SAFETY-24: an energy floor under the peak guard's forced discharge
checks / unit (pull_request) Successful in 3m29s
checks / unit (pull_request) Successful in 3m29s
SAFETY-07 can command a discharge to hold a billed quarter down, and nothing below it consulted the state of charge. On the 2026-08-20 replay it asks for 878 Wh in a day. Relying on the BMS is not absurd - it is a real floor and it works - but it is the pack's protection rather than the operator's, and a month of aggressive quarters leaves the battery repeatedly at that cut-out with no EMS-side record of why. The first symptom is a pack never available when wanted, which is indistinguishable from the SoC drift MAINT-01 exists to correct. decide() now takes soc and soc_floor, both required and neither defaulted, and discharge_permitted() is the one place the question is answered. Above the floor nothing changes. At or below it the guard files a 0 W floor instead of a sized one - one-directional, so charging stays blocked and no discharge is capped - and reports floor_limited with the reason it bound. It is not a trip: every stop in 11.2's table still outranks the claim, and the floor is never negative, so 9.1's asymmetry survives as a property of the object (0 negative floors over 1296 swept combinations, SoC included). The SoC is graded only after `wanted > 0` is established, so it is never evaluated where it governs nothing. An unreadable SoC is floor-limited, not a full battery - a full battery is exactly the value that would disarm the floor, and this project shipped that defaulting once already. Failing to shave is not silent: one notification per episode (goodwe_peak_soc_floor), distinct from the saturation alarm because the two ask for opposite operator actions, plus its own status row and an action-log line. Verified by replay. The 2026-08-20 capture is driven against a modelled pack sized from the day's own measured appetite, so it genuinely exhausts: without the floor it reaches the BMS cut-out and holds there for 1227 guard cycles; with it the pack stops at 20.0 % and never touches the BMS. The energy withheld equals the energy between the two floors to within one cycle at the rail. The honest half is reported too - the worst quarter goes 4338 W -> 5030 W, because a floor-limited guard shaves less on purpose. Two new options, mirrored once in peakguard.PEAK_OPTION_DEFAULTS (TARIFF-02's pattern), imported by validate.py and main.py rather than typed as literals and pinned to config.yaml by a check that reads the file - so CFG-03 still tracks three places. validate.py rule 8 refuses peak_soc_floor <= bms_soc_floor at startup, in CFG-01/MAINT-04's manner. maintenance_soc_floor is deliberately not reused and not renamed: it is a drain target, not a spend limit, and the rename is recorded as a decision to revisit if a third floor appears. Eleven mutations of the shipped source were run against the checks; all eleven go red and there are no survivors. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
This commit is contained in:
co-authored by
Claude Opus 5
parent
e7c95bfd8a
commit
e709554857
@@ -246,19 +246,100 @@ validate.py are untouched by this ticket, exactly as TARIFF-01 left them, and
|
||||
mismatch trap 14's own warning box describes.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
⚠️ WHAT THIS GUARD DOES NOT HAVE: AN ENERGY BACKSTOP. SEE SAFETY-24.
|
||||
SAFETY-24: THE ENERGY BACKSTOP THIS GUARD SHIPPED WITHOUT
|
||||
|
||||
The graded branch can FORCE DISCHARGE, and nothing in this file or in the loop
|
||||
below it consults the state of charge - `soc_floor` belongs to the maintenance
|
||||
cycle, and freeze.py already records that for the grid-following loop "the BMS
|
||||
is the sole energy backstop". On the 2026-08-20 replay the guard asks for 878 Wh
|
||||
in a day. Against a pack sitting near 9 % that is not nothing, and the guard will
|
||||
keep asking as long as the meter says the quarter is over the ceiling.
|
||||
SAFETY-07 left this file saying, in its own words, that the graded branch can
|
||||
FORCE DISCHARGE and that nothing below it consults the state of charge - "the
|
||||
BMS is the sole energy backstop" (freeze.py). On the 2026-08-20 replay the guard
|
||||
asks for 878 Wh in a day, and it keeps asking for as long as the meter says the
|
||||
quarter is over the ceiling. That is the behaviour working as designed, and it
|
||||
is unbounded from below by anything in the EMS.
|
||||
|
||||
That is deliberate for THIS card and it is filed as SAFETY-24. It is also the
|
||||
reason this must not go to a client install before SAFETY-24 lands: on the
|
||||
reference site the BMS is a known quantity and an operator is present, and on a
|
||||
client site neither is true.
