SAFETY-94 review: tests for three surviving mutants; record two gaps
- test_safety94 part 4: time under 250 W is not counted; a command that swaps direction every cycle is never refusal evidence; a reading moving away from the ask does not restart the evidence. These kill review mutants R1, R3 and R6, which survived the PR's tests. - DECISIONS: at N=1 a battery with B's standby offset no longer latches a refusal (SAFETY-97 now covers N=1); a part-time ask is caught after 35/d s of wall time. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
6759d21ea5
commit
dd5eb6fdc8
@@ -88,7 +88,15 @@ the held number for one 35 s window of asking, so 35 < 75 < 85 still holds.
|
||||
## Known gaps
|
||||
|
||||
- B's standby offset (-95 to -118 W at idle) puts a refusing B outside the
|
||||
100 W band some of the time, so a refusing B may not latch. Pre-existing,
|
||||
not touched here.
|
||||
100 W band some of the time, so a refusing B may not latch (SAFETY-97).
|
||||
At N=2 this is unchanged. **At N=1 it is new:** the old one-instant check
|
||||
caught such a battery in 17-105 s; the shared rule needs 12 cycles in the
|
||||
band in a row and, on the review probe, never latched in 1200 s.
|
||||
- A command that asks only part of the time (a fraction d) is caught after
|
||||
35 s of asking, which is 35/d s of wall time (0/1500 W every 5 s: 69 s).
|
||||
SAFETY-30's per-unit check restarts when its command stops opposing the
|
||||
held reading, which a lapsing ask normally does, so 35 < 85 holds there.
|
||||
SAFETY-31's circulation check (75 s) ignores the command, so its margin
|
||||
holds only while d >= 0.47.
|
||||
- A register frozen under a command that stays near the 250 W travel edge
|
||||
is caught late or not at all (survivor 2).
|
||||
|
||||