit and 2 on release/1.0; the detector row was left at 11 and is 15; the frozen = False footnote was left at 10 and is 13. And section 6 reported 107 625 as "released states" when it is the number of states SWEPT - 67 500 of them release, and both are counted now. Nothing here reached the inverter. 22/22 test files pass in goodwe-addon-ci, tree rsynced to a plain path, mounted :ro, python3 -B, __pycache__ purged and printed first (0 dirs / 0 .pyc; the worktree carries none). Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
co-authored by
Claude Opus 5
parent
6c4565659b
commit
f156fadac0
+58
-17
@@ -473,7 +473,7 @@ behind it would trip the firmware watchdog on a system that is working fine.
|
||||
| `target_grid_w` | -10 | What the meter should rest at. Negative = a slight export |
|
||||
| `step_w` | 10 | Quantisation |
|
||||
| `saturation_w` | 500 | Divergence that counts as "the inverter is at a limit" |
|
||||
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. A cycle is one meter update or `cycle_floor_s`, whichever comes first - see the note below. **Do not set to 1**, and **do not set it to 9 or 10** either: at 9 the freeze cannot engage before its own exit is due, so the no-start block stops existing (SAFETY-13, below) |
|
||||
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. A cycle is one meter update or `cycle_floor_s`, whichever comes first - see the note below. **Do not set to 1**. Every value this file accepts (1-10) is below the freeze's own release bound of 12 cycles, so no accepted setting can stop the block engaging - see SAFETY-13, below |
|
||||
| `integrator_max_w` | 0 | Bound on the loop's accumulator, and 0 means "same as `max_w`". Caps how much stale error can be waiting to unwind when the sign flips. **Do not raise it above `max_w`** - the output clamp already bounds what is commanded, so the only thing extra headroom buys is more cycles of wrong-direction power after every saturation event. Lowering it below `max_w` is the useful direction |
|
||||
| `heartbeat_s` | 10 | Refresh interval; must stay well under the firmware watchdog |
|
||||
| `cycle_floor_s` | 15 | The longest the loop may go without evaluating. A deadline on the gap between cycles, reset by every cycle — on a healthy meter it never elapses and changes nothing. Raise it only if your meter is slower than ~10 s; it must stay under `meter_max_age_s`, past which there is no reading to evaluate anyway |
|
||||
@@ -645,35 +645,76 @@ one is the decision:
|
||||
| the inverter is… | can it clear itself? | what happens now |
|
||||
|---|---|---|
|
||||
| doing **less** than the command, in the command's own direction — a cold pack, a curtailment, an export cap | **yes.** The command is pinned at something the inverter can reach, so it catches up and the freeze clears | unchanged: frozen for as long as it lasts, with no exit |
|
||||
| doing something **outside** what the command can explain — overshooting it, or the opposite sign | **no.** Clearing the freeze needs the inverter to track *our* command, and the other writer is what stops it | the freeze releases once the divergence has outlasted the plant that could otherwise have explained it |
|
||||
| doing something **outside** what the command can explain — overshooting it, or the opposite sign | **not necessarily.** If another writer is on the actuator, clearing the freeze needs the inverter to track *our* command and the other writer is what stops it, so nothing ends it | the freeze releases once the divergence has outlasted the plant that could otherwise have explained it — see *what `freeze-released` actually tells you*, below, because this row is also where our own ramp lands |
|
||||
|
||||
The second row's threshold is not a new number. `PLANT_SETTLE_S` (18 s, measured) is how
|
||||
long this plant takes to settle, so a divergence still standing after that is not this
|
||||
plant catching up; at the measured 2 s meter tick that is **9 cycles**, which is the
|
||||
same relationship the slew limit already uses (`control.py`, `SETTLE_CYCLES`).
|
||||
The second row's threshold is the plant's own measured settling time — **the slower of
|
||||
the two directions it was measured in.** The 2026-08-22 step test timed the same 1.78 kW
|
||||
step both ways: about 18 s to settle going up, about 23 s coming back down. 23 s is the
|
||||
one that belongs here, because the question this bound answers is *how long may the plant
|
||||
still be the explanation*, and the safe answer is to keep believing the plant for as long
|
||||
as the plant has ever been seen to take. At the measured 2 s meter tick that is
|
||||
**12 cycles** (`control.py`, `SETTLE_CYCLES`).
|
||||
|
||||
⚠️ **The first version of this feature used 18 s, and 9 cycles was wrong in the direction
|
||||
that accuses.** Nine cycles is three short of the plant's own down-ramp, so an ordinary
|
||||
load step on a **single** inverter — the command falling through zero while the pack is
|
||||
still coasting the old way — could produce `freeze-released` with nothing else on the bus
|
||||
at all. Driven in the container against a model of the measured plant, one inverter and
|
||||
no second writer anywhere: over 272 load-step pairs the 9-cycle bound produced a release
|
||||
in 62 of them and the shipped 12-cycle bound in 2.