|
||||
⚠️ STATE THE RISK FAIRLY, because overstating it is how a real one gets ignored.
|
||||
Relying on the BMS is not absurd: it is a genuine floor and it works. But it is
|
||||
THE PACK's protection, not the OPERATOR's. A month of aggressive quarters can
|
||||
leave the battery repeatedly parked at that floor with no EMS-side record of
|
||||
why, and the first symptom - a pack that is never available when it is wanted -
|
||||
is indistinguishable from the SoC drift MAINT-01 exists to correct.
|
||||
|
||||
So `decide()` now takes `soc` and `soc_floor`, and `discharge_permitted()` is
|
||||
the one place the question is answered. Four things about the shape of it:
|
||||
|
||||
1. IT IS NOT A TRIP, AND IT MUST NOT BECOME ONE. SAFETY-07's claim is a LIMIT
|
||||
and every stop in 11.2's table still outranks it. This floor is about
|
||||
ENERGY - how far down the guard may spend the pack for money - not about
|
||||
last-resort safety. The action when it binds is therefore to stop ASKING
|
||||
for more discharge, not to command anything.
|
||||
|
||||
2. THE ACTION IS `floor_w = 0.0`, WHICH IS THE BLIND BRANCH'S ACTION FOR THE
|
||||
BLIND BRANCH'S REASON. Zero is one-directional: it forbids CHARGING, which
|
||||
can only ever lower delivered offtake, and it forbids nothing else. It
|
||||
cannot pull the loop off a discharge it is already doing, because a `lo`
|
||||
limit structurally cannot cap discharge - the property this module's whole
|
||||
shape rests on, and one a NEGATIVE floor would destroy. Nothing here can
|
||||
produce a negative floor: the only two values `floor_w` ever takes are 0.0
|
||||
and `min(wanted, achievable)` with `wanted > 0` already established.
|
||||
|
||||
⚠️ AND IT DOES NOT BOUND THE LOOP. Self-consumption may still drain the
|
||||
pack past this floor, exactly as SAFETY-18 recorded. That is not fixed
|
||||
here and must not be claimed: this card bounds THE PEAK GUARD's OWN forced
|
||||
discharge, which is the thing SAFETY-07 introduced. A loop-side SoC guard
|
||||
is a different lever with a different right value.
|
||||
|
||||
3. IT IS GRADED ONLY WHERE IT IS NOT DEGENERATE. The SoC question is asked
|
||||
AFTER `wanted > 0` is established - i.e. only where a forced discharge is
|
||||
actually being asked for. Asked earlier it would grade a quantity that
|
||||
governs nothing, and would report "floor-limited" on a quiet afternoon
|
||||
where the guard was never going to discharge anyway.
|
||||
|
||||
4. AN UNREADABLE SoC IS NOT A FULL BATTERY. `soc=None` is floor-limited, not
|
||||
permitted. This is `PeakReading`'s lesson in the one place it bites
|
||||
hardest: a full battery is exactly the value that would disarm this floor,
|
||||
so a failed read defaulting to one would silently restore the unbounded
|
||||
discharge this card exists to remove. Both new arguments are REQUIRED
|
||||
keyword-only and neither has a default, which is TEST-14 read as a rule
|
||||
rather than as a story: a required field that gains a default is how three
|
||||
separate files in this repo shipped a quiet fallback.
|
||||
|
||||
AND FAILING TO SHAVE MUST NOT BE SILENT. The whole point of the guard is the
|
||||
euro figure, so a floor-limited cycle carries `floor_limited=True` and main.py
|
||||
raises ONE notification on the edge, saying the quarter will be exceeded - the
|
||||
same shape, and the same argument, as `saturated`. The two are mutually
|
||||
exclusive by construction: a floor-limited decision asks for nothing, so it
|
||||
cannot have run out of inverter.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
CFG-03: TWO NEW OPTIONS, MIRRORED ONCE, AND WHY BOTH ARE NEEDED
|
||||
|
||||
SAFETY-07 added none and said so. This card cannot: an EMS-side floor is a
|
||||
number only the site knows, and refusing one set below the pack's own cut-out
|
||||
means knowing that cut-out too.
|
||||
|
||||
* `peak_soc_floor` - the EMS floor. ⚠️ NOT `maintenance_soc_floor`. That is
|
||||
the maintenance cycle's DRAIN TARGET: the depth a monthly recalibration
|
||||
deliberately goes to, once, under supervision. This is the depth a
|
||||
money-saving discharge may never reach, on any day of the month. Sharing
|
||||
one key would couple two features whose right values differ and would widen
|
||||
CFG-03 rather than narrow it.
|
||||
* `bms_soc_floor` - the pack's own cut-out (register 0x0560 on the reference
|
||||
unit, 10 %). It is here so validate.py rule 8 can REFUSE a `peak_soc_floor`
|
||||
at or below it. That configuration is CFG-01 rule (a): the operator states
|
||||
a floor, the BMS enforces a different one, and the status page reports an
|
||||
energy backstop that can never bind.
|
||||
|
||||
Both defaults are mirrored ONCE, in `PEAK_OPTION_DEFAULTS` below, which is
|
||||
TARIFF-02's `PRICE_OPTION_DEFAULTS` pattern - imported by validate.py and by
|
||||
main.py, pinned to config.yaml by test_peakguard.py rather than transcribed.
|
||||
This module still reads no option itself: `decide()` takes both as ARGUMENTS,
|
||||
makes no `.get()` call, and the mirror is a default table, not a read.
|
||||
|
||||
⚠️ A DECISION RECORDED, NOT A RENAME DONE. Now that a second SoC floor exists,
|
||||
`maintenance_soc_floor` is the ambiguous name of the two - it reads like "the
|
||||
SoC floor" and is not. Renaming it is an option migration on a live install for
|
||||
a clarity gain, so the decision recorded here is: KEEP IT, and carry the
|
||||
distinction in DOCS.md and in this comment. Revisit if a THIRD floor appears -
|
||||
a loop-side guard would be the third - at which point the migration buys enough
|
||||
to be worth its cost.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
AND IT READS NO PER-PHASE QUANTITY, ON PURPOSE
|
||||
@@ -287,8 +368,44 @@ BLIND_FROZEN = "SAFETY-18: the meter is answering without changing"
|
||||
CEILING_CAP = "peak_cap_w"
|
||||
CEILING_MONTH_PEAK = "the month's banked peak"
|
||||
|
||||
# SAFETY-24. Why the forced discharge may not be sized. Reasons, not booleans,
|
||||
# for BLIND_*'s reason: the status page, the action log and the operator
|
||||
# notification all have to say WHICH, and "floor-limited" alone is unactionable.
|
||||
FLOOR_SOC_UNREADABLE = ("the battery state of charge was not measured this "
|
||||
"cycle, and an unreadable SoC is not a full battery")
|
||||
FLOOR_AT_SOC_FLOOR = "state of charge is at or below the peak guard's SoC floor"
|
||||
|
||||
SOURCE = "peak"
|
||||
|
||||
# ⚠️ CFG-03. THE ONE IN-CODE MIRROR OF config.yaml FOR THIS CARD'S OPTIONS, and
|
||||
# it is TARIFF-02's `PRICE_OPTION_DEFAULTS` pattern for TARIFF-02's reason: the
|
||||
# add-on already carries option defaults in three places (config.yaml's
|
||||
# `options:`, config.yaml's `schema:`, and main.py's literal `.get()`
|
||||
# fallbacks), and a fourth is the open ticket. validate.py and main.py both
|
||||
# import THIS dict rather than typing a literal, and test_peakguard.py pins it
|
||||
# to config.yaml by READING the file - so a drift goes red instead of shipping.
|
||||
#
|
||||
# ⚠️ NOT A READ. `decide()` takes both values as arguments and this module makes
|
||||
# no `.get()` call at all; the dict is a default table for its two callers.
|
||||
PEAK_OPTION_DEFAULTS = {
|
||||
# The EMS-side floor on SAFETY-07's forced discharge, in percent.
|
||||
#
|
||||
# 20 is DERIVED from the two numbers this repository already has, not
|
||||
# chosen. The reference pack is 300 Ah at 51.2 V with DoD 90 - 13.8 kWh
|
||||
# usable, the figure validate.py's rule 6 note already quotes - and the
|
||||
# 2026-08-20 replay models 878 Wh of guard discharge in a day, which is
|
||||
# 6.4 % of that. A floor 10 points above the pack's own 10 % cut-out
|
||||
# therefore leaves the guard roughly 1.6 of its worst observed days of room
|
||||
# before it stops, which is the smallest margin that lets the guard do its
|
||||
# job on a bad day and still never reach the BMS.
|
||||
"peak_soc_floor": 20,
|
||||
# The pack's OWN cut-out, in percent: what the BMS enforces regardless of
|
||||
# anything here. On the reference unit this is register 0x0560, read as 10,
|
||||
# and it is consistent with DoD 90 on a full pack. It exists so validate.py
|
||||
# rule 8 can refuse a `peak_soc_floor` at or below it - see that rule.
|
||||
"bms_soc_floor": 10,
|
||||
}
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class PeakDecision:
|
||||
@@ -309,9 +426,19 @@ class PeakDecision:
|
||||
excess_w: float = 0.0
|
||||
wanted_w: float | None = None # the floor before `achievable_w` clamped it
|
||||
saturated: bool = False
|
||||
# SAFETY-24. True when a forced discharge WAS wanted and the EMS-side SoC
|
||||
# floor refused to size it. Mutually exclusive with `saturated` by
|
||||
# construction: this branch asks for nothing, so it cannot have run out of
|
||||
# inverter. `soc_floor_reason` says WHICH of the two ways it bound.
|
||||
floor_limited: bool = False
|
||||
soc: float | None = None
|
||||
soc_floor: float | None = None
|
||||
soc_floor_reason: str | None = None
|
||||
reason: str = ""
|
||||
|
||||
def explain(self) -> str:
|
||||
if self.floor_limited:
|
||||
return self.reason
|
||||
if not self.engaged:
|
||||
if self.projected_w is None:
|
||||
return f"peak guard idle - {self.reason}"
|
||||
@@ -383,7 +510,44 @@ def blindness(projection, max_hold_s, frozen: bool) -> str | None:
|
||||
return None
|
||||
|
||||
|
||||
def decide(projection, *, batt_w, cap_w, reading, achievable_w,
|
||||
def discharge_permitted(soc, soc_floor) -> str | None:
|
||||
"""SAFETY-24. May the guard size a forced discharge, or why may it not?
|
||||
|
||||
Returns None when it may, and otherwise the REASON it may not - which the
|
||||
decision, the status page, the action log and the operator notification all
|
||||
carry, because "floor-limited" on its own tells nobody what to do.
|
||||
|
||||
THE ONE PLACE THIS QUESTION IS ANSWERED, and it is public for the reason
|
||||
`freeze.looks_frozen()`, `watchdog.loop_is_following()` and
|
||||
`shaping_suspended()` are: a safety predicate transcribed into its own check
|
||||
is one copy plus a future disagreement about what the check means, and the
|
||||
copy that drifts is always the grading one.
|
||||
|
||||
⚠️ `soc is None` IS NOT PERMISSION. A failed read is not an observation, and
|
||||
a FULL BATTERY is exactly the value that would disarm this floor - so a
|
||||
`float(soc or 100)` here would restore the unbounded discharge this card
|
||||
removes, silently, on the one install whose SoC sensor is misnamed. There is
|
||||
deliberately no default argument on either parameter.
|
||||
|
||||
⚠️ AND `soc_floor is None` IS NOT PERMISSION EITHER, for the same reason one
|
||||
step further out: a caller that has no floor configured has not thereby been
|
||||
granted an unbounded one.
|
||||
|
||||
Boundary: `<=`, not `<`. A pack sitting exactly ON the floor has already
|
||||
spent everything this guard was allowed to spend; permitting one more cycle
|
||||
there would make the floor mean "one cycle below the floor".
|
||||
"""
|
||||
if soc is None:
|
||||
return FLOOR_SOC_UNREADABLE
|
||||
if soc_floor is None:
|
||||
return ("no peak guard SoC floor is configured, so there is nothing to "
|
||||
"bound a forced discharge with")
|
||||
if float(soc) <= float(soc_floor):
|
||||
return FLOOR_AT_SOC_FLOOR
|
||||
return None
|
||||
|
||||
|
||||
def decide(projection, *, batt_w, cap_w, reading, achievable_w, soc, soc_floor,
|
||||
max_hold_s=None, frozen: bool = False) -> PeakDecision:
|
||||
"""The whole guard. Pure: no clock, no I/O, no state carried between calls.
|
||||
|
||||
@@ -395,6 +559,13 @@ def decide(projection, *, batt_w, cap_w, reading, achievable_w,
|
||||
claim can NEVER produce `lo > hi` in the resolver - a
|
||||
contradiction there resolves to 0 W, which would park the
|
||||
battery in the exact minute it should be discharging hardest.
|
||||
`soc` SAFETY-24. MEASURED state of charge, percent. None when the
|
||||
sensor for it did not answer - which is floor-limited, not
|
||||
permission.
|
||||
`soc_floor` SAFETY-24. The percent below which this guard may not spend
|
||||
the pack for money. REQUIRED, and deliberately without a
|
||||
default: a default here would be CFG-03's fourth defaults
|
||||
site and TEST-14's quiet fallback in one line.
|
||||
"""
|
||||
ceiling, from_where = quarter_ceiling_w(cap_w, reading)
|
||||
ceil_top = abs(float(achievable_w))
|
||||
@@ -454,12 +625,41 @@ def decide(projection, *, batt_w, cap_w, reading, achievable_w,
|
||||
wanted_w=wanted,
|
||||
reason="the load is under the level this quarter can afford")
|
||||
|
||||
# SAFETY-24 - AND ONLY HERE. `wanted > 0` is now established, so a forced
|
||||
# discharge really is being asked for and the SoC is the quantity that
|
||||
# decides whether it may be sized. Asked one line earlier it would grade a
|
||||
# number that governs nothing on every quiet cycle of the day, and would
|
||||
# report "floor-limited" over a guard that was never going to discharge.
|
||||
denied = discharge_permitted(soc, soc_floor)
|
||||
if denied is not None:
|
||||
# 0.0, not `wanted`, and not a negative number. Zero forbids CHARGING -
|
||||
# one-directional, cannot cost pack energy - and forbids nothing else;
|
||||
# a `lo` limit structurally cannot cap the discharge the loop is already
|
||||
# doing. See the module note: this bounds THE GUARD's forced discharge,
|
||||
# not the grid-following loop, which still has no SoC guard.
|
||||
return PeakDecision(
|
||||
engaged=True, floor_w=0.0, ceiling_w=ceiling,
|
||||
ceiling_from=from_where, projected_w=projected, excess_w=ex,
|
||||
wanted_w=wanted, floor_limited=True, soc=soc, soc_floor=soc_floor,
|
||||
soc_floor_reason=denied,
|
||||
reason=(
|
||||
f"PEAK GUARD FLOOR-LIMITED: the quarter projects "
|
||||
f"{projected:.0f} W against a {ceiling:.0f} W ceiling "
|
||||
f"({from_where}) and {wanted:+.0f} W of discharge would hold "
|
||||
f"it, but {denied}"
|
||||
+ ("" if soc is None else f" ({float(soc):.0f} %")
|
||||
+ ("" if soc is None or soc_floor is None
|
||||
else f" vs {float(soc_floor):.0f} %")
|
||||
+ ("" if soc is None else ")")
|
||||
+ " - commanding no forced discharge, so THIS QUARTER WILL GO "
|
||||
"OVER THE CEILING. Charging stays blocked (floor 0 W)"))
|
||||
|
||||
floor = min(wanted, ceil_top)
|
||||
saturated = floor < wanted
|
||||
return PeakDecision(
|
||||
engaged=True, floor_w=floor, ceiling_w=ceiling, ceiling_from=from_where,
|
||||
blind=None, projected_w=projected, excess_w=ex, wanted_w=wanted,
|
||||
saturated=saturated,
|
||||
saturated=saturated, soc=soc, soc_floor=soc_floor,
|
||||
reason=(
|
||||
f"PEAK GUARD: quarter projects {projected:.0f} W against a "
|
||||
f"{ceiling:.0f} W ceiling ({from_where}) with "
|
||||
@@ -513,5 +713,13 @@ def claim(decision: PeakDecision) -> Claim | None:
|
||||
"""
|
||||
if not decision.engaged or decision.floor_w is None:
|
||||
return None
|
||||
# Three reasons, not two. A `lo = 0 W` claim reaches the arbiter from THREE
|
||||
# different states now - blind, floor-limited, and a genuine floor that
|
||||
# happens to be zero - and the arbiter's explain() is what an operator reads
|
||||
# when the battery stops charging. Spelling them the same way would make the
|
||||
# SAFETY-24 case indistinguishable from the SAFETY-18 one on the one line
|
||||
# that gets read.
|
||||
return Claim.limit(SOURCE, P_PEAK, lo=float(decision.floor_w),
|
||||
reason=("blind" if decision.blind else "quarter peak"))
|
||||
reason=("blind" if decision.blind
|
||||
else "SoC floor" if decision.floor_limited
|
||||
else "quarter peak"))
|
||||
|
||||