EV-20 SPIKE-06: stuck start cap backs off instead of holding
checks / unit (pull_request) Successful in 44m16s
infra-pin / fresh (pull_request) Successful in 2s

Under one stuck verdict Solar still makes at most MAX_TRIES starts and gives
one CHARGER_REFUSED; then one more start after 15 min and one every 30 min
(each by the start rule and the write clock), so a fault that clears is
found again. The episode ends when the reading follows a start, on a press
of Solar, Off, Manual, shadow or a stop. Rows: cap, backoff times,
recovery, press, episode end; T28 (b) no flapping. DOCS and DECISIONS.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
This commit is contained in:
Claude
2026-11-23 19:01:36 +01:00
parent b99f8c7e52
commit d17f15b33c
5 changed files with 135 additions and 47 deletions
@@ -130,7 +130,10 @@ one small set of facts and derives every path from them:
own may stand (its own 0 A stands, or Solar was just chosen), a stuck
verdict no longer holds Solar: it writes its 0 A first over a current that
is not its own, then the start rule runs; at most MAX_TRIES starts per
verdict, then CHARGER_REFUSED until Solar is pressed. Its write moves the reading (the verdict clears) or is
verdict, then one CHARGER_REFUSED, then one more start after 15 min and
one every 30 min (PM decision: no hold until a press). The episode ends
when the reading follows a start, on a press of Solar, Off, Manual, shadow
or a stop (`_stuck_end`). Its write moves the reading (the verdict clears) or is
refused (EV-04's retries, then CHARGER_REFUSED).
- **No amp ping-pong:** after a step down, a step back up needs
`UP_HYST_W` (100 W) past the amp boundary.
+4 -1
View File
@@ -3361,7 +3361,10 @@ changes at most once per 30 seconds and only by 1 A or more.
stopping the add-on each set the charger to 0 A once. A 0 A the charger does
not take is tried again after a minute, three times, then an amber row says
so. After a restart, or when the charger or Home Assistant answers again,
Solar sets 0 A first and then starts by its own rules. At a stop of the
Solar sets 0 A first and then starts by its own rules. After a stuck
charger reading, Solar tries to start again by its start rule; after three
tries an amber row says so, and it tries once more after 15 minutes, then
every 30 minutes, until the reading follows. At a stop of the
add-on the charger's 0 A goes out before the batteries go to 0 W, for at
most 15 seconds; if the charger does not take it, the notice *Car may still
be charging* follows.
+36 -12
View File
@@ -64,6 +64,8 @@ PHASE_GAP_S = 600.0 # at most one phase switch per this
WRITER_S = 30.0 # a differing read-back this long is another writer
RETRY_S = 60.0 # a write the charger did not take, tried again after
MAX_TRIES = 3 # ... this many times, then it waits for the user
STUCK_BACKOFF_FIRST_S = 900.0 # Solar under a stuck verdict, its starts used
STUCK_BACKOFF_S = 1800.0 # up: one more after 15 min, then every 30 min
TOL_A = CH.TOOK_TOL_A
@@ -717,6 +719,8 @@ class SolarWriter(ManualWriter):
self.other_at = None # C6: Manual's latest non-zero write
self.on_owed = None # C1: told when an own 0 A is out / back
self.stuck_starts = 0 # SPIKE-06 C12: starts under one stuck verdict
self.stuck_wait = None # ... used up: the next start not before
self.stuck_warned = False # ... and its one CHARGER_REFUSED was given
def owe_start(self) -> None:
"""C1: the add-on starts in Off while an exit 0 A of its own was still
@@ -724,6 +728,15 @@ class SolarWriter(ManualWriter):
so the 0 A is owed (once it may write), retried by the exit rule."""
self.start_owed = self.engaged = True
def _stuck_end(self) -> None:
"""SPIKE-06: a stuck episode ends (the reading followed a start, a
press of Solar, Off, Manual or shadow): starts counted afresh, and
its CHARGER_REFUSED is cleared."""
