MAINT-28 fix round 5: while the pause holds, the batteries give only what the guard needs
H-1: one site limit while the pause holds (the period's largest floor, never under this cycle's), so the other pack no longer gives for the house. New live-try test (A 11 %, B 25 %, 90 min at 6.5 kW) red on 07d23d2. M-1: a 45-min rig-shape test that goes red when the settled check is forced True. M-2/L-2: DECISIONS. CHANGELOG line. test_safety84 n2_charge_banked re-pinned (quarters 3349 and 3950 W, aim 3950 W).
Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
9a76f1a968
commit
de06a2c6f5
@@ -14,12 +14,12 @@ Why 300 W: the house wanders +-50 W; once the charge resumes it settles at (aim
|
||||
|
||||
The flag lives only while the charge-only branch is taken: every cycle that reaches the maintenance loop starts it at False, so a maintenance that ended, a mode change or a missing aim cannot carry a stale True into the next charge (test_maint28.py part 1b). `cycle()` has two returns before that loop, and the flag is kept through them on purpose: "inputs missing" and "readings late" (SAFETY-128) are holds of under `stale_after` seconds that write nothing and decide nothing, so the next full cycle sees the same charge and the same peak. A missed poll must not end a peak pause; a reset there would restart the charge on it (`_maint_shape_suspended` is kept through them the same way).
|
||||
|
||||
It only ever keeps the maintenance charge off. No cut-back is delayed or weakened: the guard's claim is filed as before. While the pause is held the loop works as at 02eac3b, so A also gives for the house (quarters then sit under the aim, A's energy goes to the load: 1.67 kWh in the 45 min below, 0.45 kWh on 1b5f7c9). Measured alternative, A capped at 0 W while held and the guard idle (review scratch, same 45 min run): A gives 0.44 kWh in the load instead of 1.66, quarters 5919/5915 W, but A switches give/idle 32 times in 40 min. The uncapped give costs ~1.2 kWh round trip per 45-min peak (a few cents) and ~50 min more maintenance charge, far inside the 36 h timeout, so the steady give is kept.
|
||||
It only ever keeps the maintenance charge off. No cut-back is delayed or weakened: the guard's claim is filed as before. While the pause is held, the pack in CHARGE gives only its share of the guard's floor (0 W if the guard holds it at its reserve), and the batteries together give only what the guard needs (see Fix-forward, F-2 and H-1). The first version let A give for the house; it was dropped.
|
||||
|
||||
## Numbers (sim, real `cycle()`, A rated 2500 W)
|
||||
House 3000 -> 6500 W for 45 min -> 3000 W, +-50 W every 5 s, banked month peak 6000 W (aim 5950 W), forecast = quarter average so far plus the rest at the present grid (`scratch/MAINT-28/dev/m28_repro.py`; `test_maint28.py` runs the same shape for 15 min to keep the suite short).
|
||||
|
||||
| 45 min load | base 02eac3b | 1b5f7c9 | MAINT-28 |
|
||||
| 45 min load | base 02eac3b | 1b5f7c9 | MAINT-28 (f3f9483, without the lag) |
|
||||
|---|---|---|---|
|
||||
| A charge/give reversals | 0 | 52 | 1 (the first trip) |
|
||||
| A charging seconds in the load (of 2700) | 0 | 367 | 301 (before the first trip) |
|
||||
@@ -40,14 +40,16 @@ The sim had no battery-reading lag, and the first version said the 300 W line is
|
||||
|
||||
**F-1: the pause ends only on a settled estimate.** `Controller._batts_settled()` is False from a step UP of a unit's command (`MAINT_STEP_W` = 100 W more give or less charge, the SAFETY-128 pending size) until its reading changed `PLANT_SETTLE_S` (6 s) after the step, or `BATT_OBLIGED_S` (17 s) have passed. `peakguard.shaping_held(..., settled)` then keeps the pause. A step down makes the estimate err high, which only holds the pause, so it waits for nothing. Measured in the 45 min sim, pause on: settled, the estimate was at most 146 W under the real house (0 cycles over 300 W); not settled, up to 1933 W under (725 of 1611 cycles over 300 W). Sim, 45 min, house 6500 W: 83 of 83 releases on a stale estimate (f3f9483) -> 0; flips 148 -> 1 (1b5f7c9 210). Charge is back 4 s after the load (12 s in test_maint28b), not 0: the first settled estimate. No cut-back is touched.
|
||||
|
||||
**F-2 and the cap.** Owner 2026-11-13 ("1" = cap): while the pause holds, the pack in maintenance CHARGE gives only what the guard claims for the peak, at any SoC; other packs unchanged. Owner 2026-11-13 ("ok max", relayed by the manager): accepted "while the hold is on, the pack in maintenance CHARGE gives at most the largest floor the peak guard claimed in the current quarter" (about 0.37 kWh per 45-min peak in the sim; quarters at or under the aim).
|
||||
**F-2 and the cap.** Owner 2026-11-13 ("1" = cap): while the pause holds, the pack in maintenance CHARGE gives only what the guard claims for the peak, at any SoC; other packs unchanged (replaced by H-1 below). Owner 2026-11-13 ("ok max", relayed by the manager): accepted "while the hold is on, the pack in maintenance CHARGE gives at most the largest floor the peak guard claimed in the current quarter" (about 0.37 kWh per 45-min peak in the sim; quarters at or under the aim).
