EV-20: SPIKE-05 decisions C1, C6, C9 (brief v5) with rows for C1, C5, C6, C8, C9
checks / unit (pull_request) Successful in 34m42s
infra-pin / fresh (pull_request) Successful in 2s

C1: an own 0 A not yet read back is kept with the mode; a start in Off with
it writes the 0 A (retried), without it nothing; a start that will not write
warns once when the charger still has the add-on's current. C6: Solar's 30 s
gate also counts from Manual's latest write. C9: an exit also owes its 0 A
when the read-back shows Solar's own value. Rows for C5 and C8 too.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
This commit is contained in:
Claude
2026-11-22 21:33:28 +01:00
parent d18ed56fad
commit e0138a2ae5
8 changed files with 282 additions and 5 deletions
+1
View File
@@ -1070,6 +1070,7 @@ class CycleMixin:
await self.check_charger()
await self.check_car_over()
await self.check_car_release() # EV-20 (D3)
await self.check_car_start() # EV-20 (C1)
self.car_kick() # EV-04/20: in the background
await self.check_fixed_note()