SAFETY-83: peak guard outranks the maintenance drain at N=1
At N=1 the drain is the site SET at P_MAINTENANCE (60), so the peak floor
(P_PEAK, 50) was not applied and the house imported what the drain left.
Where the floor asks for more than the drain rate, main.py now refiles the
peak claim at P_MAINTENANCE, so it wins; safety SETs still park everything.
Nothing else changes: safety78_identity --diff against 35cdffe changes only
cycles where the guard wanted more than the drain; N=2 is byte-identical.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -0,0 +1,234 @@
|
||||
"""Runnable check for SAFETY-83: the peak guard outranks the drain at N=1.
|
||||
`python3 test_safety83.py`
|
||||
|
||||
At one inverter the monthly drain is the site SET at P_MAINTENANCE, above the
|
||||
peak floor, so the house imported what the drain left and quarters went over
|
||||
the peak limit. Now a peak floor above the drain rate is refiled at
|
||||
P_MAINTENANCE and wins. Drives the REAL Controller (tools/opt11_identity.py's
|
||||
harness on a P1 meter). DECISIONS/SAFETY-83-peak-over-drain.md has the record.
|
||||
|
||||
1. A house of 5000, 6000 and 7000 W during a drain, limits 2500 and 3500,
|
||||
margins 0 and 50: every quarter banks at or under the aim, the drain keeps
|
||||
running, and without the fix the same runs go over.
|
||||
2. The drain never makes the banked quarter worse than no drain, below and
|
||||
above the drain rate; below it the rest is still exported.
|
||||
3. The drain still ends, and the order holds: a lost reading parks the
|
||||
battery, the rating caps the floor without a clash.
|
||||
4. Only cycles where the guard wanted more than the drain change, and N=2 is
|
||||
untouched.
|
||||
|
||||
Mutations (MUTATION.md, purged copies) are listed in the pull request.
|
||||
"""
|
||||
|
||||
import functools
|
||||
import logging
|
||||
import os
|
||||
import sys
|
||||
import tempfile
|
||||
|
||||
HERE = os.path.dirname(os.path.abspath(__file__))
|
||||
sys.path.insert(0, HERE)
|
||||
sys.path.insert(0, os.path.join(HERE, "tools"))
|
||||
logging.disable(logging.WARNING)
|
||||
|
||||
import opt11_identity as rig # noqa: E402
|
||||
import safety78_identity as s78 # noqa: E402
|
||||
import safety79_identity as s79 # noqa: E402
|
||||
from app.arbiter import P_MAINTENANCE, P_PEAK # noqa: E402
|
||||
from app.main import Controller # noqa: E402
|
||||
from app.maintenance import CHARGE, DRAIN # noqa: E402
|
||||
|
||||
fails = []
|
||||
TOL = 1.0 # watts over the aim a banked quarter may show
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def run(house, cap, margin, drain_w, *, maint=True, dur=2700.0, soc=None,
|
||||
before=None, store=None, **extra):
|
||||
"""N=1 on a P1 meter; returns (rows, controller, banked quarters)."""
|
||||
opts = dict(s79.P1, peak_cap_w=cap, peak_margin_w=margin, **extra)
|
||||
if maint:
|
||||
opts.update(maintenance_enabled=True, maintenance_start_hour=11,
|
||||
maintenance_discharge_w=drain_w)
|
||||
db = os.path.join(tempfile.mkdtemp(prefix="s83-"), "tariff.db")
|
||||
real = rig.Controller
|
||||
rig.Controller = functools.partial(real, peak_db_path=db)
|
||||
try:
|
||||
rows, c = rig.run(1, extra=opts, dur=dur,
|
||||
load=house if callable(house) else lambda t: house,
|
||||
soc=soc or (lambda u, t: 60.0),
|
||||
cut=lambda u, t: False, before=before or s79._feed,
|
||||
store=store)
|
||||
finally:
|
||||
rig.Controller = real
|
||||
return rows, c, {b.start.strftime("%H:%M"): b.offtake_avg_w
|
||||
for b in c.p1.blocks}
|
||||
|
||||
|
||||
def without_fix(fn):
|
||||
real = Controller._peak_over_drain
|
||||
Controller._peak_over_drain = lambda self, claims, results: None