if self.stuck_warned:
self.gave_up = False
self.stuck_starts, self.stuck_wait = 0, None
self.stuck_warned = False
def _owed(self, pending: bool) -> None:
if self.on_owed is not None:
self.on_owed(pending)
@@ -758,7 +771,7 @@ class SolarWriter(ManualWriter):
held = self.hold or self.mismatch_since is not None
super().user_changed()
self.gave_up, self.fails, self.fail_at = False, 0, None
self.stuck_starts = 0
self._stuck_end()
if held:
self.last_a = None
self.sent_a, self.taken = None, True
@@ -772,6 +785,8 @@ class SolarWriter(ManualWriter):
zero = float(a) <= TOL_A
if not zero and tracker is not None and tracker.stuck(now):
self.stuck_starts += 1 # C12: a start under a stuck verdict
if self.stuck_wait is not None:
self.stuck_wait = now + STUCK_BACKOFF_S # a backoff try
if zero:
self.zero_at = self.zero_sent_at = now
self._owed(True) # C1: kept with the mode until back
@@ -1007,6 +1022,7 @@ class SolarWriter(ManualWriter):
self._adopt(cur) # round 9: a late read-back
self._mark(r, now)
if mode != SOLAR:
self._stuck_end()
self.would = None
if mode == OFF and self.start_owed:
if not writing:
@@ -1026,6 +1042,7 @@ class SolarWriter(ManualWriter):
else self.plan.n
n_now = 1 if self.single else n_real
if not writing:
self._stuck_end()
# Shadow, Stop, a safety stop, stopping: the way-out 0 A while
# owed, then nothing. The watch goes on (another writer is held
# for every reader) and so does the plan, for the card.
@@ -1041,24 +1058,31 @@ class SolarWriter(ManualWriter):
fault = ("error" if (r.error or r.state in ("E", "F")) else
"stuck" if stuck else None)
if not stuck:
if self.stuck_starts >= MAX_TRIES and self.gave_up:
self.gave_up = False # the reading moved: start afresh
self.stuck_starts = 0
self._stuck_end() # the reading moved: start afresh
if fault == "stuck" and not self.live:
# SPIKE-06 C12/C14 (option 2): no current of Solar's own may stand
# (its own 0 A stands, or Solar was just chosen), so a stuck
# verdict no longer holds the car: Solar's normal step writes its
# 0 A first over a current that is not its own, then the start
# rule. A start moves the reading (the verdict clears) or is not
# taken: then the 0 A again, and after MAX_TRIES such starts under
# one verdict, CHARGER_REFUSED and the 0 A stands (EV-04's rule).
# rule. A start moves the reading (the episode ends) or is not
# taken: then the 0 A again. After MAX_TRIES such starts, one
# CHARGER_REFUSED, then one more start after 15 min and one every
# 30 min (PM decision): a fault that clears is found again.
if self.stuck_starts < MAX_TRIES:
fault = None
elif not self.gave_up:
self.gave_up = True
_LOG.warning("The charger did not take the current, so the "
"add-on stops asking until you press Solar: "
"CHARGER_REFUSED.")
else:
if self.stuck_wait is None:
self.stuck_wait = now + STUCK_BACKOFF_FIRST_S
if not self.stuck_warned:
self.stuck_warned = True
_LOG.warning("The charger did not take the current, so "
"the add-on tries again in 15 min, then "
"every 30 min: CHARGER_REFUSED.")
