TARIFF-24: battery modes start the tariff task (hotfix 0.19.1)
With battery modes on, a day/night or fixed static_profile, no price feed and arbitrage off, tariff_refresh_wanted() was false: no tariff task, no tariff_plan, mode_runs None, so Leftover solar / Cheap hours never charged from the grid and the Batteries screen said "No prices". packmode.enabled(opts) is now a third term of the gate. With price_provider off the task is pure arithmetic on static_profile, so no HTTPS call is added. Also: version 0.19.1, CHANGELOG entry, DECISIONS note, test_tariff24.py, and a shorter tariff_refresh_wanted() docstring (history stays in DECISIONS). Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
793a67623c
commit
d667f3f3a8
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.19.0"
|
||||
version: "0.19.1"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over its RS485 EMS port by sending it a
|
||||
|
||||
Reference in New Issue
Block a user