EV-05 round 3: a refused way-out 0 A is tried again; one cut per excess
Review of 17a7b29:
- Critical: every way out of Solar (Off, Stop, shadow, safety stop, charger
error, stuck reading, no car) now owes a 0 A until the charger takes it:
tried again 60 s apart, 3 times (EV-04's rule), then the gave-up row and
CHARGER_REFUSED; never over another writer. Shutdown does not trust last_a
while a write of ours is unconfirmed. The card no longer says paused while
the 0 A is not taken.
- Major: an excess episode is taken off the car once, measured from the car's
power when it began, until the car shows it and 15 s more.
Tests: refused-then-accepted 0 A for each exit, a 0 A never taken, shutdown
during a start write's read-back, a cut from 16 A with a slow car; the fuzz
checks refused exits of every kind (N9).
Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
@@ -58,6 +58,22 @@ inputs (`car_sun_inputs`) and runs the writer in the same background task.
|
||||
- **Shadow mode** runs the plan without writing, so the card says what it would
|
||||
set; the charger got its one 0 A when shadow mode came on.
|
||||
|
||||
## Round 3 (review of 17a7b29)
|
||||
|
||||
- **A way-out 0 A is written until the charger takes it** (`SolarWriter.
|
||||
_exit_zero`): Off, Stop, shadow, a safety stop, a charger error, a stuck
|
||||
reading and no car each owe a 0 A; one that is not taken is tried again by
|
||||
EV-04's rule (`RETRY_S` 60 s apart, `MAX_TRIES` 3), then the gave-up row and
|
||||
`CHARGER_REFUSED`. Once taken, or once the charger shows 0 A, nothing more.
|
||||
Never over another writer. A stuck reading cannot confirm a write, so there
|
||||
only a taken write counts (up to 3 tries). At shutdown there is one try, and
|
||||
a write of ours not yet confirmed (cancelled during its read-back) means the
|
||||
current is unknown, so the 0 A is written.
|
||||
- **One excess, one cut** (`SolarPlan.ep`): an excess episode is measured from
|
||||
the car's power when it began, so the same excess is not taken off again
|
||||
while the meter still shows the old power. A new cut needs the car to show
|
||||
the lower power and `CUT_SETTLE_S` (15 s) more for the meter.
|
||||
|
||||
## Solar kWh
|
||||
|
||||
Per cycle in Solar: `min(car power, max(0, spare - room))` Batteries first,
|
||||
|
||||
Reference in New Issue
Block a user