SAFETY-87: peak guard uses every battery that can still give
At N>=2 a battery at or under its own peak reserve is held: it gives nothing for the peak (weight 0 while the site gives) and the guard's need is placed on the live, non-refusing batteries above theirs. The guard is floor-limited, and alarms, only when those cannot hold the limit at full power for ALARM_HOLD_S. The peak alarms no longer read "Not ready" or hold the Home page at 0 W, because control keeps running. N=1 is byte-identical. DECISIONS/SAFETY-87-guard-uses-able-batteries.md. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
This commit is contained in:
@@ -635,7 +635,7 @@ def site_resolve(claims: list) -> Resolution:
|
||||
|
||||
|
||||
def resolve(claims: list, *, units=None, weights=None, live=None,
|
||||
tick=None) -> Resolution:
|
||||
tick=None, reserve=()) -> Resolution:
|
||||
"""The three stages, in order, over one cycle's claims.
|
||||
|
||||
`units` is the site's roster of inverters. Left None it is derived from the
|
||||
@@ -737,6 +737,13 @@ def resolve(claims: list, *, units=None, weights=None, live=None,
|
||||
gate, held = _unit_modes(out, site_claims, bounds, live)
|
||||
if callable(weights):
|
||||
weights = weights(out.target_w)
|
||||
# SAFETY-87: units under their peak reserve weigh 0 while the site gives,
|
||||
# so the others carry the peak floor. An Off battery gives the peak's
|
||||
# shortfall, so it goes before them when no other unit is left.
|
||||
reserve = set(reserve) if out.target_w > 0.0 else set()
|
||||
if held and reserve and not set(bounds) - held - reserve:
|
||||
held = set()
|
||||
held = held | reserve
|
||||
if held:
|
||||
weights = {u: (0.0 if u in held else
|
||||
(1.0 if weights is None else weights.get(u, 1.0)))
|
||||
|
||||