if now >= self.stuck_wait:
self.gave_up = False
fault = None
else:
self.gave_up = True
if fault is not None:
# 0 A while owed, then no write until it clears; then the start
# rule. A stuck reading cannot confirm the 0 A.
+6
View File
@@ -240,6 +240,12 @@ check(f"T28 (b): frozen at 0 A, then Solar starts (the write unconfirmed): "
bool(st28) and [x for x in w28b if x[0] >= st28[0]][:1]
and [x for x in w28b if x[0] >= st28[0]][0][1] == 0.0
and r28b["sim"].setpoint_a == 0.0)
# SPIKE-06 (PM): under the verdict at most MAX_TRIES starts, then the backoff
# (15 min, then 30 min; test_ev20_rig.py): no 72 s flapping.
s28b = [t for t, a, _ in w28b if a > 0.0 and st28 and t >= st28[0]]
check(f"T28 (b): at most {carmode.MAX_TRIES} starts under the verdict in the "
f"run, then none before the 15 min backoff ({s28b})",
len(s28b) <= carmode.MAX_TRIES)
# T29: the charger unavailable 300-420 s.
T29 = {"i": lambda p, c: None,
+85 -33
View File
@@ -344,39 +344,91 @@ for race in (False, True):
and r["trace"][-1]["fault"] is None)
nevers(r, f"C12 [race={race}]")
# C12's bound: a charger whose reading is really frozen. Solar's own 0 A
# stands (the frozen read-back shows 0 A), so the start rule runs; each start
# write is not taken and the 0 A follows. At most MAX_TRIES starts under one
# verdict, then ONE CHARGER_REFUSED warning and the 0 A stands (EV-04: until
# Solar is pressed). Here the reading comes back at 1200 s with the very
# values it froze with (0 W, 0 A), so nothing moves; pressing Solar at 1250 s
# starts afresh.
n0 = LOG.mark()
r = S.drive(const(600.0), lambda t: 600.0 + (1000.0 if 200 <= t < 330
else 2300.0 if t < 200
else 6000.0),
dur=1500, first="car", socs={"a": 100.0, "b": 100.0},
opts={"ev_pause_min": 1, "ev_start_min": 1},
events={300: lambda p, c: p.ch.freeze(),
1200: lambda p, c: p.ch.freeze(False),
1250: act("car_mode", "solar")})
r["_log"] = n0
w = cur_writes(r)
st = [x["t"] for x in r["trace"] if x["fault"] == "stuck"]
t0 = nth(st, 0) if st else 0.0
starts = [t for t, a, _ in w if a > 0.0 and t0 <= t < 1200]
warn = [m for m in LOG.since(n0, "WARNING") if "CHARGER_REFUSED" in m]
after = [(t, a) for t, a, _ in w if t >= 1200]
quiet = [(t, a) for t, a in after if t < 1250]
check(f"C12 bound: a frozen charger after Solar's own 0 A: at most 3 starts "
f"under the verdict ({starts}), one CHARGER_REFUSED ({len(warn)}), the "
f"charger at 0 A, nothing written until Solar is pressed, then a start "
f"within the start rule ({after[:2]})",
bool(st) and 1 <= len(starts) <= carmode.MAX_TRIES and len(warn) == 1
and not quiet and present(nth(after, 0)) and nth(after, 0)[1] > 0.0
and nth(after, 0)[0] <= 1250 + 75
and [a for t, a, _ in w if t0 <= t < 1200][-1:] == [0.0])
nevers(r, "C12 bound")