|
||||
|
||||
**Releasing the output freeze does not unfreeze the loop.** The *integrator* freeze is
|
||||
untouched, so the command is free to move only as far as an accumulator that stopped
|
||||
accumulating cycles ago, one slew step per cycle. Measured on the simulator at the live
|
||||
install's shape (`max_w 5000`, `slew_w 400`, `target_grid_w -10`), with another writer
|
||||
holding the pack at +700 W and 2 kW of export standing: the command holds at 0 W while
|
||||
the counter climbs, starts at the ninth saturated cycle, and settles at **−1190 W**
|
||||
against a frozen integrator of −1194 W — not at the 5000 W rail. Before this change the
|
||||
same run held 0.0 W on every cycle, for as long as the other writer stayed.
|
||||
the counter climbs, starts on the **twelfth** saturated cycle, walks 0 → −400 → −800, and
|
||||
settles at **−1190 W** against a frozen integrator of −1194 W — not at the 5000 W rail.
|
||||
Before this change the same run held 0.0 W on every cycle, for as long as the other
|
||||
writer stayed.
|
||||
|
||||
⚠️ **The site still does not reach its target in that state, and it is not supposed
|
||||
to.** What the exit buys is that the battery stops being idle while the site exports;
|
||||
what it does not buy is correct regulation against an actuator somebody else is also
|
||||
writing to. A standing grid error with another writer on the bus is the symptom of a
|
||||
configuration this add-on refuses to support, not a tuning problem. If you see
|
||||
`freeze-released` in the action log, look for the second writer.
|
||||
configuration this add-on refuses to support, not a tuning problem.
|
||||
|
||||
⚠️ **One configuration removes the block entirely, silently.** `saturation_cycles` is
|
||||
accepted up to 10. Set it at or above 9 and the freeze does not engage until the bound
|
||||
has already passed, so the no-start block never happens at all. This is not refused at
|
||||
startup — a controller that will not boot over a tuning nuance is worse than the nuance
|
||||
— but it is why the default is 3 and why the table above says **do not set to 1** at one
|
||||
end and leaves you this note at the other.
|
||||
#### What `freeze-released` in the action log actually tells you
|
||||
|
||||
**It says: the inverter's power did not match the command for longer than this plant has
|
||||
ever been measured to take to settle.** That is all it says. It is a reason to go
|
||||
looking; it is not a finding, and in particular it is **not** proof that a second writer
|
||||
exists.
|
||||
|
||||
The test behind it compares the reading against **one cycle's** command, and the pack
|
||||
carries more than one cycle of history. So our own power, arriving late, can look like
|
||||
somebody else's:
|
||||
|
||||
- **A big, fast load step is the ordinary innocent cause.** The command falls through
|
||||
zero while the pack is still coasting in the old direction, and for a few cycles the
|
||||
reading has the sign the command *used* to have. Measured, one inverter, nothing else
|
||||
on the bus: eight cycles after a +1990 W command the command was 0 and the pack still
|
||||
read +522.3 W.
|
||||
- **A plant slower than the one that was measured does it too.** The 12-cycle bound is
|
||||
derived from a 23 s down-ramp. A colder or larger pack that takes longer than that will
|
||||
produce releases on its own, and no constant read off the 2026-08-22 measurement can
|
||||
prevent it. In the same container sweep, holding the bound at 12 and lengthening only
|
||||
the plant's down-ramp, single-inverter releases went from 8 of 320 scenarios at the
|
||||
measured 23 s to 59 of 320 at 34 s and 268 of 320 at 50 s.
|
||||
|
||||
**So, in order:** if you see `freeze-released` **once, during or just after a large load
|
||||
or PV swing**, that is most likely the loop's own ramp and needs nothing. If you see it
|
||||
**standing** — cycle after cycle, at a steady load, with a standing grid error the
|
||||
battery is not correcting — then look for the second writer: another controller, a
|
||||
scheduler in the inverter's own app, or an installer tool left connected. That is the
|
||||
configuration §1.5 of the specification rules out, and it is the one this exit exists to
|
||||
stop the loop stalling on forever.
|
||||
|
||||
⚠️ **No `saturation_cycles` you can set removes the block.** This file accepts 1-10, and
|
||||
all of those are below the 12-cycle release bound, so the freeze always engages before
|
||||
its own exit is due. (The first version of this feature had the bound at 9, where a
|
||||
setting of 9 or 10 *did* silently delete the block; moving the bound to 12 closed that
|
||||
by construction rather than by warning about it.)
|
||||
|
||||
#### Why `target_grid_w` is not zero
|
||||
|
||||
|
||||
Reference in New Issue
Block a user