@@ -8,16 +8,17 @@ options). Options that start 0.13.0 also start 0.14.0. With one inverter,
|
||||
control is the same as in 0.13.0.
|
||||
|
||||
⭐ **Two inverters are now supported** for the monthly maintenance (drain,
|
||||
charge, hold) and the peak guard. To add the second inverter, follow Stage 5
|
||||
of `docs/commissioning-b.md` in the `admin/goodwe` repo. Read the known
|
||||
issues below first: four of them are about two inverters.
|
||||
charge, hold) and the peak guard. To add a second inverter, follow
|
||||
`docs/commissioning-b.md` in the `admin/goodwe` repo. Its Stage 5, where the
|
||||
add-on takes control of it, needs 0.14.0. Read the known issues below first:
|
||||
three of them are about two inverters.
|
||||
|
||||
Contents of this release, in merge order since 0.13.0 (`8c438ab`):
|
||||
|
||||
| | |
|
||||
|---|---|
|
||||
| `f3e409c` | Two batteries: one at or under its peak reserve gives last, after the others give their full power. It is freed again above reserve + 1 point (e.g. at 22 % for a 20 % reserve). At a quarter's edge the peak guard no longer drops out for a second ([[SAFETY-91]]) |
|
||||
| `858f77c` | Two batteries: when a maintenance charge ends, for any reason, the other battery no longer starts charging from the grid; control hands over in 400 W steps ([[SAFETY-93]]) |
|
||||
| `f3e409c` | Two inverters: a battery at or under its peak reserve gives last, after the others give their full power. It is freed again above reserve + 1 point (e.g. above 21 % for a 20 % reserve). At a quarter's edge the peak guard no longer drops out for a second ([[SAFETY-91]]) |
|
||||
| `858f77c` | Two inverters: when a maintenance charge ends, for any reason, the other battery no longer starts charging from the grid; control hands over in small steps ([[SAFETY-93]]) |
|
||||
| `e51e3e0` | CI tests against a newer `admin/goodwe` (CI only) ([[CI-13]]) |
|
||||
|
||||
### Known issues
|
||||
@@ -25,7 +26,7 @@ Contents of this release, in merge order since 0.13.0 (`8c438ab`):
|
||||
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
|
||||
- A healthy battery that turns from charging to giving can be held at 0 W for up to 15 min ([[SAFETY-94]]).
|
||||
- After a gap in the P1 meter, the peak guard is blind for the rest of that quarter hour ([[SAFETY-90]]).
|
||||
- Two inverters: if one battery's drain stops early (e.g. switched Off), the other can briefly export up to about 1.6 kW ([[SAFETY-95]]).
|
||||
- Two inverters: if one battery's drain stops early (e.g. switched Off), the other battery can jump to about 1.6 kW at once, and the surplus goes to the grid ([[SAFETY-95]]).
|
||||
- Two inverters: after one battery's link drops, control can stall until a safety stop ([[SAFETY-96]]).
|
||||
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
|
||||
|
||||
|
||||