OPT-11 P1: per-battery mode limits, on/off, solar order
A battery's mode is a soft unit limit (source `mode`, P_MODE 35) kept
apart from the hard limits in pre_resolve(). The allocator applies it
only while the site target is decided at or below 35 (new
Resolution.deciding_priority), so the peak floor releases it and a mode
`hi` never meets the site `lo`. At N=1 resolve() applies the same rule
to the site target after stage 2. A mode range without 0 W is dropped
as a software fault, so REFUSE_SIGN stays unreachable from a mode.
compute() gets the loop bound (sum over live units of hard limits with
modes applied), so the loop never asks for watts no battery may give
and the saturation freeze never parks on them. While charging, Leftover
solar weighs 0 so Solar first fills first. Store keys pack_use and
pack_mode per battery, set by two new /action values; Off stops and
skips maintenance with a log line. Minimal Batteries cards (EN/NL).
Off by default (battery_modes_enabled); off, commands are byte-identical
to a5dddad at N=1 and N=2 (test_modes.py part 1).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -10,6 +10,7 @@
|
||||
"parts": {
|
||||
"meter.timing": {"name": "Timing"},
|
||||
"inverters.solar": {"name": "Zonnepanelen"},
|
||||
"inverters.modes": {"name": "Batterijmodi"},
|
||||
"tariff.selling": {"name": "Laden en verkopen op prijs"},
|
||||
"tariff.feed": {"name": "Details van de prijsfeed"},
|
||||
"safety.peak": {"name": "Piekgrens"},
|
||||
@@ -79,7 +80,14 @@
|
||||
"toast": {"started": "Regeling gestart.", "stopped": "Regeling gestopt.", "done": "Klaar.", "failed": "Dat lukte niet. Probeer opnieuw."},
|
||||
"offline": {"name": "Add-on niet bereikbaar", "description": "De pagina probeert het elke 3 seconden opnieuw."},
|
||||
"setup_only": {"name": "Installatie: nog niets wordt geregeld", "description": "Er gaat niets naar een omvormer tot de installatie bewaard is en de add-on herstart.", "control": "De regeling start na de installatie.", "open": "Installatie openen"},
|
||||
"batteries": {"name": "Batterijen", "description": "Batterijmodi en aan- en uitschakelaars komen in een latere update.", "level": "Laadniveau", "now": "Nu", "stored": "Opgeslagen", "mode": "Modus", "settings": "Instellingen van omvormers wijzigen"},
|
||||
"batteries": {"name": "Batterijen", "description": "Zet batterijmodi aan in de instellingen om per batterij een modus te kiezen.", "level": "Laadniveau", "now": "Nu", "stored": "Opgeslagen", "mode": "Modus", "settings": "Instellingen van omvormers wijzigen",
|
||||
"with_modes": {"description": "Elke batterij volgt haar modus, na de piekgrens en de veiligheidsstops."},
|
||||
"use": "Deze batterij gebruiken", "on": "Aan", "off": "Uit",
|
||||
"choice": {
|
||||
"solar_first": {"name": "Eerst zonne-energie", "description": "Laadt met zonne-energie vóór de andere batterijen en dekt het huis."},
|
||||
"leftover_solar": {"name": "Overschot zonne-energie", "description": "Laadt met zonne-energie die de andere batterijen niet opnemen, en dekt het huis."},
|
||||
"off": {"name": "Uit", "description": "De add-on vraagt deze batterij 0 W, behalve als de piekgrens haar nodig heeft."}
|
||||
}},
|
||||
"settings": {"name": "Instellingen", "description": "De instellingen staan hieronder per taak.", "open": "Instellingen openen"}
|
||||
},
|
||||
"choices_later": {"region": {"wallonia": "Wallonië, nog geen standaardwaarde", "brussels": "Brussel, nog geen standaardwaarde"}},
|
||||
@@ -202,6 +210,7 @@
|
||||
},
|
||||
"home_words": {
|
||||
"mode_house": "Volgt het huis",
|
||||
"modes": {"solar_first": "Eerst zonne-energie", "leftover_solar": "Overschot zonne-energie", "off": "Uit"},
|
||||
"attn_shadow": "Schaduwmodus staat aan",
|
||||
"attn_shadow_body": "De add-on beslist alles, maar elke omvormer blijft op 0 W.",
|
||||
"zero_held": "Op 0 W gehouden",
|
||||
|
||||
Reference in New Issue
Block a user