# C12's cap and backoff (PM decision): a charger whose reading is really
# frozen (at 300 s, with the values it will show when it comes back). Solar's
# own 0 A stands, so the start rule runs; each start is not taken and the 0 A
# follows. At most MAX_TRIES starts under one verdict, then ONE
# CHARGER_REFUSED; then one more start 15 min later, then one every 30 min
# (each by the start rule), never the 72 s flapping.
def frozen_run(dur, events=None):
n0 = LOG.mark()
ev = {300: lambda p, c: p.ch.freeze()}
ev.update(events or {})
r = S.drive(const(600.0), lambda t: 600.0 + (1000.0 if 200 <= t < 330
else 2300.0 if t < 200
else 6000.0),
dur=dur, first="car", socs={"a": 100.0, "b": 100.0},
opts={"ev_pause_min": 1, "ev_start_min": 1}, events=ev)
r["_log"] = n0
st = [x["t"] for x in r["trace"] if x["fault"] == "stuck"]
t0 = nth(st, 0) if st else 1e9
w = cur_writes(r)
starts = [t for t, a, _ in w if a > 0.0 and t >= t0]
warn = [m for m in LOG.since(n0, "WARNING") if "CHARGER_REFUSED" in m]
return r, w, starts, warn
r, w, starts, warn = frozen_run(4000)
first3, later = starts[:3], starts[3:]
t3 = nth(first3, 2)
gaps = [b - a for a, b in zip(later, later[1:])]
check(f"cap: a frozen charger: 3 starts under the verdict ({first3}), then "
f"one CHARGER_REFUSED ({len(warn)})",
len(first3) == carmode.MAX_TRIES and len(warn) == 1
and all(b - a < 120 for a, b in zip(first3, first3[1:])))
check(f"backoff: one more start 15 min after the 3rd (+ the start rule), "
f"then one every 30 min (+ the start rule): {later} (gaps {gaps})",
present(t3) and len(later) == 2
and 900 <= nth(later, 0) - t3 <= 900 + 80
and all(1800 <= g <= 1800 + 80 for g in gaps))
nevers(r, "cap and backoff")
# Recovery: the reading comes back at 1200 s with the values it froze with,
# so nothing moves by itself; the next backoff start is taken, the reading
# follows it, the episode ends (warning cleared) and the car charges.
r, w, starts, warn = frozen_run(2400, {1200: lambda p, c: p.ch.freeze(False)})
t3 = nth(starts, 2)
rec = [t for t in starts if t > 1200]
check(f"recovery: the fault clears at 1200 s; the next backoff start "
f"({rec[:1]}, 15 min after the 3rd at {t3}) is taken and the car "
f"charges to the end, warning cleared, not stuck",
present(nth(rec, 0)) and present(t3)
and 900 <= nth(rec, 0) - t3 <= 980
and r["sim"].power_w > 1000.0 and not r["c"].car.stuck_now
and not r["c"].car_solar.gave_up)
nevers(r, "recovery")
# A press of Solar during the backoff starts the episode afresh: a start by
# the start rule after the press, not 15 min later.
r, w, starts, warn = frozen_run(1400, {1000: act("car_mode", "solar")})
after = [t for t in starts if t >= 1000]
check(f"press: Solar pressed at 1000 s during the backoff: a start by the "
f"start rule after the press ({after[:1]})",
present(nth(after, 0)) and nth(after, 0) <= 1000 + 75)
# The episode ends on Off, Manual and shadow: counter, wait and warning
# cleared (read 5 s after the switch).
for name, fn in (("Off", act("car_mode", "off")),
("Manual", act("car_mode", "manual")),
("shadow", lambda p, c: c.o.__setitem__("shadow_mode",
"on"))):
seen = {}
def look(p, c, seen=seen):
sw = c.car_solar
seen.update(starts=sw.stuck_starts, gave_up=sw.gave_up,
wait=getattr(sw, "stuck_wait", None),
warned=getattr(sw, "stuck_warned", None))
before = {}
def look0(p, c, before=before):
before.update(starts=c.car_solar.stuck_starts,
gave_up=c.car_solar.gave_up)
r, w, starts, warn = frozen_run(900, {790: look0, 800: fn, 805: look})
check(f"episode end on {name}: before {before}, after {seen}",
before.get("starts") == carmode.MAX_TRIES and before.get("gave_up")
and seen.get("starts") == 0 and seen.get("gave_up") is False
and seen.get("wait") is None and seen.get("warned") is False)
# C14: Manual's refused writes leave a stuck verdict on a paused, live car,
# then the user presses Solar. No current of Solar's own may stand, so the