UX-08 phase 2b: short, plain status rows and page banners
checks / unit (pull_request) Successful in 8m47s
infra-pin / fresh (pull_request) Failing after 1s

Every Commissioning row and every page banner is now worded in
app/messages.py (row_*, banner_*): one sentence of at most 15 words, a red
row up to three sentences so a latch still says how it clears, banners at
most 12 words. No row names a Home Assistant entity: sensors by their
setting, solar sources by their place in the list. Reason codes and limits
stay on the log line and event list; rows keep the numbers a reader acts on.

UX-07 item 1: ClampWatchdog counts over-rating and integrator-bound
engagements separately, and after an episode each count shows under its own
alarm's title instead of both under "output clamp".

No row colour, visibility or banner order changed. Rows carry an "id" so the
tests pin meaning rather than wording. The row and banner kinds leave the
allowlist (200 -> 168, cap equal). DOCS.md gains "Status page"; choices are in
DECISIONS/UX-08-short-notifications.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
This commit is contained in:
2026-09-27 02:12:10 +02:00
co-authored by Claude Opus 5.5
parent 48ef06ac1f
commit d017fc67bf
19 changed files with 989 additions and 578 deletions
+8 -6
View File
@@ -811,9 +811,11 @@ check("...and the status page shows BOTH per-inverter rows - one latched, one "
"'the sign watchdog is armed' printed over a latched sibling is the page "
"lying",
len([r for r in _c3r.checks()
if r["text"].startswith("sign watchdog [")]) == 1
if r.get("id") == "direction" and r["ok"]
and "inverter-a" in r["text"]]) == 1
and len([r for r in _c3r.checks()
if "SIGN-DISAGREEMENT FAILSAFE [" in r["text"]]) == 1)
if r.get("id") == "direction" and not r["ok"]
and not r["warn"] and "inverter-b" in r["text"]]) == 1)
check("⚠️ AND SAFETY-30's SITE ROW IS THERE BESIDE THEM, EXACTLY ONCE. At two "
"inverters there are three sign questions on this page and they are three "
"rows: is A doing what it was told, is B, and is the SITE'S TOTAL "
@@ -823,15 +825,15 @@ check("⚠️ AND SAFETY-30's SITE ROW IS THERE BESIDE THEM, EXACTLY ONCE. At tw
"per-unit rows would be advertising two guards where the install has "
"three",
len([r for r in _c3r.checks()
if r["text"].startswith("site sign watchdog:")]) == 1)
if r.get("id") == "site_direction"]) == 1)
check("...and the per-inverter rows now say WHAT the unit was compared "
"against, because at a roster of two it is no longer the meter. A row "
"still reading 'the command opposed the meter' would send an operator to "
"look at P1 for a fault that is visible only on one inverter's own power "
"sensor",
all("its own measured power" in r["text"] for r in _c3r.checks()
if r["text"].startswith(("sign watchdog [",
"SIGN-DISAGREEMENT FAILSAFE ["))))
len([r for r in _c3r.checks() if r.get("id") == "direction"]) == 2
and all("its own power" in r["text"] for r in _c3r.checks()
if r.get("id") == "direction"))
# The operator's clear, which is one button and has to reach every latch.
run(_c3r.handle_action("auto_toggle")) # -> stopped