SAFETY-87: peak guard uses every battery that can still give
At N>=2 a battery at or under its own peak reserve is held: it gives nothing for the peak (weight 0 while the site gives) and the guard's need is placed on the live, non-refusing batteries above theirs. The guard is floor-limited, and alarms, only when those cannot hold the limit at full power for ALARM_HOLD_S. The peak alarms no longer read "Not ready" or hold the Home page at 0 W, because control keeps running. N=1 is byte-identical. DECISIONS/SAFETY-87-guard-uses-able-batteries.md. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
This commit is contained in:
@@ -3157,6 +3157,10 @@ and what to do:
|
||||
- **A battery cut-out level is not known.** Fill in “Battery cut-out level”
|
||||
for each inverter in the settings.
|
||||
|
||||
With several inverters, a battery at its peak reserve does not give for the
|
||||
peak and the others do. This alarm then comes only when the others cannot
|
||||
keep the period under the limit alone. Control keeps running meanwhile.
|
||||
|
||||
The peak reserve only applies to keeping the peak down. Normal home use can
|
||||
still draw the battery below it, down to the battery cut-out level, where the
|
||||
battery switches itself off.
|
||||
@@ -3252,7 +3256,9 @@ state of charge is unread, or when an inverter's `bms_soc_floor` (label
|
||||
“Battery cut-out level”) is missing, because the reserve is graded against it.
|
||||
Charging from the grid stays blocked meanwhile. With several inverters the
|
||||
notification names the battery at its limit (SAFETY-32), each graded against
|
||||
its own cut-out level. ⚠️ **The reserve binds the peak guard only
|
||||
its own cut-out level. That battery is held (weight 0 while the site gives)
|
||||
and the guard's need goes to the others, up to their rating; the alarm fires
|
||||
only if they miss the limit at full power for `ALARM_HOLD_S` (SAFETY-87). ⚠️ **The reserve binds the peak guard only
|
||||
(SAFETY-25).** Self-consumption has no such floor. See *What `peak_soc_floor`
|
||||
does not protect*.
|
||||
|
||||
@@ -3390,7 +3396,7 @@ for a new install*.
|
||||
| Meter reading may be stuck | See *Meter reading may be stuck* under Notifications. |
|
||||
| Month peak | This month's highest 15-minute average, when it happened, and how close it is to your peak limit. Amber from 80 %. |
|
||||
| 15-minute periods measured this month | How many 15-minute periods the add-on has measured and saved this month. |
|
||||
| Peak guard, Load too high for battery, Battery at its peak reserve | What the add-on does to keep your peak down. *Idle, heading for …* is where this 15-minute period is heading. *Waiting for meter readings* after a restart means the battery does not charge until the add-on can measure the period again. |
|
||||
| Peak guard, Load too high for battery, Battery at its peak reserve | What the add-on does to keep your peak down. *Idle, heading for …* is where this 15-minute period is heading. *Waiting for meter readings* after a restart means the battery does not charge until the add-on can measure the period again. A red peak row is an alarm while control keeps running, so the banner shows its title without *Not ready*. |
|
||||
| Battery level, Battery power, Grid power | The reading of that entity. *No usable reading* means the entity is missing, or its reading is too old. Check it in Developer Tools before replacing it. |
|
||||
| Inverter control | Whether the inverter can be controlled, and how much it can charge and give. |
|
||||
| *name*: battery power reading stopped changing | The reading did not change while the add-on asked for a change. It may be stuck, or the battery may be refusing. The add-on sets the inverters to 0 W until it changes. |
|
||||
|
||||