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
Controller._peak_over_drain = real
|
||||
|
||||
|
||||
def cmd(r):
|
||||
return dict(r[2])["a"]
|
||||
|
||||
|
||||
# ============================================================================ #
|
||||
print("1. banked quarters during a drain, N=1")
|
||||
CASES = [(cap, drain, m, h) for cap, drain in ((2500, 2000), (3500, 2500))
|
||||
for m in (0, 50) for h in (5000.0, 6000.0, 7000.0)]
|
||||
RES, OLD = {}, {}
|
||||
for k in CASES:
|
||||
cap, drain, m, h = k
|
||||
RES[k] = run(h, cap, m, drain)
|
||||
OLD[k] = without_fix(lambda: run(h, cap, m, drain))
|
||||
print(f" limit {cap} drain {drain} margin {m:>2} house {h:.0f}: "
|
||||
f"banked {[round(v) for v in RES[k][2].values()]} W "
|
||||
f"(before the fix {[round(v) for v in OLD[k][2].values()]} W)")
|
||||
check("⭐ every quarter banks at or under the aim (limit - margin) plus 1 W, "
|
||||
"for a 5000, 6000 and 7000 W house, limits 2500 and 3500, margins 0 "
|
||||
"and 50",
|
||||
all(len(b) >= 2 and max(b.values()) <= k[0] - k[2] + TOL
|
||||
for k, (_r, _c, b) in RES.items()))
|
||||
check("⭐ the drain keeps running: the phase is drain on every run and the "
|
||||
"battery gives at least the drain rate on every cycle",
|
||||
all(c.maints[0].phase == DRAIN and all(cmd(r) >= k[1] for r in rows)
|
||||
for k, (rows, c, _b) in RES.items()))
|
||||
check("...and where the house is over drain + aim, the battery gives more "
|
||||
"than the drain rate, bound by the peak floor",
|
||||
all(any(cmd(r) > k[1] and "limited by peak" in r[6] for r in rows)
|
||||
for k, (rows, _c, _b) in RES.items() if k[3] - k[1] > k[0] - k[2]))
|
||||
check("non-vacuous: without the fix the same runs bank over the limit "
|
||||
"wherever the house is above drain + aim (the reported defect: 3000 W "
|
||||
"at a 5000 W house against 2500 W)",
|
||||
all(max(b.values()) > k[0] + 100.0 for k, (_r, _c, b) in OLD.items()
|
||||
if k[3] - k[1] > k[0])
|
||||
and round(OLD[(2500, 2000, 50, 5000.0)][2]["11:15"]) == 3000)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n2. the drain never makes the banked quarter worse, N=1")
|
||||
CAP, DRAIN_W, MARGIN = 3500, 2500, 50 # the owner's settings
|
||||
AIM = CAP - MARGIN
|
||||
WORSE = {}
|
||||
for h in (1200.0, 3000.0, 5000.0, 6500.0, 7000.0):
|
||||
_rows, _c, b = run(h, CAP, MARGIN, DRAIN_W)
|
||||
_r0, _c0, b0 = run(h, CAP, MARGIN, DRAIN_W, maint=False)
|
||||
WORSE[h] = (b, b0, _rows)
|
||||
print(f" house {h:.0f}: with the drain {[round(v) for v in b.values()]}"
|
||||
f" W, without {[round(v) for v in b0.values()]} W")
|
||||
check("⭐ below and above the drain rate, every quarter with the drain banks "
|
||||
"no more than the larger of the aim and the same quarter without it",
|
||||
all(b[q] <= max(AIM, b0[q]) + TOL for b, b0, _r in WORSE.values()
|
||||
for q in b))
|
||||
_r12 = WORSE[1200.0][2]
|
||||
check("below the drain rate the battery gives the drain rate and exports the "
|
||||
"rest (owner, 2026-09-29): 2500 W against a 1200 W house",
|
||||
all(cmd(r) == DRAIN_W for r in _r12[1:]))
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n3. the drain ends, and the order holds")
|
||||
_e_rows, _e, _eb = run(6500.0, CAP, MARGIN, DRAIN_W, dur=1200.0,
|
||||
soc=lambda u, t: max(5.0, 60.0 - t / 20.0))
|
||||
check("⭐ with the guard binding, the drain still reaches its floor and moves "
|
||||
"to the charge phase, with no abort",
|
||||
_e.maints[0].phase == CHARGE
|
||||
and not any("abort" in e.lower() for e in _e.events))
|
||||
|
||||
|
||||
def blind_at(t0):
|
||||
"""The battery power reading goes missing at `t0`: a safety SET."""
