OPT-11 P1: per-battery mode limits, on/off, solar order
A battery's mode is a soft unit limit (source `mode`, P_MODE 35) kept
apart from the hard limits in pre_resolve(). The allocator applies it
only while the site target is decided at or below 35 (new
Resolution.deciding_priority), so the peak floor releases it and a mode
`hi` never meets the site `lo`. At N=1 resolve() applies the same rule
to the site target after stage 2. A mode range without 0 W is dropped
as a software fault, so REFUSE_SIGN stays unreachable from a mode.
compute() gets the loop bound (sum over live units of hard limits with
modes applied), so the loop never asks for watts no battery may give
and the saturation freeze never parks on them. While charging, Leftover
solar weighs 0 so Solar first fills first. Store keys pack_use and
pack_mode per battery, set by two new /action values; Off stops and
skips maintenance with a log line. Minimal Batteries cards (EN/NL).
Off by default (battery_modes_enabled); off, commands are byte-identical
to a5dddad at N=1 and N=2 (test_modes.py part 1).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -82,6 +82,9 @@ configuration:
|
||||
estop_fitted:
|
||||
name: "Hardware · RS485 emergency stop is fitted"
|
||||
description: "Switch this on if the emergency stop is installed. It only changes a warning on the status page."
|
||||
battery_modes_enabled:
|
||||
name: "Hardware · Battery modes"
|
||||
description: "Give each battery an on and off switch and a mode, set on the Batteries screen."
|
||||
pv_entity:
|
||||
name: "Hardware · Solar production entity (W)"
|
||||
description: "Optional. Your solar inverter's power sensor, positive while producing. The add-on records it and does not use it for control."
|
||||
|
||||
@@ -63,6 +63,9 @@ configuration:
|
||||
estop_fitted:
|
||||
name: "Hardware · RS485-noodstop is geplaatst"
|
||||
description: "Zet dit aan als de noodstop geïnstalleerd is. Het verandert alleen een waarschuwing op de statuspagina."
|
||||
battery_modes_enabled:
|
||||
name: "Hardware · Batterijmodi"
|
||||
description: "Geef elke batterij een aan- en uitschakelaar en een modus, in te stellen op het scherm Batterijen."
|
||||
pv_entity:
|
||||
name: "Hardware · Entiteit zonneproductie (W)"
|
||||
description: "Optioneel. De vermogenssensor van uw zonne-omvormer, positief tijdens productie. De add-on houdt ze bij en regelt er niet mee."
|
||||
|
||||
Reference in New Issue