|
||||
|
||||
**H-1 (review 2026-11-14, owner decision 2026-11-14): the batteries together give only what the guard needs.** With the cap on A alone, the loop gave for the whole house with B (Cheap hours): in the live-try shape (A 11 % in CHARGE, B 25 %, house 6.5 kW for 90 min) B gave 4.6 kW, went from 25 to 10 % in 43 min, and two quarters were 6502 and 6499 W against the month peak 6000 W. So while the pause holds, `_m28_share()` also files one site limit (source `charge`, `P_MAINT_SHAPE`, per-site `_m28_site`): `hi` = the largest floor of the period, never under this cycle's floor. The guard's claim is not cut: `hi` is at least the floor, `P_PEAK` outranks `P_MAINT_SHAPE`, and `_peak_on_able` still places the whole floor. Outside the hold nothing is filed. Live try, same shape (test_maint28b): quarters 5357 to 5911 W (aim 5950), B 0.86 kWh and ends at 20.6 % (1b5f7c9: 1.0 kWh, 19.8 %), B switches give/idle once, A never. The re-pinned `n2_charge_banked` quarters are 3349 and 3950 W (aim 3950).
|
||||
|
||||
The rule as built (`Controller._m28_share()`): while the pause holds (N>=2, month aim above the cap) the pack gets a unit limit `hi` = the largest part of the guard's floor placed on it in this 15-minute period. Its part in a cycle is the floor less what the other units are placed at in this cycle's split without that limit, so a part the guard's split puts on the other pack is not this pack's. A pack the guard holds at its reserve (`peak_guard.held`) gets 0 W and its part starts again from 0 W. The largest part is kept per unit (`_m28_hi`, keyed by the unit) and dropped in a new period or when the pause ends; only one pack can be in maintenance CHARGE anyway (`maintenance.arbitrate()`, one slot per site).
|
||||
|
||||
Why the largest of the period and not the present part: the guard alone lands the quarter 9.5-10 W over its aim in the sim (SAFETY-126: its own projection ends on 5950.0 W but the meter reading it counts lags the true grid), and with the present part only, test_maint28 part 1 ends at 5960.1 W; the largest of the period lets the loop keep A up and it ends at 5925 W. Why not `hi` = 0 W: with the other pack under its reserve the guard needs this one (test_maint28b, house 12 kW, B at 18 %: A gives 1.07 kWh for the guard).
|
||||
|
||||
Tests (test_maint28b, 13-min load, A 5 kW): A at 49 %: SoC drop 0.64 point (the owner's 0.37 kWh per 45 min is 0.70 point here; the check is <= 0.70). Both packs able, B on Cheap hours: B is placed nothing, A's limit is the period's largest floor (3087 W) and A gives 3081 W. B on Solar first (gives for the house): A's limit 3294 W against a period's largest floor of 6284 W, under it by 500 W or more in 564 of 569 paused cycles; A still gives 3294 W, so the quarter ends 3843 W, far under the aim: that is the cost of the largest-of-period rule when the other pack gives for the house.
|
||||
Tests (test_maint28b, 13-min load, A 5 kW): A at 49 %: SoC drop 0.64 point (the owner's 0.37 kWh per 45 min is 0.70 point here; the check is <= 0.70). Both packs able, B on Cheap hours: B is placed nothing, A's limit is the period's largest floor (3087 W) and A gives 3081 W. B on Solar first (it gives for the house): A's limit stays under the period's largest floor by 500 W or more in 740 of 744 paused cycles, and the quarters stay under the aim.
|
||||
|
||||
Sim, rig shape, 45 min, house 6500 W: A in CHARGE at 49 %: A gives 0.17 kWh (f3f9483 0.44), SoC 50.5 -> 49.0 %, charge/give flips 1, give/idle switches 3, quarters 5358 1663 1899 2572 4476 W, charge back 4 s after the load; B (Cheap hours, not in maintenance) gives 3.04 kWh for the house (f3f9483 0.32). B at 18.2 % in CHARGE: f3f9483 gave 1.89 kWh to 10.0 %; now 0.00 kWh, 18.2 %, quarters 5948 and 5952 W (the guard alone, on A). test_safety84 n2_charge_banked: banked quarters 3349 and 3217 W against the aim 3950 W.
|
||||
Sim, rig shape, 45 min, house 6500 W (load from minute 10), A in CHARGE at 49 %, B 30 % on Cheap hours: A gives 0.17 kWh (f3f9483 0.44), SoC 50.5 -> 49.0 %, charge/give flips 1, give/idle switches 1, quarters 5358 5897 5911 5176 4477 W, charge back 4 s after the load; B gives 0.23 kWh (before H-1 3.04, f3f9483 0.32). test_safety84 n2_charge_banked: banked quarters 3349 and 3950 W against the aim 3950 W.
|
||||
|
||||
Mutants, each red: the freshness check dropped (always settled); the cap dropped; the other units' placement dropped (part = the whole floor); one cap for the site instead of per unit; the 0 W for a held pack dropped (all in `test_maint28b.py`); the period's largest dropped (present part only: `test_maint28.py` part 1 quarter 5960 W).
|
||||
Mutants, each red: the freshness check dropped (always settled); the cap dropped; the other units' placement dropped (part = the whole floor); one cap for the site instead of per unit; the 0 W for a held pack dropped (all in `test_maint28b.py`); the period's largest dropped (present part only: `test_maint28.py` part 1 quarter 5960 W); `_batts_settled()` replaced by True at the hold in ctl_cycle.py (the 45-min rig shape in `test_maint28b.py`, one stale release); the site limit dropped (the live try in `test_maint28b.py`: quarters 6502 and 6499 W, B 2.91 kWh to 10.0 %).
|
||||
|
||||