PKG-16: cut 0.10.1, so SAFETY-57's fix can reach an installed 0.10.0
checks / unit (pull_request) Successful in 8m0s
checks / unit (pull_request) Successful in 8m0s
The Supervisor decides an update exists by comparing config.yaml's version string with the one the box reports. master and release/1.0 both said 0.10.0, so SAFETY-57 - a deadlock that parked the reference battery for ~13 min on 2026-09-21 while the house exported 2.4 kW - had no way of reaching the box that has it. A patch bump is the delivery mechanism, not bookkeeping. - config.yaml: 0.10.0 -> 0.10.1. Nothing else in the option surface moves: no key added or removed, no default changed, no enum widened, no rule added to validate.py, so a blob that starts on 0.10.0 starts on 0.10.1. - CHANGELOG.md: a new `## 0.10.1` section, holding SAFETY-57's entry moved out of `## 0.10.0`. The entry opened by saying it was misfiled and that whoever cut the next version owned moving it; this is that cut, so that paragraph is replaced by what an operator actually needs in order to decide - what the deadlock does (command parked at 0 W, batt reading gated to MISSING, escape condition unreachable from inside the state), how to recognise it (setpoint stuck at exactly 0 W with the battery register flat, a STALE line and no clearing line) and that a restart of the add-on clears it. - PKG-16 proper: `## 0.10.0`'s preamble still claimed 0.10.0 "has never been built or pulled anywhere" and that the reference install was on 0.7.0. Both stopped being true on 2026-09-20 ~22:18 CEST, when 0.10.0 was installed as a repository add-on (slug 68285ac7_goodwe_controller) and began regulating a real battery. The section's own bump argument was explicitly conditional on that; the condition has fired, so the argument is retold as history and the section is closed. This text is what the Supervisor shows beside Update. Also fixes, in this file only, the three non-blocking documentation defects raised on PR #104 - issuecomments 1445, 1446 and 1447: - 1446: the live episode is 790 s, not 710 s. Re-derived rather than rescaled: at >= 790 s the committed 16-day replay gives 16 of 93, not 17. - 1447: the BMS keep-alive pulse was an inference stated as a measurement. No committed capture identifies one, and on this episode 0x0518 never moved at all. The measured claim replaces the firmware story. - 1445: "neither consumer can reach a verdict inside one window" is universal as written and graded on a fixture that puts the obligation back on every release. It now carries the qualifier the reviewer asked for, and names the unbounded case and why the shipped one-inverter roster cannot reach it. The same three defects also sit in app/freshness.py, test_freshness.py, DOCS.md and the DECISIONS note. They are deliberately NOT touched here: this PR is config.yaml and CHANGELOG.md only, and none of them is worth delaying a live safety fix. SAFETY-56 and SAFETY-58 are likewise untouched. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
co-authored by
Claude Opus 5
parent
b9f7bd0506
commit
eb88646899
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.10.0"
|
||||
version: "0.10.1"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
|
||||
Reference in New Issue
Block a user