MAINT-13 review: tests for a stale charge record and a clock step back; DOCS names the 7 day end
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -1672,7 +1672,8 @@ balances, so it need not reach `maintenance_soc_target`. The charge counts as
|
|||||||
done when the battery is within 3 points of the target and has taken no more
|
done when the battery is within 3 points of the target and has taken no more
|
||||||
charge for 60 minutes of charging time, or when the charging time (36 hours) runs
|
charge for 60 minutes of charging time, or when the charging time (36 hours) runs
|
||||||
out within 3 points of the target. Only the minutes the cheap-hours gate let the
|
out within 3 points of the target. Only the minutes the cheap-hours gate let the
|
||||||
battery charge count. Then the usual hold follows.
|
battery charge count, and the charge ends after 7 days at the
|
||||||
|
latest. Then the usual hold follows.
|
||||||
|
|
||||||
**When a cycle fails.** If the battery does not empty in 12 hours, or does not
|
**When a cycle fails.** If the battery does not empty in 12 hours, or does not
|
||||||
get within 3 points of the target in 36 hours of charging time, the cycle
|
get within 3 points of the target in 36 hours of charging time, the cycle
|
||||||
|
|||||||
@@ -240,6 +240,10 @@ check("a gap in the ticks (add-on down) counts for exactly 5 minutes (the cap)",
|
|||||||
abs(m._trk["open_min"] - before - 5.0) < 1e-9)
|
abs(m._trk["open_min"] - before - 5.0) < 1e-9)
|
||||||
m.tick(t + 2 * timedelta(hours=1) + 2 * MIN, 70.0)
|
m.tick(t + 2 * timedelta(hours=1) + 2 * MIN, 70.0)
|
||||||
check("...and a 2 minute step counts 2", abs(m._trk["open_min"] - before - 7.0) < 1e-9)
|
check("...and a 2 minute step counts 2", abs(m._trk["open_min"] - before - 7.0) < 1e-9)
|
||||||
|
_t = t + 2 * timedelta(hours=1) + 2 * MIN
|
||||||
|
m.tick(_t - 10 * MIN, 70.0) # the clock steps back 10 min
|
||||||
|
check("...and a step back in time counts nothing (not minus)",
|
||||||
|
abs(m._trk["open_min"] - before - 7.0) < 1e-9)
|
||||||
|
|
||||||
print("6. restarts and old state files")
|
print("6. restarts and old state files")
|
||||||
with tempfile.TemporaryDirectory() as d:
|
with tempfile.TemporaryDirectory() as d:
|
||||||
@@ -286,6 +290,19 @@ with tempfile.TemporaryDirectory() as d:
|
|||||||
res, _, out = run(mo, T0 + MIN, 120, 70.0)
|
res, _, out = run(mo, T0 + MIN, 120, 70.0)
|
||||||
check("...so it fails when the 36 h are up, as before",
|
check("...so it fails when the 36 h are up, as before",
|
||||||
out and out[0].failed == "charge")
|
out and out[0].failed == "charge")
|
||||||
|
# A record left by another charge (an add-on rolled back and forward
|
||||||
|
# again does not clear it) must not be read as this charge's.
|
||||||
|
stale = {"phase": "charge",
|
||||||
|
"phase_started": (T0 - timedelta(hours=2)).isoformat(),
|
||||||
|
"charge_track": {"since": (T0 - timedelta(days=30)).isoformat(),
|
||||||
|
"open_min": 2000.0, "flat_min": 59.0,
|
||||||
|
"best": 99.0, "at": None}}
|
||||||
|
ms = Maintenance(CFG, Mem(stale))
|
||||||
|
r = ms.tick(T0, 98.0)
|
||||||
|
check("a charge record from another charge is ignored: this charge counts "
|
||||||
|
"its own 2 h and its own best",
|
||||||
|
r.phase == CHARGE and 119 < ms._trk["open_min"] < 121
|
||||||
|
and ms._trk["flat_min"] == 0.0 and ms._trk["best"] == 98.0)
|
||||||
mi = Maintenance(CFG, Store(os.path.join(d, "none.json")))
|
mi = Maintenance(CFG, Store(os.path.join(d, "none.json")))
|
||||||
check("no state file: due, no back-off", mi.due(T0) and mi.backoff_until(T0) is None)
|
check("no state file: due, no back-off", mi.due(T0) and mi.backoff_until(T0) is None)
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue