SMA-2: each inverter is reached through a driver; GoodWe behaviour unchanged
app/drivers.py holds one Driver per roster entry (configured, actuator_id, limits, read, write, release, probe, link_stale_s, batt_bound, settle_s, brand, words). GoodWeEsphomeDriver makes the calls the code it replaced made, in the same order. Inverter gets driver; has_writer, is_live and link_note read it. The SoC/power read, the write, the device range (run_control, amain, the settings panel), rule 2 per unit and the SAFETY-28 census go through it. setpoint_entity is optional per entry beside driver, host, port, unit_id and maintenance; only goodwe_esphome is selectable, the rest are checked and unused. Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
23ff9d0920
commit
e56eeef8f0
@@ -1536,8 +1536,9 @@ _decl9 = dict(ln.strip().lstrip("- ").split(": ", 1)
|
||||
for ln in _entry9.splitlines()[1:] if ": " in ln)
|
||||
print(f" the shipped per-entry schema: {_decl9}")
|
||||
check("...and the schema half declares it as a LIST OF OBJECTS whose `name`, "
|
||||
"`setpoint_entity`, `max_w` and `bms_soc_floor` are REQUIRED - no "
|
||||
"trailing `?` - so the Supervisor refuses a half-written entry before the "
|
||||
"`max_w` and `bms_soc_floor` are REQUIRED - no "
|
||||
"trailing `?` (SMA-2: `setpoint_entity` is the GoodWe driver's own key "
|
||||
"and optional here; rule 9(d) requires it per driver) - so the Supervisor refuses a half-written entry before the "
|
||||
"add-on sees it, and an entry can never fall back on a sibling's rating "
|
||||
"or on a sibling's BMS cut-out because there is no entry without one. "
|
||||
"⚠️ SAFETY-32 ADDED THE FOURTH ONE AS REQUIRED RATHER THAN AS "
|
||||
@@ -1553,13 +1554,14 @@ check("...and the schema half declares it as a LIST OF OBJECTS whose `name`, "
|
||||
"refuses every options blob written before it existed",
|
||||
set(_decl9) == {"name", "setpoint_entity", "max_w", "bms_soc_floor",
|
||||
"soc_entity", "batt_entity", "batt_invert",
|
||||
"capacity_kwh"}
|
||||
"capacity_kwh", "driver", "host", "port", "unit_id",
|
||||
"maintenance"}
|
||||
and not any(_decl9[k].endswith("?")
|
||||
for k in ("name", "setpoint_entity", "max_w",
|
||||
"bms_soc_floor"))
|
||||
for k in ("name", "max_w", "bms_soc_floor"))
|
||||
and all(_decl9[k].endswith("?")
|
||||
for k in ("soc_entity", "batt_entity", "batt_invert",
|
||||
"capacity_kwh")))
|
||||
for k in ("setpoint_entity", "soc_entity", "batt_entity",
|
||||
"batt_invert", "capacity_kwh", "driver", "host",
|
||||
"port", "unit_id", "maintenance")))
|
||||
|
||||
# ⚠️ NOTHING IS INHERITED, AND THIS IS DEV-02 RESTATED AS A CONFIG RULE.
|
||||
# ⚠️ THE FLAT KEYS ARE SET TO REAL ENTITIES HERE, AND THAT IS THE WHOLE CHECK.
|
||||
|
||||
Reference in New Issue