SAFETY-87: peak guard uses every battery that can still give
At N>=2 a battery at or under its own peak reserve is held: it gives nothing for the peak (weight 0 while the site gives) and the guard's need is placed on the live, non-refusing batteries above theirs. The guard is floor-limited, and alarms, only when those cannot hold the limit at full power for ALARM_HOLD_S. The peak alarms no longer read "Not ready" or hold the Home page at 0 W, because control keeps running. N=1 is byte-identical. DECISIONS/SAFETY-87-guard-uses-able-batteries.md. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
This commit is contained in:
@@ -69,6 +69,8 @@ which does not run the startup gate) the absence costs a shave and never a pack.
|
||||
|
||||
## 3. DECISION 2 — the site verdict is the MAXIMUM of the packs' own floors
|
||||
|
||||
*At N>=2 one pack at its floor no longer stops the others: [[SAFETY-87]].*
|
||||
|
||||
`Controller.pack_floor_soc` — the **minimum** measured SoC, the emptiest pack —
|
||||
**is unchanged**, exactly as the card instructed. What changed is the floor it is
|
||||
graded against. `peakguard.binding_soc_floor()` reduces the roster's per-pack
|
||||
|
||||
@@ -0,0 +1,73 @@
|
||||
# SAFETY-87 - the peak guard uses every battery that can still give
|
||||
|
||||
**Status: DECIDED 2026-10-01 (owner card).** Follows SAFETY-86's "Not
|
||||
changed" list. Tests: `test_safety87.py`; identity:
|
||||
`tools/safety87_identity.py`.
|
||||
|
||||
**The defect.** At N>=2 the guard graded the emptiest battery against the
|
||||
highest floor ([[SAFETY-32]] §3). One battery under `peak_soc_floor` made the
|
||||
whole site floor-limited: the claim asked for 0 W and the reserve alarm fired,
|
||||
even with the other battery full. Measured: a maintenance charge (A at 11 %)
|
||||
raised the alarm 10 times while both batteries gave 2000 W and the quarter
|
||||
landed on the aim (SAFETY-84 rig test, check 3); a HOLD (A at 99 %, B at
|
||||
15 %) left A at 0 W and banked 4051 W, raising the month peak (SAFETY-86
|
||||
review; rig case 7a: 4563.8 W).
|
||||
|
||||
**The fix.**
|
||||
- `decide()` and its call are unchanged. At N>=2 `Controller._peak_on_able()`
|
||||
then grades each battery on its own floor (`peakguard.reserve_split()`).
|
||||
One at or under it is *held*. The others that are live and not refusing
|
||||
(SAFETY-73) are *able*.
|
||||
- A floor-limited decision is re-taken on the able batteries
|
||||
(`peakguard.place_on_able()`): their own permission (min SoC against max
|
||||
floor, among them), and a floor of `min(need, able_w)`. `able_w` is their
|
||||
rating plus the drain a held battery gives anyway (its maintenance pin).
|
||||
- The held batteries weigh 0 in the split while the site gives
|
||||
(`arbiter.resolve(reserve=)`), so the floor lands on the able ones. During a
|
||||
HOLD, a held battery is not counted among the "others" (`_peak_over_hold()`),
|
||||
so the holding battery covers the need.
|
||||
- Floor-limited now means: some battery is held and the able ones cannot hold
|
||||
the aim. The claim still asks them for `able_w`. The alarm fires only if
|
||||
they miss the real limit at full power for `ALARM_HOLD_S`, the same test as
|
||||
'Load too high' (`_reserve_short()`), so a one-cycle miss at a quarter's end
|
||||
is not an alarm. With nothing able (all held, or the rest refusing or
|
||||
dropped) it is the old state: 0 W, immediate alarm.
|
||||
- The alarm and the row name `held`, each battery graded on its own floor. The
|
||||
old code named batteries against the site's highest floor.
|
||||
- Page: the two peak rows carry `runs`. A red `runs` row gives the banner its
|
||||
title without "Not ready", and the Home page is not shown as held at 0 W.
|
||||
Rows that do stop control still outrank it.
|
||||
|
||||
**How SAFETY-32's concern is still covered.** SAFETY-32 took min(SoC) against
|
||||
max(floor) so the guard never sizes a forced discharge a battery's own BMS
|
||||
stops. Now no battery at or under its own floor is asked for the peak: it is
|
||||
graded on its own floor, and an unread SoC or unknown cut-out counts as held.
|
||||
The min/max pairing still decides permission, over the able batteries. The
|
||||
roster verdict `decide()` echoes (`soc`, `soc_floor`) is kept, so SAFETY-32's
|
||||
call-site and reduction checks still bite. What changed is only that one held
|
||||
battery no longer stops the others.
|
||||
|
||||
**Before -> after** (test_safety87.py, rig of 2 x 2500 W, aim 3450 W):
|
||||
|
||||
| case | before | after |
|
||||
|---|---|---|
|
||||
| charge, A 11 %, house 4500 | 3 reserve alarms, quarter 3450 | 0 alarms, 3450 |
|
||||
| HOLD, A 99 % / B 15 %, house 5500 | A 0 W, B 2488 W, 3 alarms | A 2054 W, B 0 W, 0 alarms, 3450 |
|
||||
| HOLD, house 6500 | A 0 W, B 2488 W, 4051 W | A 2500 W, B 0 W, 4014 W, 1 alarm (A alone is short) |
|
||||
| HOLD, month peak 4000, house 6000 | A 0 W, B 2488 W, 3551 W, alarms | A 2054 W, B 0 W, 3950 (peak - margin), 0 alarms |
|
||||
| both under the reserve | alarm | alarm (unchanged) |
|
||||
| N=1, every scenario | | byte-identical |
|
||||
|
||||
**Open, for the owner.**
|
||||
- The loop still draws a held battery (SAFETY-25 option A: the reserve binds
|
||||
the peak guard only). It gives last, after the able ones. So with house 6500
|
||||
in the charge case, B alone cannot hold the aim, the alarm fires as
|
||||
specified, and the loop then lands the quarter on the aim from A. The text
|
||||
says "cannot keep … alone", not "will go over", so it stays true.
|
||||
- Battery modes on, A Off and B held: when B alone can place the floor, OPT-11
|
||||
keeps A resting and B gives it. When B cannot, A gives first. Making Off give
|
||||
before a held battery in the first case needs a third allocator tier.
|
||||
- The notification and row text live in `messages.py`, which has no NL layer
|
||||
yet (UX-19). The Home page text, which has NL, is unchanged.
|
||||
|
||||
**Not changed.** N=1. 'Load too high' (SAFETY-81). SAFETY-85, -88, -89, -90.
|
||||