|
||||
def before(c, t):
|
||||
s79._feed(c, t)
|
||||
if t >= t0 and not getattr(c.hass, "_blind", False):
|
||||
real = c.hass.number
|
||||
|
||||
async def number(e, invert=False):
|
||||
return None if e == "sensor.batt_a" else await real(e, invert)
|
||||
c.hass.number, c.hass._blind = number, True
|
||||
return before
|
||||
|
||||
|
||||
_s_rows, _s, _sb = run(6500.0, CAP, MARGIN, DRAIN_W, dur=600.0,
|
||||
before=blind_at(300.0))
|
||||
print(f" reading lost at 300 s: last {cmd(_s_rows[-1]):+.0f} W, "
|
||||
f"{_s_rows[-1][6]}")
|
||||
check("⭐ a safety SET outranks the refiled peak floor: before the reading "
|
||||
"goes the battery gives above the drain rate, after it it is at 0 W",
|
||||
any(cmd(r) > DRAIN_W for r in _s_rows if r[0] < 300.0)
|
||||
and all(cmd(r) == 0.0 for r in _s_rows if r[0] >= 400.0)
|
||||
and _s_rows[-1][6].startswith("safety -> 0 W"))
|
||||
_m_rows, _m, _mb = run(7000.0, 2500, 50, 2000, dur=900.0, max_w=3000)
|
||||
print(f" max_w 3000, house 7000: last {cmd(_m_rows[-1]):+.0f} W, "
|
||||
f"{_m_rows[-1][6]}")
|
||||
check("⭐ the rating caps the floor without a clash: at max_w 3000 the "
|
||||
"battery gives 3000 W, never 0 W, and nothing contradicts",
|
||||
all(cmd(r) >= 2000.0 for r in _m_rows)
|
||||
and cmd(_m_rows[-1]) == 3000.0
|
||||
and not any("CONTRADICTION" in (r[6] or "") for r in _m_rows))
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n4. only the cycles where the guard wanted more change")
|
||||
|
||||
|
||||
def promoted(row):
|
||||
return [c for c in row[-1][0] if c[0] == "peak"]
|
||||
|
||||
|
||||
_id = {k: s78.run(**v)[0] for k, v in s78.SCENARIOS.items()}
|
||||
_bad = []
|
||||
for k, rows in _id.items():
|
||||
for r in rows:
|
||||
claims, guard = r[-1][0], r[-1][1]
|
||||
rate = [c[3] for c in claims if c[0] == "maintenance" and c[2] == "set"]
|
||||
pk = promoted(r)
|
||||
if k.startswith("n2"):
|
||||
ok = all(c[1] == P_PEAK for c in pk)
|
||||
elif s78.wanted_more(r):
|
||||
ok = ([c[1] for c in pk] == [P_MAINTENANCE]
|
||||
and r[1] == guard[1] and "limited by peak" in r[6])
|
||||
else:
|
||||
ok = (all(c[1] == P_PEAK for c in pk)
|
||||
and (not rate or r[1] == rate[0]))
|
||||
if not ok:
|
||||
_bad.append((k, r[0], r[1], r[6], pk))
|
||||
_more = {k: sum(map(s78.wanted_more, rows)) for k, rows in _id.items()}
|
||||
print(f" cycles with the guard above the drain: {_more}; bad {_bad[:3]}")
|
||||
check("⭐ at N=1, on every cycle where the guard asks for more than the drain "
|
||||
"the peak claim is refiled at P_MAINTENANCE and the target is its floor; "
|
||||
"on every other cycle the peak claim stays at P_PEAK and the target is "
|
||||
"the drain rate",
|
||||
not _bad and all(_more[k] > 50 for k in _id if k.startswith("n1")))
|
||||
check("⭐ at N=2 the peak claim is never refiled (the SAFETY-78 floor does "
|
||||
"that job), and test_safety78.py part 5 holds N=2 to the digests of "
|
||||
"release/1.0 35cdffe", not _bad)
|
||||
|
||||
|
||||
|
||||
def store_hold():
|
||||
st = rig._Store()
|
||||
st.data["phase"], st.data["phase_started"] = "hold", rig.BASE.isoformat()
|
||||
return st
|
||||
|
||||
|
||||
_h_rows, _h, _hb = run(6000.0, 2500, 50, 2000, dur=600.0, store=store_hold())
|
||||
check("a maintenance HOLD at N=1 is not changed (DECISIONS/SAFETY-83, not "
|
||||
"changed): the battery stays at 0 W with the house over the limit",
|
||||
_h.maints[0].phase == "hold" and _h.peak_guard.engaged
|
||||
and _h.peak_guard.floor_w > 0.0
|
||||
and all(cmd(r) == 0.0 for r in _h_rows))
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: {', '.join(fails)}")
|
||||
sys.exit(1)
|
||||
print("all checks passed")
|
||||
Reference in New Issue